Abstract
This research proposes an algorithm to preprocess photoplethysmography (PPG) and electrocardiogram (ECG) signals and apply the processed signals to the context aggregation network-based deep learning to achieve higher accuracy of continuous systolic and diastolic blood pressure monitoring than other reported algorithms. The preprocessing method consists of the following steps: (1) acquiring the PPG and ECG signals for a two second window at a sampling rate of 125 Hz; (2) separating the signals into an array of 250 data points corresponding to a 2 s data window; (3) randomizing the amplitude of the PPG and ECG signals by multiplying the 2 s frames by a random amplitude constant to ensure that the neural network can only learn from the frequency information accommodating the signal fluctuation due to instrument attachment and installation; (4) Fourier transforming the windowed PPG and ECG signals obtaining both amplitude and phase data; (5) normalizing both the amplitude and the phase of PPG and ECG signals using z-score normalization; and (6) training the neural network using four input channels (the amplitude and the phase of PPG and the amplitude and the phase of ECG), and arterial blood pressure signal in time-domain as the label for supervised learning. As a result, the network can achieve a high continuous blood pressure monitoring accuracy, with the systolic blood pressure root mean square error of 7 mmHg and the diastolic root mean square error of 6 mmHg. These values are within the error range reported in the literature. Note that other methods rely only on mathematical models for the systolic and diastolic values, whereas the proposed method can predict the continuous signal without degrading the measurement performance and relying on a mathematical model.Keywords
This publication has 40 references indexed in Scilit:
- Which is More Accurate in Measuring the Blood Pressure? A Digital or an Aneroid SphygmomanometerJournal of Clinical and Diagnostic Research, 2016
- Continuous Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity RatioIEEE Transactions on Biomedical Engineering, 2015
- A chair for cuffless real-time estimation of systolic blood pressure based on pulse transit time2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2015
- Relation of blood pressure and body mass index during childhood to cardiovascular risk factor levels in young adultsJournal Of Hypertension, 2009
- An Evaluation of the Cuffless Blood Pressure Estimation Based on Pulse Transit Time Technique: a Half Year Study on Normotensive SubjectsCardiovascular Engineering, 2009
- Separability of ternary codes for sparse designs of error-correcting output codesPattern Recognition Letters, 2009
- Accuracy of blood pressure measurement: sphygmomanometer calibration and beyondJournal Of Hypertension, 2006
- Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood PressureHypertension, 2003
- Human blood pressure determination by sphygmomanometry.Circulation, 1993
- Is high and fluctuating muscle nerve sympathetic activity in the sleep apnoea syndrome of pathogenetic importance for the development of hypertension?Journal Of Hypertension, 1988