Discriminative detection of glucose and urea with a composite polymer nanofiber based matrix
- 2 January 2024
- journal article
- research article
- Published by Wiley in ChemistrySelect
- Vol. 9 (1)
Abstract
Detection and quantification of glucose and urea are fundamental in medical analysis, real‐time monitoring, and point of care analysis. However, such analyses generally require sophisticated instrumentation and specialized personnel. Furthermore, discriminative detection of multiple analytes is often necessary for treatment and diagnosis. To address this challenge, this study describes a proof‐of‐concept for discriminative sensitive amperometric detection of both analytes. This was achieved by the fabrication of a polymer‐MWCNTs composite nanofiber matrix upon which glucose oxidase (GOD) and urease were co‐immobilized to allow detection of the corresponding substrates (glucose and urea). The (PAN(−MWCNTs)/Urease‐GOD) biosensor showed good performance in: (i) glucose biosensing with sensitivity of 31±5 μAmM −2 cm −2 within an extended linear range (0.1–5.0 mM) and a limit of detection of 3.7 μM, and (ii) urea detection at very low concentration (4–30 and 30–90 μM) with sensitivity up to 350±19 μAmM −2 cm −2 and very low LOD (0.1 μM). The analogous mono‐enzyme platform for urea detection (PAN(−MWCNTs)/Urease) showed very similar performance as the bi‐enzyme sensor, suggesting little to no influence of co‐immobilization on Urease activity, thus confirming that the two catalytic processes are independent of each other. The biosensors exhibited high accuracy in the detection of both analytes (at normal and pathological levels) in human serum, thus proving that the biosensor described herein can have practical applications in healthcare and remote patient monitoring.Keywords
This publication has 83 references indexed in Scilit:
- A novel platform for enhanced biosensing based on the synergy effects of electrospun polymer nanofibers and graphene oxidesThe Analyst, 2012
- The effects of carbon nanotube addition and oxyfluorination on the glucose-sensing capabilities of glucose oxidase-coated carbon fiber electrodesApplied Surface Science, 2012
- Electrospun nanomaterials for ultrasensitive sensorsMaterials Today, 2010
- Electrospinning: A fascinating fiber fabrication techniqueBiotechnology Advances, 2010
- Glucose and urea biosensors based on all solid-state PVC–NH2 membrane electrodesAnalytica Chimica Acta, 2002
- A Biochemo-Mechanical System Consisting of Polyampholyte Gels with Coimmobilized Glucose Oxidase and UreaseLangmuir, 2001
- Molecular Sensors and Sensor Arrays Based on Polyaniline MicrotubulesAnalytical Chemistry, 1999
- Biosensors based on light-addressable potentiometric sensors for urea, penicillin and glucoseAnalytica Chimica Acta, 1998
- Application of an Acid Urease to Wine: Determination of Trace Urea in WineJournal of Food Science, 1990
- An enzyme electrode for the amperometric determination of glucoseAnalytica Chimica Acta, 1973