Comparison of depth of electrode insertion between cochleostomy and round window approach: a cadaveric study
Authors:
- Anupriya JangraAJAnupriya Jangra
- K. Nidhin DasKDK. Nidhin Das
- Vidhu SharmaVSVidhu Sharma
- Sailaja TimmarajuSTSailaja Timmaraju
- Pushpinder KheraPKPushpinder Khera
- Sarbesh TiwariSTSarbesh Tiwari
- Kapil SoniKSKapil Soni
- Bikram ChoudhuryBCBikram Choudhury
- Surajit GhatakSGSurajit Ghatak
- Shilpi Gupta DixitSDShilpi Gupta Dixit
- Ashish Kumar NayyarANAshish Kumar Nayyar
- Amit GoyalAGAmit Goyal
- 31 January 2024
- journal article
- research article
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 281 (7) , 3547-3555
Abstract
Introduction Round window approach and cochleostomy approach can have different depth of electrode insertion during cochlear implantation which itself can alter the audiological outcomes in cochlear implant. Objective The current study was conducted to determine the difference in the depth of electrode insertion via cochleostomy and round widow approach when done serially in same temporal bone. Methodology This is a cross-sectional study conducted in the Department of Otorhinolaryngology in conjunction with Department of Anatomy and Department of Diagnostic and Interventional Radiology over a period of 1 year. 12-electrode array insertion was performed via either approach (cochleostomy or round window) in the cadaveric temporal bone. HRCT temporal bone scan of the implanted temporal bone was done and depth of insertion and various cochlear parameters were calculated. Result A total of 12 temporal bones were included for imaging analysis. The mean cochlear duct length was 32.892 mm; the alpha and beta angles were 58.175° and 8.350°, respectively. The mean angular depth of electrode insertion via round window was found to be 325.2° (SD = 150.5842) and via cochleostomy 327.350 (SD = 112.79) degree and the mean linear depth of electrode insertion via round window was found to be 18.80 (SD = 4.4962) mm via cochleostomy 19.650 (SD = 3.8087) mm, which was calculated using OTOPLAN 1.5.0 software. There was a statically significant difference in linear depth of insertion between round window and cochleostomy. Although the angular depth of insertion was higher in CS group, there was no statistically significant difference with round window type of insertion. Conclusion The depth of electrode insertion is one of the parameters that influences the hearing outcome. Linear depth of electrode insertion was found to be more in case of cochleostomy compared to round window approach (p = 0.075) and difference in case of angular depth of electrode insertion existed but not significant (p = 0.529).Keywords
This publication has 20 references indexed in Scilit:
- Insertion depth impacts speech perception and hearing preservation for lateral wall electrodesThe Laryngoscope, 2017
- The Effect of Round Window vs Cochleostomy Surgical Approaches on Cochlear Implant Electrode PositionJAMA Otolaryngology–Head & Neck Surgery, 2016
- Optimal electrode length to match patient specific cochlear anatomyEuropean Annals of Otorhinolaryngology, Head and Neck Diseases, 2016
- Measurement of Cochlear Implant Electrode Position From Intraoperative Post-insertion Skull RadiographsOtology & Neurotology, 2015
- Method to Estimate the Complete and Two-Turn Cochlear Duct LengthOtology & Neurotology, 2015
- Correlation of Cochlear Nerve Size and Auditory Performance After Cochlear Implantation in Postlingually Deaf PatientsCochlear Nerve Size and Auditory PerformanceJAMA Otolaryngology–Head & Neck Surgery, 2013
- Is Word Recognition Correlated With the Number of Surviving Spiral Ganglion Cells and Electrode Insertion Depth in Human Subjects With Cochlear Implants?The Laryngoscope, 2005
- Development and Evaluation of an Improved Cochlear Implant Electrode Design for Electric Acoustic StimulationThe Laryngoscope, 2004
- Preoperative Temporal Bone Computed Tomography Scan and Its Use in Evaluating the Pediatric Cochlear Implant CandidateThe Laryngoscope, 1997
- Temporal bone imaging for cochlear implantationThe Laryngoscope, 1994