Abstract
A 2 nV/√Hz and 10 fA/√Hz at 1-Hz ultralow noise preamplifier is designed to improve the sensitivity of the induction magnetometer (IM) from 0.1 Hz to 10 kHz. Meanwhile, the noise characteristics of IM are analyzed and distinguished. A novel optimization method to find the minimum length of the core under the required noise level and the limited IM weight is proposed. Furthermore, an optimal IM prototype from 0.1 Hz to 10 kHz is developed with the noise level of 1 pT/√Hz at 1 Hz and 1.5 fT/√Hz at 2 kHz. The length is only 360 mm and the weight is 1.5 kg. The measurement results of the IM also confirm the theoretical noise model and the optimization method.Keywords
Funding Information
- National Natural Science Foundation of China (41374186)
- High-Tech Research and Development Program (863 Program) of China (2014AA093407)
This publication has 20 references indexed in Scilit:
- Adaptive Backtracking Search Algorithm for Induction Magnetometer OptimizationIEEE Transactions on Magnetics, 2014
- Very Low 1/f Noise and Radiation-Hardened CMOS Preamplifier for High-Sensitivity Search Coil MagnetometersIEEE Sensors Journal, 2012
- A Three-Axial Search Coil Magnetometer Optimized for Small Size, Low Power, and Low FrequenciesIEEE Sensors Journal, 2010
- Principle and Performance of a Dual-Band Search Coil Magnetometer: A New Instrument to Investigate Fluctuating Magnetic Fields in SpaceIEEE Sensors Journal, 2009
- The Search Coil Magnetometer for THEMISSpace Science Reviews, 2008
- Improvements on the Design of Search Coil Magnetometer for Space ExperimentsSensor Letters, 2007
- An optimized low-frequency three-axis search coil magnetometer for space researchReview of Scientific Instruments, 2005
- Compact room-temperature induction magnetometer with superconducting quantum interference device level field sensitivityReview of Scientific Instruments, 2003
- A calibration facility for search coil magnetometersMeasurement Science and Technology, 2002
- Optimization Theory for Induction-Coil Magnetometers at Higher FrequenciesIEEE Transactions on Geoscience Electronics, 1979