RZRong Zhou

Rong Zhou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rong Zhou has a total of 65 co-authors. Here are the top co-authors by number of shared publications:

  • J. Zhang

    College of physics, Sichuan University, Chengdu 610065, China

    4 shared publications
  • F. Shen

    College of physics, Sichuan University, Chengdu 610065, China

    3 shared publications
  • J. Zuo

    Sichuan Univ, Coll Phys, Dept Nucl Engn & Technol, Wangjiang Campus, Chengdu 610065, Peoples R China

    3 shared publications
  • S. Hu

    Sichuan Univ, Coll Phys, Dept Nucl Engn & Technol, Wangjiang Campus, Chengdu 610065, Peoples R China

    3 shared publications
  • S. Zhang

    Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, CAS, Beijing 100049, China

    3 shared publications
  • X. Zhang

    Sichuan Univ, Coll Phys, Dept Nucl Engn & Technol, Wangjiang Campus, Chengdu 610065, Peoples R China

    3 shared publications

Latest Publications

  • Areal density measurement of overlapping materials based on a photon-counting detector

    by Zhe Su, Rong Zhou, Wei Shen, Dejia Ding, Shu Sun, Shuaibin Ding, Qingbao Fu

    Accurate quantification of areal density in overlapping thin-film materials is essential for evaluating and controlling the performance of multilayer electrodes in lithium-ion batteries. In this study, a dual-energy X-ray absorptiometry method based on a silicon pixel photon-counting detector (PCD) is proposed to simultaneously measure the areal densities of two overlapping materials. By utilizing the adjustable electronic thresholds of the MPI501 PCD, the incident X-ray spectrum is divided into two optimized energy intervals, determined through Nordfors, NSR Δ t , and SNR criteria. Monte Carlo simulations conducted in Geant4 were employed to optimize detector thresholds, while experimental verification was performed using LiFePO 4 (LFP) and LiNi 0.8 Co 0.1 Mn 0.1 O 2 (NMC) multilayer electrodes. Under a 20 kV X-ray tube voltage and detector thresholds set to 4 keV and 8 keV, the proposed method achieved mean standard deviations of 1.25 g/m 2 for LFP and 0.67 g/m 2 for NMC, with RMSE values below 2.5 g/m 2 . The results confirm the feasibility of this non-destructive technique for high-precision areal density measurement.


  • Open Access

    Corrigendum: Radioactivity and space range of ultra-low-activity for in vivo off-line PET verification of proton and carbon ion beam—a phantom study

    by Fuquan Zhang, Junyu Zhang, Yan Lu, Yixiangzi Sheng, Yun Sun, Jiangang Zhang, Jingyi Cheng, Rong Zhou

