Pinar Camurlu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pinar Camurlu has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
- Roxana-Mihaela Apetrei
Akdeniz University, Department of Chemistry, 07058 Antalya, Turkey; 'Dunarea de Jos' University of Galati, Domneasca Street, 47, Galati RO-800008, Romania
14 shared publications Levent Toppare
The Center for Solar Energy Research and Application (GUNAM)
13 shared publications- Levent Toppare
Department of Polymer Science and Technology, Middle East Technical University, Ankara, Turkey
13 shared publications Nese Guven
Department of Chemistry Akdeniz University 07058 Antalya Turkey
12 shared publicationsCemil Gültekin
Akdeniz University, Department of Chemistry , Antalya , Turkey
6 shared publicationsBaris Yucel
5 shared publications
Latest Publications
- Open Access
- 31 January 2025
- Published by Izmir UOD in Scientific Research Communications
- Vol. 5 (1) , 39-58
New Amperometric Glucose Biosensors Based On Nafion Nanofibers
In this study, we present new amperometric glucose biosensorsbased on Nafion nanofibers. Nafion possesses a number of desirable properties, including stability, thermal, mechanical, physio-chemical and biocompatibility, which make it a competitive polymer for use in glucose biosensors. Nafion nanofibers were produced using a low-cost electrospinning method, and their morphology was characterized via scanning electron microscopy (SEM). The biosensors were fabricated by loading glucose oxidase (GOx) and GOx-AuNPs (10 nm) on the Nafion-Cellulose Acetate nanofibers(Nafion-CA Nfs) (461.53 ± 30.34 nm) on the surface of a platinum electrode, followed by cross-linking using glutaraldehyde. The biosensors operating at 0.6 V demonstrated lower LODs with wider linear ranges, enhanced stability, elevated sensitivity, and improved selectivity. For Pt/Nafion-CA NFs/GOx biosensor demonstrated remarkable sensitivity, with values of 68.67 μA.mM-1cm-² and 18.38 μA.mM-1.cm-², respectively, and a limit of detection (LOD) of 1.36 μM. Meanwhile, the Pt/Nafion-CA NFs/ GOx-AuNPsbiosensor achieved sensitivities of 55.56 μA.mM-1.cm² and 28.49 μA/mM·cm², respectively. It also exhibited a broad linear range of up to 12.81 mM and an LOD of 10.8 μM, with no observable interference effects. The present studies highlight the potential of Nafion nanofibersas a suitable matrix for immobilizingGOx and GOx-AuNPs, thereby demonstrating their viability as interference-free, easy-to-use sensors with good sensitivity, LOD and stability for commercialization.
- 31 January 2025
- Published by Izmir UOD in Scientific Research Communications
- Vol. 5 (1) , 39-58
Open AccessNew Amperometric Glucose Biosensors Based On Nafion Nanofibers
In this study, we present new amperometric glucose biosensorsbased on Nafion nanofibers. Nafion possesses a number of desirable properties, including stability, thermal, mechanical, physio-chemical and biocompatibility, which make it a competitive polymer for use in glucose biosensors. Nafion nanofibers were produced using a low-cost electrospinning method, and their morphology was characterized via scanning electron microscopy (SEM). The biosensors were fabricated by loading glucose oxidase (GOx) and GOx-AuNPs (10 nm) on the Nafion-Cellulose Acetate nanofibers(Nafion-CA Nfs) (461.53 ± 30.34 nm) on the surface of a platinum electrode, followed by cross-linking using glutaraldehyde. The biosensors operating at 0.6 V demonstrated lower LODs with wider linear ranges, enhanced stability, elevated sensitivity, and improved selectivity. For Pt/Nafion-CA NFs/GOx biosensor demonstrated remarkable sensitivity, with values of 68.67 μA.mM-1cm-² and 18.38 μA.mM-1.cm-², respectively, and a limit of detection (LOD) of 1.36 μM. Meanwhile, the Pt/Nafion-CA NFs/ GOx-AuNPsbiosensor achieved sensitivities of 55.56 μA.mM-1.cm² and 28.49 μA/mM·cm², respectively. It also exhibited a broad linear range of up to 12.81 mM and an LOD of 10.8 μM, with no observable interference effects. The present studies highlight the potential of Nafion nanofibersas a suitable matrix for immobilizingGOx and GOx-AuNPs, thereby demonstrating their viability as interference-free, easy-to-use sensors with good sensitivity, LOD and stability for commercialization.
