Gafchromic EBT3 film provides equivalent dosimetric performance to EBT-XD film for stereotactic radiosurgery dosimetry
Open Access
- 13 May 2024
- journal article
- research article
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 47 (3) , 1095-1106
Abstract
The accurate assessment of film results is highly dependent on the methodology and techniques used to process film. This study aims to compare the performance of EBT3 and EBT-XD film for SRS dosimetry using two different film processing methods. Experiments were performed in a solid water slab and an anthropomorphic head phantom. For each experiment, the net optical density of the film was calculated using two different methods; taking the background (initial) optical density from 1) an unirradiated film from the same film lot as the irradiated film (stock to stock (S-S) method), and 2) a scan of the same piece of film taken prior to irradiation (film to film (F-F) method). EBT3 and EBT-XD performed similarly across the suite of experiments when using the green channel only or with triple channel RGB dosimetry. The dosimetric performance of EBT-XD was improved across all colour channels by using an F-F method, particularly for the blue channel. In contrast, EBT3 performed similarly well regardless of the net optical density method used. Across 21 SRS treatment plans, the average per-pixel agreement between EBT3 and EBT-XD films, normalised to the 20 Gy prescription dose, was within 2% and 4% for the non-target (2—10 Gy) and target (> 10 Gy) regions, respectively, when using the F-F method. At doses relevant to SRS, EBT3 provides comparable dosimetric performance to EBT-XD. In addition, an S-S dosimetry method is suitable for EBT3 while an F-F method should be adopted if using EBT-XD.Keywords
All Related Versions
This publication has 11 references indexed in Scilit:
- Current status of intra-cranial stereotactic radiotherapy and stereotactic radiosurgery in Australia and New Zealand: key considerations from a workshop and surveysPhysical and Engineering Sciences in Medicine, 2022
- Characterisation of a synthetic diamond detector for end-to-end dosimetry in stereotactic body radiotherapy and radiosurgeryPhysics and Imaging in Radiation Oncology, 2021
- A protocol for absolute dose verification of SBRT/SRS treatment plans using Gafchromic™ EBT-XD filmsPhysica Medica, 2021
- Report of AAPM Task Group 235 Radiochromic Film Dosimetry: An Update to TG‐55Medical Physics, 2020
- Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beamsPhysics in Medicine & Biology, 2018
- Gafchromic EBT‐XD film: Dosimetry characterization in high‐dose, volumetric‐modulated arc therapyJournal of Applied Clinical Medical Physics, 2016
- Evaluation of the uncertainty in an EBT3 film dosimetry system utilizing net optical densityJournal of Applied Clinical Medical Physics, 2016
- Evaluation of Gafchromic EBT-XD film, with comparison to EBT3 film, and application in high dose radiotherapy verificationPhysics in Medicine & Biology, 2015
- Technical Note: Initial characterization of the new EBT‐XD Gafchromic filmMedical Physics, 2015
- Evaluation and mitigation of potential errors in radiochromic film dosimetry due to film curvature at scanningJournal of Applied Clinical Medical Physics, 2015