Noninvasive Cardiac Output Measurement in Heart Failure Subjects on Circulatory Support
Authors:
- Rob PhillipsRPRob Phillips
- Peter LichtenthalPLPeter Lichtenthal
- Julie SlonigerJSJulie Sloniger
- Darryl BurstowDBDarryl Burstow
- Malcolm WestMWMalcolm West
- Jack CopelandJCJack Copeland
- 1 March 2009
- journal article
- review article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 108 (3) , 881-886
Abstract
Pulmonary artery catheter (PAC) thermodilution is commonly used in the perioperative cardiac surgical intensive care unit for measurement and management of central hemodynamics despite questions about effectiveness, difficulty of use, and safety. USCOM is a noninvasive continuous wave Doppler device for direct measurement of cardiac output (CO) and is an alternative to PAC. USCOM validation has predominantly been in the cardiac surgical intensive care unit against PAC, despite the recognized limitations in reliability of the method. We compared USCOM CO measurements with the CardioWest, an orthotopic total artificial heart (TAH), in heart failure (HF) subjects during controlled interventions. CO, stroke volume (SV), and heart rate (HR) were measured in a blinded fashion using the CardioWest and the USCOM device in TAH HF patients. Five-hundred eight paired measures from 18 examinations of seven subjects were acquired as flow was varied by the CardioWest controller. Bland-Altman analysis was used to compare agreement. Mean values and standard deviations (+/-SD) for CO, SV, and HR by CardioWest and USCOM were 7.33 +/- 0.46 and 7.34 +/- 0.51 L/min, 56.2 +/- 3.8 and 56.6 +/- 3.8 mL, and 131 +/- 3 and 130 +/- 4 bpm, respectively. CO ranged from 5.2 to 9.3 L/min. The mean differences between methods for CO, SV, and HR were -0.01 +/- 0.23 L/min, -0.34 +/- 1.97 mL, and 0.9 +/- 2.3 bpm, respectively, with mean percentage differences of -0.3%, -0.6%, and 0.7%. The percentage limits of agreement for CO, SV, and HR were 6.4%, 7.1%, and 3.6%. USCOM is a feasible and accurate method for noninvasive measurement and monitoring of CO in TAH HF patients and may have a wider application in diagnosis and management of cardiovascular disease.Keywords
This publication has 26 references indexed in Scilit:
- Cardiac output estimation after off-pump coronary artery bypass: A comparison of two different techniquesAnnals of Cardiac Anaesthesia, 2007
- Non-Invasive Cardiac Output Determination by Two-Dimensional Independent Doppler During and After Cardiac SurgeryThe Annals of Thoracic Surgery, 2005
- Testing the Reliability of a New Ultrasonic Cardiac Output Monitor, the USCOM, by Using Aortic Flowprobes in Anesthetized DogsAnesthesia & Analgesia, 2005
- Cardiac Replacement with a Total Artificial Heart as a Bridge to TransplantationNew England Journal of Medicine, 2004
- Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac functionCritical Care Medicine, 2003
- Ventilation, Thermal Noise, and Errors in Cardiac Output Measurements after Cardiopulmonary BypassAnesthesiology, 1993
- Indicator amount, temperature, and intrinsic cardiac output affect thermodilution cardiac output accuracy and reproducibilityCritical Care Medicine, 1993
- Errors in the measurement of cardiac output by thermodilutionCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1993
- Underestimation of cardiac output by thermodilution in patients with tricuspid regurgitationThe American Journal of Medicine, 1989
- Method of assessing the reproducibility of blood flow measurement: factors influencing the performance of thermodilution cardiac output computers.Heart, 1986