Quantitative passive soil vapor sampling for VOCs – part 4: flow-through cell
- 21 March 2014
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 16 (5) , 1103-1111
Abstract
This paper presents a controlled experiment comparing several quantitative passive samplers for monitoring concentrations of volatile organic compound (VOC) vapors in soil gas using a flow-through cell. This application is simpler than conventional active sampling using adsorptive tubes because the flow rate does not need to be precisely measured and controlled, which is advantageous because the permeability of subsurface materials affects the flow rate and the permeability of geologic materials is highly variable. Using passive samplers in a flow-through cell, the flow rate may not need to be known exactly, as long as it is sufficient to purge the cell in a reasonable time and minimize any negative bias attributable to the starvation effect. An experiment was performed in a 500 mL flow-through cell using a two-factor, one-half fraction fractional factorial test design with flow rates of 80, 670 and 930 mL min−1 and sample durations of 10, 15 and 20 minutes for each of five different passive samplers (passive Automatic Thermal Desorption Tube, Radiello®, SKC Ultra, Waterloo Membrane Sampler™ and 3M™ OVM 3500). A Summa canister was collected coincident with each passive sampler and analyzed by EPA Method TO-15 to provide a baseline for comparison of the passive sampler concentrations. The passive sampler concentrations were within a factor of 2 of the Summa canister concentrations in 32 of 35 cases. Passive samples collected at the low flow rate and short duration showed low concentrations, which is likely attributable to insufficient purging of the cell after sampler placement.Keywords
This publication has 15 references indexed in Scilit:
- Polydimethylsiloxane-based permeation passive air sampler. Part II: Effect of temperature and humidity on the calibration constantsJournal of Chromatography A, 2010
- High Purge Volume Sampling—A New Paradigm for Subslab Soil Gas MonitoringGroundwater Monitoring & Remediation, 2010
- Observed Spatial and Temporal Distributions of CVOCs at Colorado and New York Vapor Intrusion SitesGroundwater Monitoring & Remediation, 2009
- Spatial Variability of Soil‐Gas Concentrations near and beneath a Building Overlying Shallow Petroleum Hydrocarbon–Impacted SoilsGroundwater Monitoring & Remediation, 2009
- Passive sampling in environmental analysisJournal of Chromatography A, 2008
- Passive samplingTrAC Trends in Analytical Chemistry, 2002
- Evaluation of a Passive Sampler for Volatile Organic Compounds at ppb Concentrations, Varying Temperatures, and Humidities with 24-h Exposures. 2. Sampler PerformanceEnvironmental Science & Technology, 1999
- Measurement of volatile organic compounds in indoor air by a passive techniqueEnvironmental Technology, 1992
- Personal Monitoring Device for Gaseous ContaminantsAIHA Journal, 1973
- Elastic properties of reinforced solids: Some theoretical principlesJournal of the Mechanics and Physics of Solids, 1963