- Vol. 106, S314
PO-0821: Tomodirect for breast cancer patients with supraclavicular nodes involvement
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S314
Open AccessPO-0821: Tomodirect for breast cancer patients with supraclavicular nodes involvement
- Open Access
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S433
EP-1148: In vivo dosimetry with mosfet detectors for whole breast tomodirect treatments
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S433
Open AccessEP-1148: In vivo dosimetry with mosfet detectors for whole breast tomodirect treatments
- Open Access
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S231-S232
PD-0600: A geometrical analysis focused on the beam-on time reduction in helical tomotherapy-based SBRT for lung tumors.
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S231-S232
Open AccessPD-0600: A geometrical analysis focused on the beam-on time reduction in helical tomotherapy-based SBRT for lung tumors.
- Open Access
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S397
EP-1039: Hypofractionated breast radiation and simultaneous integrated boost with TomoDirect: a prospective phase II trial
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S397
Open AccessEP-1039: Hypofractionated breast radiation and simultaneous integrated boost with TomoDirect: a prospective phase II trial
- Open Access
- 14 December 2012
- Published by Springer Nature in Radiation Oncology
- Vol. 7 (1) , 211
Does TomoDirect 3DCRT represent a suitable option for post-operative whole breast irradiation? A hypothesis-generating pilot study
Background: This study investigates the use of TomoDirectTM 3DCRT for whole breast adjuvant radiotherapy (AWBRT) that represents a very attractive treatment opportunity, mainly for radiotherapy departments without conventional Linacs and only equipped with helical tomotherapy units. Methods: Plans were created for 17 breast cancer patients using TomoDirect in 3DCRT and IMRT modality and field-in-field 3DCRT planning (FIF) and compared in terms of PTV coverage, overdosage, homogeneity, conformality and dose to OARs. The possibility to define patient-class solutions for TD-3DCRT employment was investigated, correlating OARs dose constraints to patient specific anatomic parameters. Results: TD-3DCRT showed PTV coverage and homogeneity significantly higher than TD-IMRT and FIF. PTV conformality was significantly better for FIF, while no differences were found between TD-3DCRT and TD-IMRT. TD-3DCRT showed mean values of the OARs dosimetric endpoints significantly higher than TD-IMRT; with respect to FIF, TD-3DCRT showed values significantly higher for lung V20Gy, mean heart dose and V25Gy, while contralateral lung maximum dose and contralateral breast mean dose resulted significantly lower. The Central Lung Distance (CLD) and the maximal Heart Distance (HD) resulted as useful clinical tools to predict the opportunity to employ TD-3DCRT: positive correlations were found between CLD and both V20Gy and mean lung dose and between HD and both V25Gy and the mean heart dose. TD-3DCRT showed a significantly shorter mean beam-on time than TD-IMRT. Conclusions: The present study showed that TD-3DCRT and TD-IMRT are two feasible and dosimetrically acceptable treatment approach for AWBRT, with an optimal PTV coverage and adequate OARs sparing. Some concerns might be raised in terms of dose to organs at risks if TD-3DCRT is applied to a general population. A correct patients clusterization according to simple quantitative anatomic measures, would help to correctly allocate patients to the appropriate treatment planning strategy in terms of target coverage, but also of normal tissue sparing.
