Abstract
An active shimming magnet was developed to compensate sextupole error fields in a block-type REBCO dipole magnet. The magnet employs a sextupole configuration with three no-insulation double-pancake coils wound from 2 mm-wide REBCO tapes. Standalone tests at 77 K confirmed intact electromagnetic performance after winding and assembly. Field quality measurements at 4.2 K under dipole fields of 1.0 T and 3.1 T showed a linear decrease of sextupole component $b_{3}$ with increasing shimming current up to 30 A, with consistent compensation ability at both fields. The active shimming magnet caused an increase in $b_{5}$ and a decrease in $b_{7}$, both with magnitudes much smaller than that of $b_{3}$, indicating limited impact on overall field quality. These results demonstrate that the active shimming magnet effectively reduces sextupole field errors to within 1 unit, providing a compensation approach for improving field quality in future HTS accelerator dipole magnets.
Funding Information
  • National Natural Science Foundation of China (52277026)
  • National Natural Science Foundation of China (12327901)
  • Strategic Priority Research Program of Chinese Academy of Sciences (XDB25000000)

This publication has 24 references indexed in Scilit: