Advancing PPG-Based Continuous Blood Pressure Monitoring from a Generative Perspective
Open Access
- 4 November 2024
- conference paper
- Published by Association for Computing Machinery (ACM)
- p. 661-674
Abstract
Cuffless blood pressure (BP) monitoring is a critical task in the cardiovascular diseases (CVDs) domain, commonly based on Photoplethysmography (PPG) and Electrocardiogram (ECG) signals, providing foresight into cardiac health. While ECG often delivers better BP monitoring performance, the acquisition via straps and patches leads to a poor user experience. On the contrary, PPG enables continuous and convenient monitoring, but offers less informative references. A potential approach is to convert PPG signals into ECG signals, ensuring both high convenience and optimal accuracy. Converting PPG into ECG, however, involves a substantial reduction in inherent entropy, necessitating a thorough understanding of the process and specific techniques to guide the ECG generation. In this paper, we present a blood pressure monitoring framework that achieves ECG-level performance using solely the PPG signal. A diffusion model is introduced to conduct a selective ECG-targeted generative process with the condition of PPG. Based on our observation from the experimental investigation, a set of techniques is developed to significantly enhance the model's ability in generating high-quality ECG signals. Specifically, in the forward process, we employ an adaptive search module to adapt the QRS segment within the ECG waveform. In the reverse process, we propose the scale alignment and frequency alignment modules to better guide the generative process. Extensive experiments conducted on two public datasets and one self-collected dataset demonstrate the superior performance of our proposed framework, offering a groundbreaking perspective for PPG-based continuous blood pressure monitoring.Keywords
This publication has 58 references indexed in Scilit:
- Validation testing of five home blood pressure monitoring devices for the upper arm according to the ISO 81060-2:2018/AMD 1:2020 protocolJournal of Human Hypertension, 2023
- Global prevalence and burden of depressive and anxiety disorders in 204 countries and territories in 2020 due to the COVID-19 pandemicThe Lancet, 2021
- Multi‐model fusion of classifiers for blood pressure estimationIET Systems Biology, 2021
- A review of machine learning techniques in photoplethysmography for the non-invasive cuff-less measurement of blood pressureBiomedical Signal Processing and Control, 2020
- Blood pressure estimation from appropriate and inappropriate PPG signals using A whole-based methodBiomedical Signal Processing and Control, 2019
- Application of deep convolutional neural network for automated detection of myocardial infarction using ECG signalsInformation Sciences, 2017
- Oscillometric assessment of arterial stiffness in everyday clinical practiceHypertension Research, 2016
- Effect of changes in left ventricular anatomy and conduction velocity on the QRS voltage and morphology in left ventricular hypertrophy: a model studyJournal of Electrocardiology, 2010
- Spatial R wave amplitude changes during exercise: Relation with left ventricular ischemia and functionJACC, 1985
- Correlation between changes in R wave amplitude and left ventricular volume induced by rapid atrial pacingAmerican Heart Journal, 1984