Atef Zekri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Atef Zekri has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Martin Knipper
Energy and Semiconductor Research Laboratory, Department of Physics, University of Oldenburg, 26129 Oldenburg, Germany
4 shared publications Jürgen Parisi
Energy and Semiconductor Research Laboratory, Department of Physics, University of Oldenburg, 26129 Oldenburg, Germany
2 shared publicationsThorsten Plaggenborg
Energy and Semiconductor Research Laboratory, Department of Physics, University of Oldenburg, 26129 Oldenburg, Germany
2 shared publications- Abdel-Aziz El Mel
College of Science and Engineering Hamad Bin Khalifa University P.O. Box 34110 Doha Qatar
1 shared publication Akshath Shetty
Qatar Environment and Energy Research Institute Hamad Bin Khalifa University Doha Qatar and
1 shared publication- Bernhard Schnetger
Carl von Ossietzky Universität
1 shared publication
Latest Publications
- Open Access
- 22 October 2020
- Published by Beilstein Institut in Beilstein Journal of Nanotechnology
- Vol. 11 (1) , 1608-1614
Oxidation of Au/Ag films by oxygen plasma: phase separation and generation of nanoporosity
Oxidation of Au/Ag films by oxygen plasma: phase separation and generation of nanoporosity
- 22 October 2020
- Published by Beilstein Institut in Beilstein Journal of Nanotechnology
- Vol. 11 (1) , 1608-1614
Open AccessOxidation of Au/Ag films by oxygen plasma: phase separation and generation of nanoporosity
Oxidation of Au/Ag films by oxygen plasma: phase separation and generation of nanoporosity
- 1 March 2018
- Published by Elsevier in Journal of Power Sources
- Vol. 380, 26-36
Sulfur poisoning of Ni/Gadolinium-doped ceria anodes: A long-term study outlining stable solid oxide fuel cell operation
- 1 March 2018
- Published by Elsevier in Journal of Power Sources
- Vol. 380, 26-36
Sulfur poisoning of Ni/Gadolinium-doped ceria anodes: A long-term study outlining stable solid oxide fuel cell operation
- 5 October 2017
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 164 (13) , F1385-F1391
Microstructure Degradation of LSM/YSZ Cathodes for Solid Oxide Fuel Cells Aged in Stack after Long Operation Time
The performance of solid oxide fuel cells (SOFCs) as well as their lifetime are strongly dependent on electrode microstructure. In this paper the effects of long exposure time (up to 20 000 h) under realistic operation conditions (T = 850°C, J = 190–250 mA·cm−2) in the microstructural degradation are investigated for porous Lanthanum Strontium Manganite (LSM)/Yttria-Stabilized Zirconia (YSZ) cathodes in order to understand the microstructural evolution in SOFC cermet cathodes. Data acquired from high resolution and optimized 3D imaging technique Focused Ion Beam (FIB)/Scanning Electron Microscope (SEM) was used in the quantification of various cathode structures aged during different operating times (2 500 h, 15 000 h and 20 000 h). The methodologies of tomography enable a precise quantification of particle grain growth, connectivity, tortuosity factor and triple phase boundary length (TPBL). Statistically no significant 3D microstructural changes were observed in the cathode by increasing the operating time. The quantitative results from the FIB/SEM tomography were combined with additional semi quantitative measurements done by X-ray fluorescence (XRF) in order to study the chrome poisoning in the cathodes. Both techniques led to a more thorough description of the degradation phenomena in the microstructures of LSM-based cathodes.
- 5 October 2017
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 164 (13) , F1385-F1391
Microstructure Degradation of LSM/YSZ Cathodes for Solid Oxide Fuel Cells Aged in Stack after Long Operation Time
The performance of solid oxide fuel cells (SOFCs) as well as their lifetime are strongly dependent on electrode microstructure. In this paper the effects of long exposure time (up to 20 000 h) under realistic operation conditions (T = 850°C, J = 190–250 mA·cm−2) in the microstructural degradation are investigated for porous Lanthanum Strontium Manganite (LSM)/Yttria-Stabilized Zirconia (YSZ) cathodes in order to understand the microstructural evolution in SOFC cermet cathodes. Data acquired from high resolution and optimized 3D imaging technique Focused Ion Beam (FIB)/Scanning Electron Microscope (SEM) was used in the quantification of various cathode structures aged during different operating times (2 500 h, 15 000 h and 20 000 h). The methodologies of tomography enable a precise quantification of particle grain growth, connectivity, tortuosity factor and triple phase boundary length (TPBL). Statistically no significant 3D microstructural changes were observed in the cathode by increasing the operating time. The quantitative results from the FIB/SEM tomography were combined with additional semi quantitative measurements done by X-ray fluorescence (XRF) in order to study the chrome poisoning in the cathodes. Both techniques led to a more thorough description of the degradation phenomena in the microstructures of LSM-based cathodes.
