Hui Ji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hui Ji has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Pengfei Zhou
School of Computing and Information, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
4 shared publications - Hanyu Zeng
Department of Informatics and Networked Systems, University of pittsburgh, Pittsburgh, Pennsylvania, USA
1 shared publication Pengfei Zhou
1 shared publicationWei Gao
1 shared publication
Latest Publications
- Open Access
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 902-916
ViPoser: Sparse-IMU Based Human Pose Estimation with Distilled Vision Foundation Priors
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 902-916
Open AccessViPoser: Sparse-IMU Based Human Pose Estimation with Distilled Vision Foundation Priors
- Open Access
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 1768-1770
Demo: Multi-Device Cuffless Blood Pressure Monitoring via PPG-to-ECG Generation
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 1768-1770
Open AccessDemo: Multi-Device Cuffless Blood Pressure Monitoring via PPG-to-ECG Generation
- 7 July 2026
- Published by Elsevier in Smart Health
- Vol. 41
P2Es: Physiology-conditioned diffusion for 12-lead ECG generation from PPG
- 7 July 2026
- Published by Elsevier in Smart Health
- Vol. 41
P2Es: Physiology-conditioned diffusion for 12-lead ECG generation from PPG
- Open Access
- 4 November 2024
- Published by Association for Computing Machinery (ACM)
- p. 661-674
Advancing PPG-Based Continuous Blood Pressure Monitoring from a Generative Perspective
Cuffless blood pressure (BP) monitoring is a critical task in the cardiovascular diseases (CVDs) domain, commonly based on Photoplethysmography (PPG) and Electrocardiogram (ECG) signals, providing foresight into cardiac health. While ECG often delivers better BP monitoring performance, the acquisition via straps and patches leads to a poor user experience. On the contrary, PPG enables continuous and convenient monitoring, but offers less informative references. A potential approach is to convert PPG signals into ECG signals, ensuring both high convenience and optimal accuracy. Converting PPG into ECG, however, involves a substantial reduction in inherent entropy, necessitating a thorough understanding of the process and specific techniques to guide the ECG generation. In this paper, we present a blood pressure monitoring framework that achieves ECG-level performance using solely the PPG signal. A diffusion model is introduced to conduct a selective ECG-targeted generative process with the condition of PPG. Based on our observation from the experimental investigation, a set of techniques is developed to significantly enhance the model's ability in generating high-quality ECG signals. Specifically, in the forward process, we employ an adaptive search module to adapt the QRS segment within the ECG waveform. In the reverse process, we propose the scale alignment and frequency alignment modules to better guide the generative process. Extensive experiments conducted on two public datasets and one self-collected dataset demonstrate the superior performance of our proposed framework, offering a groundbreaking perspective for PPG-based continuous blood pressure monitoring.
- 4 November 2024
- Published by Association for Computing Machinery (ACM)
- p. 661-674
Open AccessAdvancing PPG-Based Continuous Blood Pressure Monitoring from a Generative Perspective
Cuffless blood pressure (BP) monitoring is a critical task in the cardiovascular diseases (CVDs) domain, commonly based on Photoplethysmography (PPG) and Electrocardiogram (ECG) signals, providing foresight into cardiac health. While ECG often delivers better BP monitoring performance, the acquisition via straps and patches leads to a poor user experience. On the contrary, PPG enables continuous and convenient monitoring, but offers less informative references. A potential approach is to convert PPG signals into ECG signals, ensuring both high convenience and optimal accuracy. Converting PPG into ECG, however, involves a substantial reduction in inherent entropy, necessitating a thorough understanding of the process and specific techniques to guide the ECG generation. In this paper, we present a blood pressure monitoring framework that achieves ECG-level performance using solely the PPG signal. A diffusion model is introduced to conduct a selective ECG-targeted generative process with the condition of PPG. Based on our observation from the experimental investigation, a set of techniques is developed to significantly enhance the model's ability in generating high-quality ECG signals. Specifically, in the forward process, we employ an adaptive search module to adapt the QRS segment within the ECG waveform. In the reverse process, we propose the scale alignment and frequency alignment modules to better guide the generative process. Extensive experiments conducted on two public datasets and one self-collected dataset demonstrate the superior performance of our proposed framework, offering a groundbreaking perspective for PPG-based continuous blood pressure monitoring.
- Open Access
- 4 November 2024
- Published by Association for Computing Machinery (ACM)
- p. 879-881
Demo Abstract: Advancing PPG-Based Continuous Blood Pressure Monitoring from a Generative Perspective | Proceedings of the 22nd ACM Conference on Embedded Networked Sensor Systems
Cuffless blood pressure (BP) monitoring is a critical task in the cardiovascular diseases (CVDs) domain, commonly based on Photoplethysmography (PPG) and Electrocardiogram (ECG) signals. While ECG often delivers better BP monitoring performance, the acquisition via straps and patches leads to a poor user experience. On the contrary, PPG enables continuous and convenient monitoring, but offers less informative references. A potential approach is to convert PPG signals into ECG signals, ensuring both high convenience and optimal accuracy. Converting PPG into ECG, however, involves a substantial reduction in inherent entropy, necessitating a thorough understanding of the process and specific techniques to guide the ECG generation. In this demo, we present a blood pressure monitoring framework that achieves ECG-level performance using solely the PPG signal. A diffusion model is introduced to conduct a selective ECG-targeted generative process with the condition of PPG. Based on our observation from the experimental investigation, a set of techniques is developed to significantly enhance the model's ability in generating high-quality ECG signals. Specifically, in the forward process, we employ an adaptive search module to adapt the QRS segment within the ECG waveform. In the reverse process, we propose the scale alignment and frequency alignment modules to better guide the generative process. This framework bridges the gap between PPG convenience and ECG accuracy for improved BP monitoring.
- 4 November 2024
- Published by Association for Computing Machinery (ACM)
- p. 879-881
Open AccessDemo Abstract: Advancing PPG-Based Continuous Blood Pressure Monitoring from a Generative Perspective | Proceedings of the 22nd ACM Conference on Embedded Networked Sensor Systems
Cuffless blood pressure (BP) monitoring is a critical task in the cardiovascular diseases (CVDs) domain, commonly based on Photoplethysmography (PPG) and Electrocardiogram (ECG) signals. While ECG often delivers better BP monitoring performance, the acquisition via straps and patches leads to a poor user experience. On the contrary, PPG enables continuous and convenient monitoring, but offers less informative references. A potential approach is to convert PPG signals into ECG signals, ensuring both high convenience and optimal accuracy. Converting PPG into ECG, however, involves a substantial reduction in inherent entropy, necessitating a thorough understanding of the process and specific techniques to guide the ECG generation. In this demo, we present a blood pressure monitoring framework that achieves ECG-level performance using solely the PPG signal. A diffusion model is introduced to conduct a selective ECG-targeted generative process with the condition of PPG. Based on our observation from the experimental investigation, a set of techniques is developed to significantly enhance the model's ability in generating high-quality ECG signals. Specifically, in the forward process, we employ an adaptive search module to adapt the QRS segment within the ECG waveform. In the reverse process, we propose the scale alignment and frequency alignment modules to better guide the generative process. This framework bridges the gap between PPG convenience and ECG accuracy for improved BP monitoring.