- 14 December 2012
- Published by Springer Nature in Radiation Oncology
- Vol. 7 (1) , 211
Open AccessDoes TomoDirect 3DCRT represent a suitable option for post-operative whole breast irradiation? A hypothesis-generating pilot study
Background: This study investigates the use of TomoDirectTM 3DCRT for whole breast adjuvant radiotherapy (AWBRT) that represents a very attractive treatment opportunity, mainly for radiotherapy departments without conventional Linacs and only equipped with helical tomotherapy units. Methods: Plans were created for 17 breast cancer patients using TomoDirect in 3DCRT and IMRT modality and field-in-field 3DCRT planning (FIF) and compared in terms of PTV coverage, overdosage, homogeneity, conformality and dose to OARs. The possibility to define patient-class solutions for TD-3DCRT employment was investigated, correlating OARs dose constraints to patient specific anatomic parameters. Results: TD-3DCRT showed PTV coverage and homogeneity significantly higher than TD-IMRT and FIF. PTV conformality was significantly better for FIF, while no differences were found between TD-3DCRT and TD-IMRT. TD-3DCRT showed mean values of the OARs dosimetric endpoints significantly higher than TD-IMRT; with respect to FIF, TD-3DCRT showed values significantly higher for lung V20Gy, mean heart dose and V25Gy, while contralateral lung maximum dose and contralateral breast mean dose resulted significantly lower. The Central Lung Distance (CLD) and the maximal Heart Distance (HD) resulted as useful clinical tools to predict the opportunity to employ TD-3DCRT: positive correlations were found between CLD and both V20Gy and mean lung dose and between HD and both V25Gy and the mean heart dose. TD-3DCRT showed a significantly shorter mean beam-on time than TD-IMRT. Conclusions: The present study showed that TD-3DCRT and TD-IMRT are two feasible and dosimetrically acceptable treatment approach for AWBRT, with an optimal PTV coverage and adequate OARs sparing. Some concerns might be raised in terms of dose to organs at risks if TD-3DCRT is applied to a general population. A correct patients clusterization according to simple quantitative anatomic measures, would help to correctly allocate patients to the appropriate treatment planning strategy in terms of target coverage, but also of normal tissue sparing.
- Open Access
- 2 November 2012
- Published by Springer Nature in Radiation Oncology
- Vol. 7 (1) , 186
Different IMRT solutions vs. 3D-Conformal Radiotherapy in early stage Hodgkin’s lymphoma: dosimetric comparison and clinical considerations
Radiotherapy in Hodgkin’s Lymphoma (HL) is currently evolving with new attempts to further reduce radiation volumes to the involved-node concept (Involved Nodes Radiation Therapy, INRT) and with the use of intensity modulated radiotherapy (IMRT). Currently, IMRT can be planned and delivered with several techniques, and its role is not completely clear. We designed a planning study on a typical dataset drawn from clinical routine with the aim of comparing different IMRT solutions in terms of plan quality and treatment delivery efficiency. A total of 10 young female patients affected with early stage mediastinal HL and treated with 30 Gy INRT after ABVD-based chemotherapy were selected from our database. Five different treatment techniques were compared: 3D-CRT, VMAT (single arc), B-VMAT (“butterfly”, multiple arcs), Helical Tomotherapy (HT) and Tomodirect (TD). Beam energy was 6 MV, and all IMRT planning solutions were optimized by inverse planning with specific dose-volume constraints on OAR (breasts, lungs, thyroid gland, coronary ostia, heart). Dose-Volume Histograms (DVHs) and Conformity Number (CN) were calculated and then compared, both for target and OAR by a statistical analysis (Wilcoxon’s Test). PTV coverage was reached for all plans (V95% ≥ 95%); highest mean CN were obtained with HT (0.77) and VMAT (0.76). B-VMAT showed intermediate CN mean values (0.67), while the lowest CN were obtained with TD (0.30) and 3D-CRT techniques (0.30). A trend of inverse correlation between higher CN and larger healthy tissues volumes receiving low radiation doses was shown for lungs and breasts. For thyroid gland and heart/coronary ostia, HT, VMAT and B-VMAT techniques allowed a better sparing in terms of both Dmean and volumes receiving intermediate-high doses compared to 3D-CRT and TD. IMRT techniques showed superior target coverage and OAR sparing, with, as an expected consequence, larger volumes of healthy tissues (lungs, breasts) receiving low doses. Among the different IMRT techniques, HT and VMAT showed higher levels of conformation; B-VMAT and HT emerged as the planning solutions able to achieve the most balanced compromise between higher conformation around the target and smaller volumes of OAR exposed to lower doses (typical of 3D-CRT).
