Comparison between the Efficiencies of sub-2 μm C18 Particles Packed in Narrow Bore Columns
- 3 February 2011
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (5) , 1547-1556
Abstract
The chromatographic performance of two types of core−shell particles and two fully porous particles packed in 2.1 ID × 50 mm columns was investigated. Comparisons of the performances of the EiS-150-C18 to that of the Kinetex-1.7 μm-C18, Acquity-BEH-1.7 μm-C18, and Zorbax-XDB-1.8 μm-C18 are made and discussed. The physical factors that govern the performance of these columns, such as particle size distribution and column external, total, and particle porosity of the C18 packing materials were among the prime foci of investigation. The differences in the mass transfer behavior measured using naphtho[2,3-a]pyrene between these columns provides an indication of improved performance of the new EiS-150-C18 column. The minimum reduced height equivalent to a theoretical plate (HETP) value for the EiS-150-C18, hmin = 1.95, was achieved and was comparable to that obtained from the C18 phases of the Kinetex (hmin = 2.53), the Acquity (hmin = 2.26), and the Zorbax (hmin = 2.57) columns. This study reveals the importance of the dimension of the shell thickness in controlling the performance of columns packed with shell particles in narrow bore columns.Keywords
This publication has 25 references indexed in Scilit:
- Impact of retention on trans‐column velocity biases in packed columnsAIChE Journal, 2009
- Influence of Viscous Friction Heating on the Efficiency of Columns Operated under Very High PressuresAnalytical Chemistry, 2009
- Heat Exchanges in Fast, High-Performance Liquid Chromatography. A Complete Thermodynamic StudyAnalytical Chemistry, 2008
- Unusual behavior of the height equivalent to a theoretical plate of a new poroshell stationary phase at high temperaturesJournal of Chromatography A, 2007
- Comparative study of the performance of columns packed with several new fine silica particles: Would the external roughness of the particles affect column properties?Journal of Chromatography A, 2007
- The art and science of forming packed analytical high-performance liquid chromatography columnsJournal of Chromatography A, 2006
- Mechanics of column beds: II. Modeling of coupled stress‐strain‐flow behaviorAIChE Journal, 2003
- Liquid volume at normal boiling pointThe Canadian Journal of Chemical Engineering, 1996
- Equations for calculation of chromatographic figures of merit for ideal and skewed peaksAnalytical Chemistry, 1983
- Correlation of diffusion coefficients in dilute solutionsAIChE Journal, 1955