Development of a sequential injection–square wave voltammetry method for determination of paraquat in water samples employing the hanging mercury drop electrode
Authors:
- Luciana B O Dos SantosLSLuciana B O Dos Santos
- Carlos M C InfanteCICarlos M C Infante
- Jorge C MasiniJorge C Masini
- 19 January 2010
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 396 (5) , 1897-1903
Abstract
This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h−1. Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 µL s−1. For a concentration range between 0.010 and 0.25 mg L−1, the current (i p, µA) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L−1): i p = (−20.5 ± 0.3)C paraquat − (0.02 ± 0.03). The limits of detection and quantification were 2.0 and 7.0 µg L−1, respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level. Sequential injection manifold to perform sequential injection square wave voltammetryKeywords
This publication has 26 references indexed in Scilit:
- Square wave voltammetry for analytical determination of paraquat at carbon paste electrode modified with fluoroapatiteFood Chemistry, 2008
- A multicommuted flow system with solenoid micro-pumps for paraquat determination in natural watersTalanta, 2008
- Square wave adsorptive cathodic stripping voltammetry automated by sequential injection analysis: Potentialities and limitations exemplified by the determination of methyl parathion in water samplesAnalytica Chimica Acta, 2008
- Determination of picloram in natural waters employing sequential injection square wave voltammetry using the hanging mercury drop electrodeTalanta, 2007
- Development of a Spectrophotometric Sequential Injection Methodology for Online Monitoring of the Adsorption of Paraquat on Clay Mineral and SoilSpectroscopy Letters, 2007
- Electrochemical detection of the herbicide paraquat in natural water and citric fruit juices using microelectrodesAnalytica Chimica Acta, 2005
- Developing a sequential injection-square wave voltammetry (SI-SWV) method for determination of atrazine using a hanging mercury drop electrodeAnalytica Chimica Acta, 2005
- Experimental design employed to square wave voltammetry response optimization for the glyphosate determinationJournal of the Brazilian Chemical Society, 2004
- Determination of atrazine using square wave voltammetry with the Hanging Mercury Drop Electrode (HMDE)Talanta, 2004
- Determination of paraquat by flow-injection spectrophotometryAnalytica Chimica Acta, 1987