- 29 May 2017
- Published by Wiley in Fuel Cells
- Vol. 17 (3) , 359-366
Nickel Depletion and Agglomeration in SOFC Anodes During Long‐Term Operation
Low degradation is a key feature for a successful commercialization of solid oxide fuel cell (SOFC) systems. A variety of degradation mechanisms influences the overall degradation rate. Nickel depletion, agglomeration and coarsening in anodes during operation are considered as an important degradation mechanism. In this work, the microstructure of SOFC anodes of electrolyte‐supported cells with operation times up to 20,000 hours (850 °C) were analyzed. The examined anodes consist of a porous cermet of nickel and gadolinium doped ceria. Scanning electron microscopy (SEM) and energy‐dispersive X‐ray (EDX) analysis were used to investigate the nickel distribution in the anode. The results show nickel depletion at the electrolyte/anode interface, which becomes more noticeable for increased operation time. In addition, nickel agglomeration in the contact layer and in the functional layer was found. A relationship between nickel agglomeration and depletion was deduced.
- 29 May 2017
- Published by Wiley in Fuel Cells
- Vol. 17 (3) , 359-366
Nickel Depletion and Agglomeration in SOFC Anodes During Long‐Term Operation
Low degradation is a key feature for a successful commercialization of solid oxide fuel cell (SOFC) systems. A variety of degradation mechanisms influences the overall degradation rate. Nickel depletion, agglomeration and coarsening in anodes during operation are considered as an important degradation mechanism. In this work, the microstructure of SOFC anodes of electrolyte‐supported cells with operation times up to 20,000 hours (850 °C) were analyzed. The examined anodes consist of a porous cermet of nickel and gadolinium doped ceria. Scanning electron microscopy (SEM) and energy‐dispersive X‐ray (EDX) analysis were used to investigate the nickel distribution in the anode. The results show nickel depletion at the electrolyte/anode interface, which becomes more noticeable for increased operation time. In addition, nickel agglomeration in the contact layer and in the functional layer was found. A relationship between nickel agglomeration and depletion was deduced.
- 9 May 2017
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 19 (21) , 13767-13777
Microstructure degradation of Ni/CGO anodes for solid oxide fuel cells after long operation time using 3D reconstructions by FIB tomography
Solid oxide fuel cells (SOFCs) are electrochemical conversion devices, which essentially consist of two porous electrodes separated by a dense, oxide ion conducting electrolyte. The performance and the durability of SOFCs strongly depend on the electrode microstructure. In this paper, the impact of a relatively long exposure time (up to 20 000 h) under realistic operation terms (temperature (T) = 850 °C, current density (J) = 190–250 mA cm−2) in the kinetics of microstructural degradation are investigated for porous nickel (Ni)/ceria gadolinium oxide (CGO) anodes, to understand the microstructural evolution in SOFC cermet anodes. A combined system of Focused Ion Beam (FIB) and Scanning Electron Microscope (SEM) tomography was used to analyze various anode microstructures aged during different operating times (2500 h, 15 000 h and 20 000 h). The methodologies of image acquisition as well as the segmentation and the object recognition were improved, offering a reliable quantification of Ni-grain growth, connectivity, tortuosity factor and triple phase boundary length (TPBL). The representative volume element (RVE) was also studied, and its dependence on aging time was confirmed. To construct a volume that can be accurate and representative for the whole sample, the necessary corresponding 3D reconstruction size was adjusted by increasing operating time, in order to suppress the influence of microstructure variation caused by Ni and CGO agglomeration. Statistically significant 3D microstructural changes were observed in the anode by increasing the operating time, including nickel particle size distribution, changes in connectivity of the ceramic part (CGO) and a significant decrease of contiguous triple phase boundary densities. Additional qualitative observations were done in order to gain a complete insight of the degradation phenomena in nickel based cermet anodes.
- 9 May 2017
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 19 (21) , 13767-13777
Microstructure degradation of Ni/CGO anodes for solid oxide fuel cells after long operation time using 3D reconstructions by FIB tomography
Solid oxide fuel cells (SOFCs) are electrochemical conversion devices, which essentially consist of two porous electrodes separated by a dense, oxide ion conducting electrolyte. The performance and the durability of SOFCs strongly depend on the electrode microstructure. In this paper, the impact of a relatively long exposure time (up to 20 000 h) under realistic operation terms (temperature (T) = 850 °C, current density (J) = 190–250 mA cm−2) in the kinetics of microstructural degradation are investigated for porous nickel (Ni)/ceria gadolinium oxide (CGO) anodes, to understand the microstructural evolution in SOFC cermet anodes. A combined system of Focused Ion Beam (FIB) and Scanning Electron Microscope (SEM) tomography was used to analyze various anode microstructures aged during different operating times (2500 h, 15 000 h and 20 000 h). The methodologies of image acquisition as well as the segmentation and the object recognition were improved, offering a reliable quantification of Ni-grain growth, connectivity, tortuosity factor and triple phase boundary length (TPBL). The representative volume element (RVE) was also studied, and its dependence on aging time was confirmed. To construct a volume that can be accurate and representative for the whole sample, the necessary corresponding 3D reconstruction size was adjusted by increasing operating time, in order to suppress the influence of microstructure variation caused by Ni and CGO agglomeration. Statistically significant 3D microstructural changes were observed in the anode by increasing the operating time, including nickel particle size distribution, changes in connectivity of the ceramic part (CGO) and a significant decrease of contiguous triple phase boundary densities. Additional qualitative observations were done in order to gain a complete insight of the degradation phenomena in nickel based cermet anodes.