    Pull-out strength of cemented solidversusfenestrated pedicle screws in osteoporotic vertebrae

    by C. I. Leichtle, A. Lorenz, S. Rothstock, J. Happel, F. Walter, T. Shiozawa, U. G. Leichtle

    Objectives: Cement augmentation of pedicle screws could be used to improve screw stability, especially in osteoporotic vertebrae. However, little is known concerning the influence of different screw types and amount of cement applied. Therefore, the aim of this biomechanical in vitro study was to evaluate the effect of cement augmentation on the screw pull-out force in osteoporotic vertebrae, comparing different pedicle screws (solid and fenestrated) and cement volumes (0 mL, 1 mL or 3 mL).Materials and Methods: A total of 54 osteoporotic human cadaver thoracic and lumbar vertebrae were instrumented with pedicle screws (uncemented, solid cemented or fenestrated cemented) and augmented with high-viscosity PMMA cement (0 mL, 1 mL or 3 mL). The insertion torque and bone mineral density were determined. Radiographs and CT scans were undertaken to evaluate cement distribution and cement leakage. Pull-out testing was performed with a material testing machine to measure failure load and stiffness. The paired t-test was used to compare the two screws within each vertebra.Results: Mean failure load was significantly greater for fenestrated cemented screws (+622 N; p ⩽ 0.001) and solid cemented screws (+460 N; p ⩽ 0.001) than for uncemented screws. There was no significant difference between the solid and fenestrated cemented screws (p = 0.5). In the lower thoracic vertebrae, 1 mL cement was enough to significantly increase failure load, while 3 mL led to further significant improvement in the upper thoracic, lower thoracic and lumbar regions.Conclusion: Conventional, solid pedicle screws augmented with high-viscosity cement provided comparable screw stability in pull-out testing to that of sophisticated and more expensive fenestrated screws. In terms of cement volume, we recommend the use of at least 1 mL in the thoracic and 3 mL in the lumbar spine. Cite this article: C. I. Leichtle, A. Lorenz, S. Rothstock, J. Happel, F. Walter, T. Shiozawa, U. G. Leichtle. Pull-out strength of cemented solid versus fenestrated pedicle screws in osteoporotic vertebrae. Bone Joint Res 2016;5:419–426.


  • Tibial rotation influences anterior knee stability — a robot-aided in-vitro study

    by Andrea Lorenz, Heike Röttgerkamp, Evgenij Bobrowitsch, Carmen I. Leichtle, Ulf G. Leichtle


  • Open Access

    Practicability for robot-aided measurement of knee stability in-vivo

    by Andrea Lorenz, Verena Krickl, Ingmar Ipach, Eva-Maria Arlt, Nikolaus Wülker, Ulf G. Leichtle

    For the analysis of different treatments concerning anterior cruciate ligament (ACL) rupture, objective methods for the quantification of knee stability are needed. Therefore, a new method for in-vivo stability measurement using a robotic testing system should be developed and evaluated. A new experimental setting was developed using a KUKA robot and a custom-made chair for the positioning and fixation of the participants. The tibia was connected to the robot via a Vacoped shoe and magnetic buttons, providing adequate safety. Anterior tibial translation and internal tibial rotation were measured on both legs of 40 healthy human subjects at 30°, 60° and 90° of flexion, applying anterior forces of 80 N and internal torques of 4 Nm, respectively. While the mean differences between the right and left leg measured for anterior tibial translation were within an acceptable range (<1.5 mm), the absolute values were substantially large (38–40.5 mm). For mean internal tibial rotation, between 17.5 and 20° were measured at the different sides and flexion angles, with a maximal difference of 0.75°. High reproducibility of the measurements could be demonstrated for both, anterior tibial translation (ICC(3,1) = 0.97) and internal tibial rotation (ICC(3,1) = 0.94). Excellent results were achieved for internal tibial rotation, almost reproducing current in-vitro studies, but too large anterior tibial translation was measured due to soft-tissue compression. Therefore, high potential for the analysis of ACL related treatments concerning rotational stability is seen for the proposed method, but further optimization is necessary to enhance this method for the reliable measurement of anterior tibial translation.


