Microstructure Degradation of LSM/YSZ Cathodes for Solid Oxide Fuel Cells Aged in Stack after Long Operation Time
- 5 October 2017
- journal article
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 164 (13) , F1385-F1391
Abstract
The performance of solid oxide fuel cells (SOFCs) as well as their lifetime are strongly dependent on electrode microstructure. In this paper the effects of long exposure time (up to 20 000 h) under realistic operation conditions (T = 850°C, J = 190–250 mA·cm−2) in the microstructural degradation are investigated for porous Lanthanum Strontium Manganite (LSM)/Yttria-Stabilized Zirconia (YSZ) cathodes in order to understand the microstructural evolution in SOFC cermet cathodes. Data acquired from high resolution and optimized 3D imaging technique Focused Ion Beam (FIB)/Scanning Electron Microscope (SEM) was used in the quantification of various cathode structures aged during different operating times (2 500 h, 15 000 h and 20 000 h). The methodologies of tomography enable a precise quantification of particle grain growth, connectivity, tortuosity factor and triple phase boundary length (TPBL). Statistically no significant 3D microstructural changes were observed in the cathode by increasing the operating time. The quantitative results from the FIB/SEM tomography were combined with additional semi quantitative measurements done by X-ray fluorescence (XRF) in order to study the chrome poisoning in the cathodes. Both techniques led to a more thorough description of the degradation phenomena in the microstructures of LSM-based cathodes.Keywords
Funding Information
- German Ministery of Education and Research (BMBF) (FKZ: 03SF0494E)
- EWE (EWE AG, Oldenburg)
This publication has 49 references indexed in Scilit:
- Hexis’ SOFC System Galileo 1000 N – Lab and Field Test ExperiencesECS Transactions, 2013
- Durability of Solid Oxide CellsGreen, 2011
- Fuel cell micro-CHP techno-economics: Part 2 – Model application to consider the economic and environmental impact of stack degradationInternational Journal of Hydrogen Energy, 2009
- Fundamental mechanisms limiting solid oxide fuel cell durabilityJournal of Power Sources, 2008
- Assessment of the Cathode Contribution to the Degradation of Anode-Supported Solid Oxide Fuel CellsJournal of the Electrochemical Society, 2008
- Electrical degradation of porous and dense LSM/YSZ interfaceSolid State Ionics, 2006
- Microstructure and cathodic performance of La0.9Sr0.1MnO3/yttria-stabilized zirconia composite electrodesElectrochimica Acta, 2001
- La2Zr2O7 formation and oxygen reduction kinetics of the La0.85Sr0.15MnyO3, O2(g)|YSZ systemSolid State Ionics, 1998
- Electrode Properties of Sr‐Doped LaMnO3 on Yttria‐Stabilized Zirconia: I. Three‐Phase Boundary AreaJournal of the Electrochemical Society, 1997
- Survey of materials selection for ceramic fuel cells II. Cathodes and anodesSolid State Ionics, 1996