- 2 January 2024
- Published by Wiley in ChemistrySelect
- Vol. 9 (1)
Discriminative detection of glucose and urea with a composite polymer nanofiber based matrix
Detection and quantification of glucose and urea are fundamental in medical analysis, real‐time monitoring, and point of care analysis. However, such analyses generally require sophisticated instrumentation and specialized personnel. Furthermore, discriminative detection of multiple analytes is often necessary for treatment and diagnosis. To address this challenge, this study describes a proof‐of‐concept for discriminative sensitive amperometric detection of both analytes. This was achieved by the fabrication of a polymer‐MWCNTs composite nanofiber matrix upon which glucose oxidase (GOD) and urease were co‐immobilized to allow detection of the corresponding substrates (glucose and urea). The (PAN(−MWCNTs)/Urease‐GOD) biosensor showed good performance in: (i) glucose biosensing with sensitivity of 31±5 μAmM −2 cm −2 within an extended linear range (0.1–5.0 mM) and a limit of detection of 3.7 μM, and (ii) urea detection at very low concentration (4–30 and 30–90 μM) with sensitivity up to 350±19 μAmM −2 cm −2 and very low LOD (0.1 μM). The analogous mono‐enzyme platform for urea detection (PAN(−MWCNTs)/Urease) showed very similar performance as the bi‐enzyme sensor, suggesting little to no influence of co‐immobilization on Urease activity, thus confirming that the two catalytic processes are independent of each other. The biosensors exhibited high accuracy in the detection of both analytes (at normal and pathological levels) in human serum, thus proving that the biosensor described herein can have practical applications in healthcare and remote patient monitoring.
- 2 January 2024
- Published by Wiley in ChemistrySelect
- Vol. 9 (1)
Discriminative detection of glucose and urea with a composite polymer nanofiber based matrix
Detection and quantification of glucose and urea are fundamental in medical analysis, real‐time monitoring, and point of care analysis. However, such analyses generally require sophisticated instrumentation and specialized personnel. Furthermore, discriminative detection of multiple analytes is often necessary for treatment and diagnosis. To address this challenge, this study describes a proof‐of‐concept for discriminative sensitive amperometric detection of both analytes. This was achieved by the fabrication of a polymer‐MWCNTs composite nanofiber matrix upon which glucose oxidase (GOD) and urease were co‐immobilized to allow detection of the corresponding substrates (glucose and urea). The (PAN(−MWCNTs)/Urease‐GOD) biosensor showed good performance in: (i) glucose biosensing with sensitivity of 31±5 μAmM −2 cm −2 within an extended linear range (0.1–5.0 mM) and a limit of detection of 3.7 μM, and (ii) urea detection at very low concentration (4–30 and 30–90 μM) with sensitivity up to 350±19 μAmM −2 cm −2 and very low LOD (0.1 μM). The analogous mono‐enzyme platform for urea detection (PAN(−MWCNTs)/Urease) showed very similar performance as the bi‐enzyme sensor, suggesting little to no influence of co‐immobilization on Urease activity, thus confirming that the two catalytic processes are independent of each other. The biosensors exhibited high accuracy in the detection of both analytes (at normal and pathological levels) in human serum, thus proving that the biosensor described herein can have practical applications in healthcare and remote patient monitoring.
- 1 October 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (10) , 107503
Ultrasensitive Catechol Detection via Core-Shell Nanofibers: Effect of Type of Conducting Polymer and MWCNT Reinforcement
The detection of phenols is one of the main research directions due to impact of phenols on human life. Herein, novel biosensing matrices based on pristine and composite (including MWCNTs) electrospun nanofibers coated with conducting polymers (poly(3,4-ethylenedioxythiphene (PEDOT) or polypyrrole (PPy)) were employed for immobilization of Tyrosinase enzyme and further evaluated for phenol detection. The current study is meant to provide a comparison between the two conducting polymers in terms of electron transfer and biocompatibility with the chosen enzyme, as resulted from analytical characterization of the biosensor and analysis of Michaelis-Menten behaviour. The developed biosensors (Pt/PAN(-MWCNTs)/PEDOT NFs/PPO and Pt/PAN(-MWCNTs)/PPy NFs/PPO) displayed high sensitivity values of 6846.83 and 10364 μA mM−1.cm−2 within linear ranges of 5.0 − 1.0 × 10−5 and 5.0 − 1.0 × 10−7 M, with limit of detection values in the nanomolar range (1.14 and 4.04 × 10−7 M) depending on the polymer employed (PEDOT and PPy, respectively). Given the nanostructured conducting matrix based on the synergistic effect between MWCNTs and CPs and the principle of detection employed, the analytical parameters of the current study are competent in catechol detection. In addition, the platform screened possible interferences allowing accurate detection of trace amounts of phenolics in spiked water samples.