  • Open Access

    Robot-aided in vitro measurement of patellar stability with consideration to the influence of muscle loading

    by Andrea Lorenz, Evgenij Bobrowitsch, Markus Wünschel, Christian Walter, Nikolaus Wülker, Ulf G Leichtle

    Anterior knee pain is often associated with patellar maltracking and instability. However, objective measurement of patellar stability under clinical and experimental conditions is difficult, and muscular activity influences the results. In the present study, a new experimental setting for in vitro measurement of patellar stability was developed and the mediolateral force–displacement behavior of the native knee analyzed with special emphasis on patellar tilt and muscle loading. In the new experimental setup, two established testing methods were combined: an upright knee simulator for positioning and loading of the knee specimens, and an industry robot for mediolateral patellar displacement. A minimally invasive coupling and force control mechanism enabled unconstrained motion of the patella as well as measurement of patellar motion in all six degrees of freedom via an external ultrasonic motion-tracking system. Lateral and medial patellar displacement were measured on seven fresh-frozen human knee specimens in six flexion angles with varying muscle force levels, muscle force distributions, and displacement forces. Substantial repeatability was achieved for patellar shift (ICC(3,1) = 0.67) and tilt (ICC(3,1) = 0.75). Patellar lateral and medial shift decreased slightly with increasing flexion angle. Additional measurement of patellar tilt provided interesting insights into the different displacement mechanisms in lateral and medial directions. For lateral displacement, the patella tilted in the same (lateral) direction, and tilted in the opposite direction (again laterally) for medial displacement. With regard to asymmetric muscle loading, a significant influence (p < 0.03, up to 5 mm shift and 8° tilt) was found for lateral displacement and a reasonable relationship between muscle and patellar force, whereas no effect was visible in the medial direction. The developed experimental setup delivered reproducible results and was found to be an excellent testing method for the in vitro analysis of patellar stability and future investigation of surgical techniques for patellar stabilization and total knee arthroplasty. We demonstrated a significant influence of asymmetric quadriceps loading on patellar stability. In particular, increased force application on the vastus lateralis muscle led to a clear increase of lateral patellar displacement.


  • Changes in dissipated energy and contact pressure after osteochondral graft transplantation

    by Evgenij Bobrowitsch, Andrea Lorenz, Johanna Jörg, Ulf G. Leichtle, Nikolaus Wülker, Christian Walter

    Osteochondral autologous transplantation is frequently used to repair small cartilage defects. Incongruence between the osteochondral graft surface and the adjacent cartilage leads to changed friction and contact pressure. The present study wanted to analyze the differences between intact and surgically treated cartilage surface in respect to contact pressure and frictional characteristic (dissipated energy). Six ovine carpometacarpal joints were used in the present study. Dissipated energy during instrumentally controlled joint movement as well as static contact pressure were measured in different cartilage states (intact, defect, deep-, flush-, high-implanted osteochondral graft and cartilage failure simulation on a high-implanted graft). The best contact area restoration was observed after the flush implantation. However, the dissipated energy measurements did not reveal an advantage of the flush implantation compared to the defect and deep-implanted graft states. The high-implanted graft was associated with a significant increase of the mean contact pressure and decrease of the contact area but the dissipated energy was on the level of intact cartilage in contrast to other treatments where the dissipated energy was significantly higher as in the intact state. However the cartilage failure simulation on the high-implanted graft showed the highest increase of the dissipated energy.


  • Open Access

    Simulation of in vivo dynamics during robot assisted joint movement

    by Evgenij Bobrowitsch, Andrea Lorenz, Nikolaus Wülker, Christian Walter

    Robots are very useful tools in orthopedic research. They can provide force/torque controlled specimen motion with high repeatability and precision. A method to analyze dissipative energy outcome in an entire joint was developed in our group. In a previous study, a sheep knee was flexed while axial load remained constant during the measurement of dissipated energy. We intend to apply this method for the investigation of osteoarthritis. Additionally, the method should be improved by simulation of in vivo knee dynamics. Thus, a new biomechanical testing tool will be developed for analyzing in vitro joint properties after different treatments. Discretization of passive knee flexion was used to construct a complex flexion movement by a robot and simulate altering axial load similar to in vivo sheep knee dynamics described in a previous experimental study. The robot applied an in vivo like axial force profile with high reproducibility during the corresponding knee flexion (total standard deviation of 0.025 body weight (BW)). A total residual error between the in vivo and simulated axial force was 0.16 BW. Posterior-anterior and medio-lateral forces were detected by the robot as a backlash of joint structures. Their curve forms were similar to curve forms of corresponding in vivo measured forces, but in contrast to the axial force, they showed higher total standard deviation of 0.118 and 0.203 BW and higher total residual error of 0.79 and 0.21 BW for posterior-anterior and medio-lateral forces respectively. We developed and evaluated an algorithm for the robotic simulation of complex in vivo joint dynamics using a joint specimen. This should be a new biomechanical testing tool for analyzing joint properties after different treatments.


  • The influence of asymmetric quadriceps loading on patellar tracking — An in vitro study

    by Andrea Lorenz, Otto Müller, Philipp Kohler, Markus Wünschel, Nikolaus Wülker, Ulf G. Leichtle


  • THE INFLUENCE OF THE PATELLOFEMORAL GROOVE DESIGN ON PATELLA KINEMATICS AND PRESSURE IN TKA

    by Andrea Lorenz, Barbara Lange, Yvonne Herzog, Peter Schnauffer, Markus Wünschel, Nikolaus Wülker, Ulf G. Leichtle