Pull-out strength of cemented solidversusfenestrated pedicle screws in osteoporotic vertebrae
Authors:
Open Access
- 1 September 2016
- journal article
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 5 (9) , 419-426
Abstract
Objectives: Cement augmentation of pedicle screws could be used to improve screw stability, especially in osteoporotic vertebrae. However, little is known concerning the influence of different screw types and amount of cement applied. Therefore, the aim of this biomechanical in vitro study was to evaluate the effect of cement augmentation on the screw pull-out force in osteoporotic vertebrae, comparing different pedicle screws (solid and fenestrated) and cement volumes (0 mL, 1 mL or 3 mL).Materials and Methods: A total of 54 osteoporotic human cadaver thoracic and lumbar vertebrae were instrumented with pedicle screws (uncemented, solid cemented or fenestrated cemented) and augmented with high-viscosity PMMA cement (0 mL, 1 mL or 3 mL). The insertion torque and bone mineral density were determined. Radiographs and CT scans were undertaken to evaluate cement distribution and cement leakage. Pull-out testing was performed with a material testing machine to measure failure load and stiffness. The paired t-test was used to compare the two screws within each vertebra.Results: Mean failure load was significantly greater for fenestrated cemented screws (+622 N; p ⩽ 0.001) and solid cemented screws (+460 N; p ⩽ 0.001) than for uncemented screws. There was no significant difference between the solid and fenestrated cemented screws (p = 0.5). In the lower thoracic vertebrae, 1 mL cement was enough to significantly increase failure load, while 3 mL led to further significant improvement in the upper thoracic, lower thoracic and lumbar regions.Conclusion: Conventional, solid pedicle screws augmented with high-viscosity cement provided comparable screw stability in pull-out testing to that of sophisticated and more expensive fenestrated screws. In terms of cement volume, we recommend the use of at least 1 mL in the thoracic and 3 mL in the lumbar spine. Cite this article: C. I. Leichtle, A. Lorenz, S. Rothstock, J. Happel, F. Walter, T. Shiozawa, U. G. Leichtle. Pull-out strength of cemented solid versus fenestrated pedicle screws in osteoporotic vertebrae. Bone Joint Res 2016;5:419–426.Keywords
This publication has 30 references indexed in Scilit:
- Cement embolism into the venous system after pedicle screw fixation: case report, literature review, and prevention tipsOrthopedic Reviews, 2013
- Pedicle Screw Design and Cement Augmentation in Osteoporotic VertebraeSpine, 2012
- Fenestrated pedicle screws for cement-augmented purchase in patients with bone softening: a review of 21 casesJournal of Orthopaedics and Traumatology, 2011
- Instrumented lumbar arthrodesis in elderly patients: prospective study using cannulated cemented pedicle screw instrumentationEuropean Spine Journal, 2011
- Polymethylmethacrylate augmentation of the pedicle screw: the cement distribution in the vertebral bodyEuropean Spine Journal, 2011
- Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-fillingBMC Musculoskeletal Disorders, 2011
- Revision of Cannulated and Perforated Cement-Augmented Pedicle ScrewsSpine, 2010
- Revision characteristics of cement-augmented, cannulatedfenestrated pedicle screws in the osteoporotic vertebral body: a biomechanical in vitro investigationJournal of Neurosurgery: Spine, 2009
- Polymethylmethacrylate-Augmented Screw Fixation for Stabilization of the Osteoporotic Spine : A Three-Year Follow-Up of 37 PatientsJournal of Korean Neurosurgical Society, 2009
- Assessment of different screw augmentation techniques and screw designs in osteoporotic spinesEuropean Spine Journal, 2008