- 1 October 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (10) , 107503
Ultrasensitive Catechol Detection via Core-Shell Nanofibers: Effect of Type of Conducting Polymer and MWCNT Reinforcement
The detection of phenols is one of the main research directions due to impact of phenols on human life. Herein, novel biosensing matrices based on pristine and composite (including MWCNTs) electrospun nanofibers coated with conducting polymers (poly(3,4-ethylenedioxythiphene (PEDOT) or polypyrrole (PPy)) were employed for immobilization of Tyrosinase enzyme and further evaluated for phenol detection. The current study is meant to provide a comparison between the two conducting polymers in terms of electron transfer and biocompatibility with the chosen enzyme, as resulted from analytical characterization of the biosensor and analysis of Michaelis-Menten behaviour. The developed biosensors (Pt/PAN(-MWCNTs)/PEDOT NFs/PPO and Pt/PAN(-MWCNTs)/PPy NFs/PPO) displayed high sensitivity values of 6846.83 and 10364 μA mM−1.cm−2 within linear ranges of 5.0 − 1.0 × 10−5 and 5.0 − 1.0 × 10−7 M, with limit of detection values in the nanomolar range (1.14 and 4.04 × 10−7 M) depending on the polymer employed (PEDOT and PPy, respectively). Given the nanostructured conducting matrix based on the synergistic effect between MWCNTs and CPs and the principle of detection employed, the analytical parameters of the current study are competent in catechol detection. In addition, the platform screened possible interferences allowing accurate detection of trace amounts of phenolics in spiked water samples.
- 14 December 2022
- Published by Elsevier in Enzyme and Microbial Technology
- Vol. 164, 110178
Highly sensitive detection of glucose via glucose oxidase immobilization onto conducting polymer-coated composite polyacrylonitrile nanofibers
- 14 December 2022
- Published by Elsevier in Enzyme and Microbial Technology
- Vol. 164, 110178
Highly sensitive detection of glucose via glucose oxidase immobilization onto conducting polymer-coated composite polyacrylonitrile nanofibers
- 14 July 2022
- Published by Wiley in ChemBioChem
- Vol. 23 (17) , e202200139
Trace‐Level Phenolics Detection Based on Composite PAN‐MWCNTs Nanofibers
In view of major concerns regarding toxicity (genotoxic, mutagenic, hepatotoxic) of phenolics, there is an on‐going necessity for sensitive and accurate analytical procedures for detection and measurements in environmental field, water, and food quality control. The current study proposes composite polyacrylonitrile nanofibrous assemblies enriched with multi‐wall carbon nanotubes (PAN‐MWCNTs NFs) as suitable immobilization platforms for cross‐linking of tyrosinase in detection of both diphenols and monophenols, which are of much interest in water contamination. The prepared biosensor (Pt/PAN‐MWCNTs/Tyr) showed high sensitivity in catechol detection (362.5 mA/M.cm2) and moderate sensitivity for the two monophenols (phenol, p‐chlorophenol) with 14.79 and 25.46 mA/M.cm2, respectively. The LOD values of the sensor were in the nanomolar range: 4.42×10−9, 4.06×10−7 and 1.05×10−7 M for catechol, phenol and p‐chlorophenol, respectively, allowing detection of trace amounts of phenolics in spiked water samples.
- 14 July 2022
- Published by Wiley in ChemBioChem
- Vol. 23 (17) , e202200139
Trace‐Level Phenolics Detection Based on Composite PAN‐MWCNTs Nanofibers
In view of major concerns regarding toxicity (genotoxic, mutagenic, hepatotoxic) of phenolics, there is an on‐going necessity for sensitive and accurate analytical procedures for detection and measurements in environmental field, water, and food quality control. The current study proposes composite polyacrylonitrile nanofibrous assemblies enriched with multi‐wall carbon nanotubes (PAN‐MWCNTs NFs) as suitable immobilization platforms for cross‐linking of tyrosinase in detection of both diphenols and monophenols, which are of much interest in water contamination. The prepared biosensor (Pt/PAN‐MWCNTs/Tyr) showed high sensitivity in catechol detection (362.5 mA/M.cm2) and moderate sensitivity for the two monophenols (phenol, p‐chlorophenol) with 14.79 and 25.46 mA/M.cm2, respectively. The LOD values of the sensor were in the nanomolar range: 4.42×10−9, 4.06×10−7 and 1.05×10−7 M for catechol, phenol and p‐chlorophenol, respectively, allowing detection of trace amounts of phenolics in spiked water samples.