- 2 November 2012
- Published by Springer Nature in Radiation Oncology
- Vol. 7 (1) , 186
Open AccessDifferent IMRT solutions vs. 3D-Conformal Radiotherapy in early stage Hodgkin’s lymphoma: dosimetric comparison and clinical considerations
Radiotherapy in Hodgkin’s Lymphoma (HL) is currently evolving with new attempts to further reduce radiation volumes to the involved-node concept (Involved Nodes Radiation Therapy, INRT) and with the use of intensity modulated radiotherapy (IMRT). Currently, IMRT can be planned and delivered with several techniques, and its role is not completely clear. We designed a planning study on a typical dataset drawn from clinical routine with the aim of comparing different IMRT solutions in terms of plan quality and treatment delivery efficiency. A total of 10 young female patients affected with early stage mediastinal HL and treated with 30 Gy INRT after ABVD-based chemotherapy were selected from our database. Five different treatment techniques were compared: 3D-CRT, VMAT (single arc), B-VMAT (“butterfly”, multiple arcs), Helical Tomotherapy (HT) and Tomodirect (TD). Beam energy was 6 MV, and all IMRT planning solutions were optimized by inverse planning with specific dose-volume constraints on OAR (breasts, lungs, thyroid gland, coronary ostia, heart). Dose-Volume Histograms (DVHs) and Conformity Number (CN) were calculated and then compared, both for target and OAR by a statistical analysis (Wilcoxon’s Test). PTV coverage was reached for all plans (V95% ≥ 95%); highest mean CN were obtained with HT (0.77) and VMAT (0.76). B-VMAT showed intermediate CN mean values (0.67), while the lowest CN were obtained with TD (0.30) and 3D-CRT techniques (0.30). A trend of inverse correlation between higher CN and larger healthy tissues volumes receiving low radiation doses was shown for lungs and breasts. For thyroid gland and heart/coronary ostia, HT, VMAT and B-VMAT techniques allowed a better sparing in terms of both Dmean and volumes receiving intermediate-high doses compared to 3D-CRT and TD. IMRT techniques showed superior target coverage and OAR sparing, with, as an expected consequence, larger volumes of healthy tissues (lungs, breasts) receiving low doses. Among the different IMRT techniques, HT and VMAT showed higher levels of conformation; B-VMAT and HT emerged as the planning solutions able to achieve the most balanced compromise between higher conformation around the target and smaller volumes of OAR exposed to lower doses (typical of 3D-CRT).
- 1 May 2012
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 103, S387
EP-0980 ADJUVANT BREAST RADIATION DELIVERED WITH STATIC ANGLES TOMOTHERAPY (TOMODIRECT): A PROSPECTIVE EVALUATION
- 1 May 2012
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 103, S387
EP-0980 ADJUVANT BREAST RADIATION DELIVERED WITH STATIC ANGLES TOMOTHERAPY (TOMODIRECT): A PROSPECTIVE EVALUATION
- Open Access
- 15 February 2012
- Published by Springer Nature in Radiation Oncology
- Vol. 7 (1) , 21
Head and neck region consolidation radiotherapy and prophylactic cranial irradiation with hippocampal avoidance delivered with helical tomotherapy after induction chemotherapy for non-sinonasal neuroendocrine carcinoma of the upper airways
Non-sinonasal neuroendocrine carcinomas (NSNECs) of the head and neck are considered an unfrequent clinico-pathological entity. Combined modality treatment represents an established therapeutic option for undifferentiated forms where distant metastasis is a common pattern of failure. We report on a case of NSNEC treated with sequential chemo-radiation consisting of 6 cycles of cisplatin and etoposide followed by loco-regional radiation to the head and neck and simultaneous prophylactic cranial irradiation to prevent from intracranial spread, delivered with helical tomotherapy with the 'hippocampal avoidance' technique in order to reduce neuro-cognitive late effects. One year after the end of the whole combined modality approach, the patient achieved complete remission, with no treatment-related sub-acute and late effects. The present report highlights the importance of multidisciplinary management for NSNECs of the head and neck, as the possibility to achieve substantial cure rates with mild side effects with modern radiotherapy techniques.
