Population exposure to ionising radiation from CT examinations in Aosta Valley between 2001 and 2008
Authors:
- 1 December 2010
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 83 (996) , 1042-1051
Abstract
Recent and continuous advances in CT, such as the development of multislice CT, have promoted a rapid increase in its clinical application. Today, CT accounts for approximately 10% of the total number of medical radiographic procedures worldwide. However, the growing performance of the new CT generations have increased not only the diagnostic opportunities, but also the radiation dose to the patient. The relative contribution to the collective radiation dose is now estimated to be approximately 50%. Several papers have been published concerning the intensive use of CT and its contribution to the collective dose. However, most of the literature concerns the years 1997-2003 and the dosimetric evaluations are generally limited to the main standard protocols (chest, head and abdomen), deriving the effective dose by the simple application of the diagnostic reference levels. Only specific dosimetric analyses of single and innovative procedures have been published recently. Moreover, few data comes from Italian radiology departments. This paper aims to bridge these gaps. Firstly, it characterises in terms of measured CT dose index (CTDI) two last-generation scanners of the Radiological Department of Aosta Hospital. Secondly, it evaluates the effective dose from most of the CT examinations performed from 2001 to 2008 to compare protocols and technologies in line with the suggestions of the 2007 Recommendations of the International Commission on Radiological Protection, Publication 103. Finally, it estimates the collective dose to the population.Keywords
This publication has 16 references indexed in Scilit:
- The revision of RP 91 on criteria for acceptability of radiological (including radiotherapy) andnuclear medicine installationsRadiation Protection Dosimetry, 2012
- Analysis of Current Practice of CT examinationsActa Oncologica, 2009
- Population exposure to ionizing radiation from medical examinations in FranceBritish Journal of Radiology, 2008
- EXPOSURE OF THE SWISS POPULATION BY RADIODIAGNOSTICS: 2003 REVIEWHealth Physics, 2007
- National survey of doses from CT in the UK: 2003British Journal of Radiology, 2006
- MEDICAL EXPOSURE OF THE POPULATION FROM DIAGNOSTIC USE OF IONIZING RADIATION IN LUXEMBOURG BETWEEN 1994 AND 2002Health Physics, 2006
- Radiation Dose Estimates From Cardiac Multislice Computed Tomography in Daily PracticeCirculation, 2006
- Patient exposure in medical X-ray imaging in EuropeRadiation Protection Dosimetry, 2005
- CT dosimetry: getting the best from the adult Cristy phantomRadiation Protection Dosimetry, 2005
- Effective doses to adult and pediatric patientsPediatric Radiology, 2002