- 1 February 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (2) , 020548
Biosensing Efficiency of Nanocarbon-Reinforced Polyacrylonitrile Nanofibrous Matrices
The reinforcement of polymer matrices with nanocarbon fillers is highly attractive for electrochemical biosensing (due to enhanced electrical conductivity). Further processing by electrospinning results in versatile nanofibrous mats. This study compares the biosensing performance of composite polyacrylonitrile nanofibers (PAN NFs) electrospun with different carbonaceous fillers (fullerene, carbon nanotubes, graphene). Morphological characterization of the composite NFs is performed by scanning electron microscopy (SEM) and correlated with the performance of the biosensing matrices. Glucose oxidase (GOD) is employed as model enzyme by immobilization through cross-linking. Optimum nanofiller content was evaluated at 2.0 wt%. for carboxyl functionalized-multiwall carbon nanotubes- NFs (highest sensitivity of 61.5 mAM −1 cm −2 and limit of detection (LOD) of 2.0 μ M), whilst reduced graphene oxide- NFs exhibited 49.3 mAM −1 cm −2 sensitivity with the lowest LOD of 1.6 μ M within the most extended linear range (up to 20 × 10 −3 M). Insignificant effect of interferent sugars led to real sample recovery close to 100%.
- 1 February 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (2) , 020548
Biosensing Efficiency of Nanocarbon-Reinforced Polyacrylonitrile Nanofibrous Matrices
The reinforcement of polymer matrices with nanocarbon fillers is highly attractive for electrochemical biosensing (due to enhanced electrical conductivity). Further processing by electrospinning results in versatile nanofibrous mats. This study compares the biosensing performance of composite polyacrylonitrile nanofibers (PAN NFs) electrospun with different carbonaceous fillers (fullerene, carbon nanotubes, graphene). Morphological characterization of the composite NFs is performed by scanning electron microscopy (SEM) and correlated with the performance of the biosensing matrices. Glucose oxidase (GOD) is employed as model enzyme by immobilization through cross-linking. Optimum nanofiller content was evaluated at 2.0 wt%. for carboxyl functionalized-multiwall carbon nanotubes- NFs (highest sensitivity of 61.5 mAM −1 cm −2 and limit of detection (LOD) of 2.0 μ M), whilst reduced graphene oxide- NFs exhibited 49.3 mAM −1 cm −2 sensitivity with the lowest LOD of 1.6 μ M within the most extended linear range (up to 20 × 10 −3 M). Insignificant effect of interferent sugars led to real sample recovery close to 100%.
- 1 February 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (2) , 026511
Fast Switching Triphenylamine-Based Electrochromic Polymers with Fluorene Core: Electrochemical Synthesis and Optoelectronic Properties
Most of the triarylamine-based electrochromic polymers are achieved through arylamine-based oxidative coupling reactions where the electrochromic properties of the polymer could only be realized after fabrication of the film on optically transparent electrodes. Electrochemical polymerization, on the other hand, is an in situ polymerization method which offers synthesis of the polymer and fabrication of the films on the electrode surface simultaneously. In this study two new triphenylamine monomers ( TPAFLA and TPAFLS ) having fluorene core were synthesized and successfully electrochemically polymerized. The electrogenerated polymer films exhibited strong color changes ( P(TPAFLA): yellow, orange, green, deep blue, P(TPAFLS): pale yellow, pale blue) and rapid switching responses ( P(TPAFLA) :1.61 s at 362 nm, P(TPAFLS) :0.69 s at 390 nm) and high coloration efficiency ( P(TPAFLA) :114 cm 2 C −1 , P(TPAFLS) :192 cm 2 C −1 ) compared to other triphenylamine derivatives. Furthermore, electrochemical copolymerization of TPAFLA with 3,4-ethylenedioxythiophene (EDOT) was successfully achieved for the first time and the copolymer revealed significantly lowered band gap with remarkably enlarged color palette (violet, yellow, green, light blue and blue).