    In vivo biological verification using positron emission tomography (PET) is one of the most important estimation methods in proton or heavy ion precision radiotherapy (1)(2)(3)(4). Models of in vivo biological verification using PET can be classified into three types: in-beam, in-room and off-line. In-beam and off-line methods are most frequently used in research studies and clinical practice to evaluate the precision of proton or heavy ion beam. The in-beam PET is an ensemble of PET and particle radiotherapy terminals that can gather the β+ signal throughout particle beam delivery. In-beam imaging is little influenced by human metabolism and blood flow, and it can increase measurement accuracy (5)(6)(7). In-room PET uses a stand-alone and full-ring PET scanner positioned in the treatment room to scan the patient (still in the treatment bed) soon after treatment. In-room PET is a compromise between in-beam and off-line PET (8). The off-line PET is more applicable: patients are transferred to the PET/CT equipment room for gathering of the β+ signal after particle beam delivery (9,10).Compared with the in-beam PET, the off-line PET has several advantages such as much lower cost, shorter treatment time, and increased suitability for clinical practice (11,12). Offline PET offers a practical and easy-to-implement method of treatment verification for particle radiotherapy centers with PET/CT scanners located near their treatment rooms. In particle therapy, the detectable activation results from nuclear fragmentation reactions between the projectiles and the target nuclei of the traversed tissue. Proton-induced radioactivity is thus very sensitive to the elemental composition. These sources of uncertainty are reduced in the off-line scenario because of the small number of production channels that yield long-lived positron emitters (13,14). Because of these two prominent advantages, off-line PET has achieved wide recognition in clinical practice.In practice, the β+ signal of acquisition in off-line PET is mainly emitted by 11 C (20.39 min). However, there is a 10min interval between beam delivery and PET acquisition, which can also cause large reductions in radioactivity. PET image quality (radioactivity and beam range) is compromised when the interval time of off-line PET is too long. The radioactivity in the tumor of off-line PET imaging is 37-370 Bq/mL, which is far below the level of conventional 18 FDG (fluorodeoxyglucose) PET/CT imaging (over 7,400 Bq/mL) (15). In clinical practice, the mean radioactivity of 289 Bq/mL in proton radiotherapy for breast cancer has been obtained by calculating the radioactivity of each spot within the target area. The average radioactivity of carbon ion radiotherapy in the anterior gland, liver and head tumors were 90.65, 109.89, and 138.75 Bq/mL, respectively. Hence, whether radioactivity and space range of off-line PET at ultra-low-activity (ULA) is reliable needs further verification.The radioactivity and space range of commercial offline PET acquisitions based on ULA should be evaluated accurately to guarantee the reliability of clinical verification. The purpose of this study is to quantify the radioactivity and space range of off-line PET acquisition by simulating the ULA triggered by proton and heavy ion beam using verification phantom.The PET-CT device used in this research was a Biograph mCT PET/CT scanner (Siemens Medical Solutions USA), which has four rings of 192 blocks in total, each of which contains 13 × 13 lutetium-oxyorthosilicate (LSO) crystals with dimensions of 4 × 4 × 20 mm. The voltages of the X-ray tube in CT were 80, 100, 120, and 140 kV, respectively. The planar resolution of the reconstruction image was 4 × 4 mm, and its thickness was 0.6 mm. The PET detection system had four detection rings, each of which contained 48 detection blocks. Each detection block was uniformly divided into 13 × 13 basic detection units, and the crystal size of each detection unit was 4 × 4 × 20 mm. The aperture of the detector was 78 cm and the field of view of the detector's axial was 21.8 cm. The detector's gating window was 4.1 ns and its energy window was 435-650 keV. We used the Truex image reconstruction algorithm which incorporates OSEM (Ordered Subsets Expectation) iterative algorithm and pointspread-function correction. CT attenuation correction is used in image reconstruction.Using a PET validation phantom (Flanged Jaszczak ECT Phantom), referring to the National Electrical Manufacturers Association (NEMA) standard, we simulated the ULA of the target after beam delivery. The phantom was cylindrical in shape, its external height was 22.24 cm, its bottom diameter was 19.24 cm, its wall thickness was 3.2 mm, and the material was PTFE. As shown in Figure 1A, six cylindrical containers of the same height were arranged in a ring inside the phantom. Their diameters were 8 mm (No. 1), 12 mm (No. 2), 16 mm (No. 3), and 25 mm (Nos. 4, 5, and 6), and their height was 38.1 mm. Thus, the cylinders' volumes were 1.92 ml (No. 1), 4.31 ml (No.2), 7.66 ml (No. 3), and 18.70 ml (Nos. 4, 5, and 6). During the loading of radiopharmaceuticals into the container, small bubbles often appeared inside the small containers, so we chose the larger containers. The containers (Nos. 4 and 6) were selected as the research objects because of their large volumes and reduced bubble effects.The ULA of the experimental design was 11.1-1,480 Bq/mL. Smaller radioactivity would lead to a greater error when measuring activity. Because the measurement error of highactivity radiopharmaceuticals is small, to obtain accurate values for the activity during the measurements, the active compounds were filled into the containers 10 half-lives in advance. The radioactivity of radiopharmaceuticals was measured by the radio activity meter CRC-25R with resolution of 0.01 MBq. The radiopharmaceutical ( 18 F-FDG) at the dose of 27.09 MBq was...

  • Open Access

    Temperature Peak-Drift Correction Method for NaI(Tl) Detectors Using the Background Peak

    by Songlin Wen, Rong Zhou

    The overall gain of a scintillation detector is temperature-dependent, leading to a drift in the measured gamma energy spectrum with changes in temperature. To mitigate this effect, a temperature drift correction is essential prior to conducting gamma spectrum analysis. In this study, the detector gain ratio is determined by comparing the positions of the same background peak across different spectra. Subsequently, the original spectrum is adjusted accordingly to obtain a gamma spectrum free from temperature drift. Experimental results demonstrate that after implementing this correction, the relative deviation of the 57Co characteristic peak positions in the gamma spectrum measured by the NaI(Tl) detector is reduced from 18.64% to 0.91%. Furthermore, by performing energy calibration beforehand, the characteristic peak position can be utilized for secondary correction, further minimizing temperature drift. Our findings indicate that the relative deviation of the 22Na characteristic peak positions was reduced, respectively, to 0.51% and 0.46% through secondary correction. This approach, which utilizes the background peak for correction, avoids the need for additional radioactivity or circuitry and effectively mitigates peak drift. Overall, this method holds significant implications for enhancing the accuracy of gamma spectrum analysis.


