Advances in EPR Dosimetry in Terms of Retrospective Determination of Absorbed Dose in Radiation Accidents
Author:
Open Access
- 1 December 2018
- journal article
- Published by Adam Mickiewicz University Poznan in Current Topics in Biophysics
- Vol. 41 (1) , 11-21
Abstract
The electron paramagnetic resonance measurements of dosimetric signals originating from radicals generated under the influence of ionizing radiation allow to determine the dose absorbed by the casualties of radiation accidents. The study material can consist of victim’s teeth, bones or nails. Also human hair and mineral glass from personal electronic devices, that people had in the moment of accident, are considered to be useful in dosimetry. Although X-band (9.4 GHz) spectrometers predominate, Q-band devices (34 GHz) enable to increase the sensitivity of measurements and reduce the size of specimens, whereas L-band machines (1.1 GHz) are suitable for in vivo dosimetry. The EPR tooth enamel dosimetry has been used many times to assess the cumulative radiation dose and health risk in people living in areas contaminated due to the radiation accidents and to determine the unknown absorbed doses in patients after the overexposures during radiotherapy treatment.Keywords
This publication has 68 references indexed in Scilit:
- Space Radiation: The Number One Risk to Astronaut Health beyond Low Earth OrbitLife, 2014
- Electron spin resonance (ESR/EPR) of free radicals observed in human red hair: a new, simple empirical method of determination of pheomelanin/eumelanin ratio in hairMagnetic Resonance in Chemistry, 2014
- Effects of water treatment and sample granularity on radiation sensitivity and stability of EPR signals in X-ray irradiated bone samplesRadiation Protection Dosimetry, 2014
- The role of disulfide bond formation in the structural transition observed in the intermediate filaments of developing hairJournal of Structural Biology, 2012
- Physical dosimetric reconstruction of a radiological accident due to gammagraphy equipment that occurred in Dakar and Abidjan in summer 2006Radiation Measurements, 2008
- EX vivo ESR measurements associated with Monte Carlo calculations for accident dosimetry: application to the 2001 Georgian accidentRadiation Protection Dosimetry, 2006
- EPR tooth dosimetry as a tool for validation of retrospective doses: an end-user perspectiveApplied Radiation and Isotopes, 2005
- High precision EPR dosimetry as a reference tool for validation of other techniquesApplied Radiation and Isotopes, 2004
- Mechanically induced EPR signals in tooth enamelApplied Radiation and Isotopes, 2001
- In Vivo Dosimetry by Electron Spin Resonance SpectroscopyHealth Physics, 1968