Single-Ended Time Domain Fault Location Based on Transient Signal Measurements of Transmission Lines
Authors:
- Jian LuoJLJian Luo
- Yao LiuYLYao Liu
- Jiayong ZhongJZJiayong Zhong
- Lin ZhangLZLin Zhang
Top Cited Papers
- 1 March 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Protection and Control of Modern Power Systems
- Vol. 9 (2) , 61-74
Abstract
Precise fault location plays an important role in the reliability of modern power systems. With the increasing penetration of renewable energy sources, the power system experiences a decrease in system inertia and alterations in steady-state characteristics following a fault occurrence. Most existing single-ended phasor domain methods assume a certain impedance of the remote-end system or consistent current phases at both ends. These problems present challenges to the applicability of conventional phasor-domain location methods. This paper presents a novel single-ended time domain fault location method for single-phase-to-ground faults, one which fully considers the distributed parameters of the line model. The fitting of transient signals in the time domain is realized to extract the instantaneous amplitude and phase. Then, to eliminate the error caused by assumptions of lumped series resistance in the Bergeron model, an improved numerical derivation is presented for the distributed parameter line model. The instantaneous symmetrical components are extracted for decoupling and inverse transformation of three-phase recording data. Based on the above, the equation of instantaneous phase constraint is established to effectively identify the fault location. The proposed location method reduces the negative effects of fault resistance and the uncertainty of remote end parameters when relying on one-terminal data for localization. Additionally, the proposed fault analysis methods have the ability to adapt to transient processes in power systems. Through comparisons with existing methods in three different systems, the fault position is correctly identified within an error of 1%. Also, the results are not affected by sampling rates, data windows, fault inception angles, and load conditions.Keywords
This publication has 31 references indexed in Scilit:
- Single-ended multi-method phasor-based approach for optimized fault location on transmission linesElectric Power Systems Research, 2022
- A New Theory for Locating Line Fault in Power System: Theoretical PartIEEE Access, 2019
- The research of fault section location for distribution network based on transient feature extraction and fuzzy clustering2018
- Impedance-based fault location in transmission networks: theory and applicationIEEE Access, 2014
- Distributed parameter circuit model for transmission line2011
- Analysis of symmetrical components in time-domain2005
- An Intelligent and Efficient Fault Location and Diagnosis Scheme for Radial Distribution SystemsIEEE Transactions on Power Delivery, 2004
- A New Fault Location Algorithm Using Direct Circuit Analysis for Distribution SystemsIEEE Transactions on Power Delivery, 2004
- Fault location using the distributed parameter transmission line modelIEEE Transactions on Power Delivery, 2000
- Fast and accurate ADC testing via an enhanced sine wave fitting algorithmIEEE Transactions on Instrumentation and Measurement, 1997