Portable Nanohybrid Paper-Based Chemiresistive Sensor for Free Chlorine Detection
Authors:
Open Access
- 21 September 2020
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 5 (39) , 25209-25215
Abstract
Detecting the concentration of free chlorine is important for monitoring the quality of water. In this study, we report a nanohybrid paper-based chemiresistive sensor that can be used with smartphones to detect free chlorine ions. The sensor was fabricated using a simple and standardized coating process. The graphene and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) nanohybrid paper-based sensing device exhibited a more stable and intuitive response to free chlorine than that exhibited by the device using only PEDOT:PSS. The nanohybrid paper-based sensor was sensitive to free chlorine concentrations in a linear range of 0.1–500 ppm, and the limit of detection was 0.18 ppm. The sensor showed specificity for free chloride ions and detection capability in samples. The sensor was integrated as a module with an electric readout system, and the measured signals and results could be displayed in real time on a smartphone. Therefore, the proposed sensing platform is suitable owing to its portability, low cost, ease of use, and capability for on-site water quality measurement.Keywords
Funding Information
- Ministry of Science and Technology, Taiwan (MOST 108-2221-E-027-116)
This publication has 17 references indexed in Scilit:
- Disruption of the Electrical Conductivity of Highly Conductive Poly(3,4-ethylenedioxythiophene):Poly(styrene sulfonate) by HypochloriteThe Journal of Physical Chemistry B, 2013
- Graphene oxide/PEDOT:PSS and reduced graphene oxide/PEDOT:PSS hole extraction layers in organic photovoltaic cellsPhysica Status Solidi (a), 2012
- Flow injection analysis system based on amperometric thin-film transducers for free chlorine detection in swimming pool watersTalanta, 2009
- Electrochemical detection of free chlorine at highly boron-doped diamond electrodesJournal of Electroanalytical Chemistry, 2008
- The effect of pH on the electrochemical over-oxidation in PEDOT:PSS filmsSolid State Ionics, 2007
- Improved free chlorine amperometric sensor chip for drinking water applicationsAnalytica Chimica Acta, 2005
- Scientific importance, properties and growing applications of poly(3,4-ethylenedioxythiophene)Journal of Materials Chemistry, 2005
- Simple Miniaturized Amperometric Flow Cell for Monitoring Residual Chlorine in Tap WaterAnalytical Sciences, 2001
- Studies of a microelectrode sensor for monitoring chlorine in water suppliesAnalytica Chimica Acta, 1991
- Improvements in the N,N-diethyl-p-phenylenediamine method for the determination of free and combined residual chlorine through the use of FIATalanta, 1991