Sources of uncertainty in eddy covariance ozone flux measurements made by dry chemiluminescence fast response analysers
Open Access
- 8 February 2010
- journal article
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 3 (1) , 163-176
Abstract
We present a systematic intercomparison study of eddy covariance ozone flux measurements made using two fast response dry chemiluminescence analysers. Ozone deposition was measured over a well characterised managed grassland near Edinburgh, Scotland, during August 2007. A data quality control procedure specific to these analysers is introduced. Absolute ozone fluxes were calculated based on the relative signals of the dry chemiluminescence analysers using three different methods and the results are compared for both analysers. It is shown that the error in the fitted analyser calibration parameters required for the flux calculations provides a substantial source of uncertainty in the fluxes. The choice of the calculation method itself can also constitute an uncertainty in the flux as the calculated fluxes by the three methods do not agree within error at all times. This finding highlights the need for a consistent and rigorous approach for comparable datasets, such as e.g. in flux networks. Ozone fluxes calculated by one of the methods were then used to compare the two analysers in more detail. This systematic analyser comparison reveals half-hourly flux values differing by up to a factor of two at times with the difference in mean hourly flux ranging from 0 to 23% with an error in the mean daily flux of ± 12%. The comparison of analysers shows that the agreement in fluxes is excellent for some days but that there is an underlying uncertainty as a result of variable analyser performance and/or non-linear sensitivity.Keywords
All Related Versions
This publication has 29 references indexed in Scilit:
- Measuring eddy covariance fluxes of ozone with a slow-response analyserAtmospheric Environment, 2009
- Seasonal variation of ozone deposition to a tropical rain forest in southwest AmazoniaAtmospheric Chemistry and Physics, 2007
- Weather newsWeather, 2007
- Modeling seasonal ozone fluxes to grassland and wheat: model improvement, testing, and applicationAtmospheric Environment, 2004
- Ozone deposition to a ponderosa pine plantation in the Sierra Nevada Mountains (CA): A comparison of two different climatic yearsJournal of Geophysical Research: Atmospheres, 2000
- Resistances to ozone deposition to a flark fen in the northern aapa mire zoneJournal of Geophysical Research: Atmospheres, 1998
- On-line measurements of ozone surface fluxes: Part I. Methodology and instrumentationAtmospheric Environment, 1996
- Tools for quality assessment of surface-based flux measurementsAgricultural and Forest Meteorology, 1996
- Measuring ambient ozone with high sensitivity and bandwidthReview of Scientific Instruments, 1990
- Chemiluminescent measurement of atmospheric ozone. Response characteristics and operating variablesAnalytical Chemistry, 1970