- 15 February 2012
- Published by Springer Nature in Radiation Oncology
- Vol. 7 (1) , 21
Open AccessHead and neck region consolidation radiotherapy and prophylactic cranial irradiation with hippocampal avoidance delivered with helical tomotherapy after induction chemotherapy for non-sinonasal neuroendocrine carcinoma of the upper airways
Non-sinonasal neuroendocrine carcinomas (NSNECs) of the head and neck are considered an unfrequent clinico-pathological entity. Combined modality treatment represents an established therapeutic option for undifferentiated forms where distant metastasis is a common pattern of failure. We report on a case of NSNEC treated with sequential chemo-radiation consisting of 6 cycles of cisplatin and etoposide followed by loco-regional radiation to the head and neck and simultaneous prophylactic cranial irradiation to prevent from intracranial spread, delivered with helical tomotherapy with the 'hippocampal avoidance' technique in order to reduce neuro-cognitive late effects. One year after the end of the whole combined modality approach, the patient achieved complete remission, with no treatment-related sub-acute and late effects. The present report highlights the importance of multidisciplinary management for NSNECs of the head and neck, as the possibility to achieve substantial cure rates with mild side effects with modern radiotherapy techniques.
- 1 December 2010
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 83 (996) , 1042-1051
Population exposure to ionising radiation from CT examinations in Aosta Valley between 2001 and 2008
Recent and continuous advances in CT, such as the development of multislice CT, have promoted a rapid increase in its clinical application. Today, CT accounts for approximately 10% of the total number of medical radiographic procedures worldwide. However, the growing performance of the new CT generations have increased not only the diagnostic opportunities, but also the radiation dose to the patient. The relative contribution to the collective radiation dose is now estimated to be approximately 50%. Several papers have been published concerning the intensive use of CT and its contribution to the collective dose. However, most of the literature concerns the years 1997-2003 and the dosimetric evaluations are generally limited to the main standard protocols (chest, head and abdomen), deriving the effective dose by the simple application of the diagnostic reference levels. Only specific dosimetric analyses of single and innovative procedures have been published recently. Moreover, few data comes from Italian radiology departments. This paper aims to bridge these gaps. Firstly, it characterises in terms of measured CT dose index (CTDI) two last-generation scanners of the Radiological Department of Aosta Hospital. Secondly, it evaluates the effective dose from most of the CT examinations performed from 2001 to 2008 to compare protocols and technologies in line with the suggestions of the 2007 Recommendations of the International Commission on Radiological Protection, Publication 103. Finally, it estimates the collective dose to the population.
- 1 December 2010
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 83 (996) , 1042-1051
Population exposure to ionising radiation from CT examinations in Aosta Valley between 2001 and 2008
Recent and continuous advances in CT, such as the development of multislice CT, have promoted a rapid increase in its clinical application. Today, CT accounts for approximately 10% of the total number of medical radiographic procedures worldwide. However, the growing performance of the new CT generations have increased not only the diagnostic opportunities, but also the radiation dose to the patient. The relative contribution to the collective radiation dose is now estimated to be approximately 50%. Several papers have been published concerning the intensive use of CT and its contribution to the collective dose. However, most of the literature concerns the years 1997-2003 and the dosimetric evaluations are generally limited to the main standard protocols (chest, head and abdomen), deriving the effective dose by the simple application of the diagnostic reference levels. Only specific dosimetric analyses of single and innovative procedures have been published recently. Moreover, few data comes from Italian radiology departments. This paper aims to bridge these gaps. Firstly, it characterises in terms of measured CT dose index (CTDI) two last-generation scanners of the Radiological Department of Aosta Hospital. Secondly, it evaluates the effective dose from most of the CT examinations performed from 2001 to 2008 to compare protocols and technologies in line with the suggestions of the 2007 Recommendations of the International Commission on Radiological Protection, Publication 103. Finally, it estimates the collective dose to the population.