- 1 February 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (2) , 026511
Fast Switching Triphenylamine-Based Electrochromic Polymers with Fluorene Core: Electrochemical Synthesis and Optoelectronic Properties
Most of the triarylamine-based electrochromic polymers are achieved through arylamine-based oxidative coupling reactions where the electrochromic properties of the polymer could only be realized after fabrication of the film on optically transparent electrodes. Electrochemical polymerization, on the other hand, is an in situ polymerization method which offers synthesis of the polymer and fabrication of the films on the electrode surface simultaneously. In this study two new triphenylamine monomers ( TPAFLA and TPAFLS ) having fluorene core were synthesized and successfully electrochemically polymerized. The electrogenerated polymer films exhibited strong color changes ( P(TPAFLA): yellow, orange, green, deep blue, P(TPAFLS): pale yellow, pale blue) and rapid switching responses ( P(TPAFLA) :1.61 s at 362 nm, P(TPAFLS) :0.69 s at 390 nm) and high coloration efficiency ( P(TPAFLA) :114 cm 2 C −1 , P(TPAFLS) :192 cm 2 C −1 ) compared to other triphenylamine derivatives. Furthermore, electrochemical copolymerization of TPAFLA with 3,4-ethylenedioxythiophene (EDOT) was successfully achieved for the first time and the copolymer revealed significantly lowered band gap with remarkably enlarged color palette (violet, yellow, green, light blue and blue).
- 1 September 2021
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 128, 112270
Next step in 2nd generation glucose biosensors: Ferrocene-loaded electrospun nanofibers
- 1 September 2021
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 128, 112270
Next step in 2nd generation glucose biosensors: Ferrocene-loaded electrospun nanofibers
- 1 August 2021
- Published by Elsevier in Bioelectrochemistry
- Vol. 140, 107751
Facile copper-based nanofibrous matrix for glucose sensing: Eenzymatic vs. non-enzymatic
- 1 August 2021
- Published by Elsevier in Bioelectrochemistry
- Vol. 140, 107751
Facile copper-based nanofibrous matrix for glucose sensing: Eenzymatic vs. non-enzymatic
- 27 May 2021
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 168 (6) , 067513
Functional Biosensing Platform for Urea Detection: Copolymer of Fc-Substituted 2,5-di(thienyl)pyrrole and 3,4-ethylenedioxythiophene
Biosensing devices for urea detection have become extensively researched as the analysis of urea levels is imperative in biological fluids indicating disorders of renal, hepatic, nervous and blood circulatory systems. The current work describes the development of two biosensing platforms for urea based on electrochemical deposition of ferrocene-substituted 2,5-di(thienyl)pyrrole (SNS-Fc) and copolymerization with 3,4-ethylenedioxythiophene (EDOT) (SNS-Fc-co-EDOT) followed by coupling with multi-wall carbon nanotubes (MWCNTs) and immobilization of Urease (Urs) through cross-linking. Optimum operational parameters (pH, applied potential) and design parameters (enzyme units, cross-linker concentration) were thoroughly investigated. The analytical comparison between P(SNS-Fc)/CNT/Urease and P(SNS-Fc-co-EDOT)/CNT/Urease showed a linear range between 0.01–0.20 and 0.01–0.15 mM, respectively with superior sensitivity (13.49 mAM −2 cm −2 ) and LOD (1.9 μ M) for the latter. Little to no interference was observed leading to accurate urea detection in real samples.
- 27 May 2021
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 168 (6) , 067513
Functional Biosensing Platform for Urea Detection: Copolymer of Fc-Substituted 2,5-di(thienyl)pyrrole and 3,4-ethylenedioxythiophene
Biosensing devices for urea detection have become extensively researched as the analysis of urea levels is imperative in biological fluids indicating disorders of renal, hepatic, nervous and blood circulatory systems. The current work describes the development of two biosensing platforms for urea based on electrochemical deposition of ferrocene-substituted 2,5-di(thienyl)pyrrole (SNS-Fc) and copolymerization with 3,4-ethylenedioxythiophene (EDOT) (SNS-Fc-co-EDOT) followed by coupling with multi-wall carbon nanotubes (MWCNTs) and immobilization of Urease (Urs) through cross-linking. Optimum operational parameters (pH, applied potential) and design parameters (enzyme units, cross-linker concentration) were thoroughly investigated. The analytical comparison between P(SNS-Fc)/CNT/Urease and P(SNS-Fc-co-EDOT)/CNT/Urease showed a linear range between 0.01–0.20 and 0.01–0.15 mM, respectively with superior sensitivity (13.49 mAM −2 cm −2 ) and LOD (1.9 μ M) for the latter. Little to no interference was observed leading to accurate urea detection in real samples.