  • Open Access

    Establishing the function relationship between time spectrum and proton range in proton therapy through Monte Carlo simulation

    by Yibo He, Xin Tong, Yuhan Li, Jingyi Cheng, Rong Zhou

    To validate range shifts in proton therapy, we investigated the potential of using the temporal information of prompt gamma rays as an indicator. We simulated the proton transport process using Monte Carlo simulations and used a geometric scorer to obtain the location and timing of prompt gamma ray production. By using a homogeneous target material in the simulation model, we established a fitted relationship between the range of 90–210 MeV protons and the corresponding temporal spectral width. Additionally, by introducing air cavities of 2–20 mm in simulations of inhomogeneous target materials, we observed significant correlations between the range offsets and the temporal spectral widths. These correlations were fitted to derive a functional relationship between the two variables.

  • Open Access

    Radioactivity and Space Range of Ultra-Low-Activity for in vivo Off-line PET Verification of Proton and Carbon Ion Beam—A Phantom Study

    by Fuquan Zhang, Junyu Zhang, Yan Lu, Yixiangzi Sheng, Yun Sun, Jiangang Zhang, Jingyi Cheng, Rong Zhou

    Purpose: The radioactivity induced by proton and heavy ion beam belongs to the ultra-low-activity (ULA). Therefore, the radioactivity and space range of commercial off-line positron emission tomography (PET) acquisition based on ULA should be evaluated accurately to guarantee the reliability of clinical verification. The purpose of this study is to quantify the radioactivity and space range of off-line PET acquisition by simulating the ULA triggered by proton and heavy ion beam.Methods: PET equipment validation phantom and low activity 18F-FDG were used to simulate the ULA with radioactivity of 11.1–1480 Bq/mL. The radioactivity of ULA was evaluated by comparing the radioactivity in the images with the values calculated from the decay function with a radioactivity error tolerance of 5%. The space range of ULA was evaluated by comparing the width of the R50 analyzed activity distribution curve with the actual width of the container with a space range error tolerance of 4 mm.Results: When radioactivity of ULA was >148 Bq/mL, the radioactivity error was 30 Bq/mL, the space range error was below 4 mm.Conclusions: Off-line PET can be used to quantify the radioactivity of proton and heavy ion beam when the ULA exceeds 148 Bq/mL, both in radioactivity and in space range.


  • A low-power preamplifier for resistive charge division position-sensitive neutron detectors

    by X. Zhang, S. Hu, J. Zuo, R. Zhou

    A low power preamplifier solution for use with the rs-p4-0332-203r4 resistive charge distribution neutron detectors is presented in this work. The effects of the ground input impedance caused by the chip and the ground signal undershoot caused by the blocking capacitance are evaluated via simulations. For reference, a reasonable parameter configuration in the structure of a passive filter is sufficient to suppress the effects of both the input impedance and the undershoot. The power per channel in the preamplifier is limited to a maximum of 39 mW. Finally, measurement resolution of 6.8 mm is obtained for the detector.


  • A digital system of acquisition and coincidence for SANS

    by S. Hu, X. Zhang, F. Shen, R. Zhou, J. Zuo

    We have developed multi-channel signal acquisition with a coincidence digital circuit for a two-dimensional detector array of the small-angle neutron scattering spectrometer (SANS) of the Institute of Nuclear Physical Chemistry at the Chinese Academy of Engineering Physics. This paper discusses how to determine such factors as the coincidence time window and program dead time according to the characteristics of the detector signal and how to correct the timer to realize the data coincidence. The whole system can support up to 192 analog channels connected to a fast analog-to-digital converter, supporting speeds of 50 MSPS for each channel managed by a field-programmable gate array (FPGA). The internal clock of the FPGA is 50 MHz and the time accuracy is 20 ns. Preliminary experiments are carried out and the results are presented and discussed. The whole design can fully meet the needs of the spectrometer.


  • Remote update solution for LHAASO wide field-of-view Cherenkov telescope array electronic readout system

    by Z. Liu, R. Zhou, S. Zhang, J. Zhang, F. Shen, Y. Li, J. Chen

    The wide field-of-view Cherenkov telescope array (WFCTA), which consists of 18 wide field telescopes, is one of the main detectors used in the Large High Altitude Air Shower Observatory (LHAASO) . The WFCTA collects Cherenkov light and fluorescence signals from cosmic ray showers and converts them into electrical signals that are then processed by an electronic system based on a field-programmable gate array (FPGA) for later physical analysis. The high altitude of the array and the difficulties involved in disassembling the electronics inside the telescope mean that an electronic remote update solution with high fault tolerance and simple operation is required. The proposed remote update solution for the LHAASO-WFCTA electronic readout system is based on Xilinx Multiboot and is intended to implement remote updates without appended circuits. When compared with other remote update solutions based on Multiboot, the solution used on the WFCTA saves numerous resources in the original FPGA program, eases the timing constraint burden, and enhances security. This solution has been successfully implemented and used in remote updating of FPGAs in the LHAASO-WFCTA several times.