BIOMECHANICAL ANALYSIS OF INTERBODY AND POSTEROLATERAL FUSION WITH TRANSPEDICULAR SCREW FIXATION FOR SPONDYLOLISTHESIS: A FINITE ELEMENT STUDY
- 1 June 2008
- journal article
- Published by National Taiwan University in Biomedical Engineering: Applications, Basis and Communications
- Vol. 20 (3) , 145-151
Abstract
This study investigates and compares the mechanical response of interbody and posterolateral fusion along with the transpedicular screw fixation for the degenerative spondylolisthesis under different load conditions using finite element (FE) analysis. Image processing, computer aided design (CAD), and computer aided engineering techniques were applied to build a three-dimensional model of a functional spinal unit (L4–L5) with transpedicular screw fixation for the posterolateral fusion FE model. Additionally, the intervertebral disc was replaced by two cages to represent the interbody fusion FE model. A unit moment of 1 Nm was applied on the top of L4 in different directions to simulate the flexion, extension, lateral bending, and axial rotation, respectively. The lower of L5 was fixed in all directions for constraint. The simulated results revealed that using cages obviously decreased (13%–58%) the stress imposed upon the instrumentations. The stress concentration occurred at the locking nut on the transpedicular screw head, the middle part of the bone plate, and the thread of transpedicular screw near the head. These findings were comparable to clinical observations. With the limited data, our results suggested interbody fusion in combination with transpedicular screw fixation demonstrated less stress on the instrumentations than the posterolateral fusion with only transpedicular screw fixation.Keywords
This publication has 25 references indexed in Scilit:
- Treatment of Instability and SpondylolisthesisClinical Orthopaedics and Related Research, 2006
- The Indications for Interbody Fusion Cages in the Treatment of SpondylolisthesisSpine, 2005
- Degenerative SpondylolisthesisSpine, 2005
- Adult Low-Grade Acquired Spondylolytic SpondylolisthesisSpine, 2005
- Failure analysis of broken pedicle screws on spinal instrumentationMedical Engineering & Physics, 2005
- Lumbar interbody fusion: state-of-the-art technical advancesJournal of Neurosurgery: Spine, 2004
- Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operationsEuropean Spine Journal, 2002
- Lumbar Stenosis With SpondylolisthesisClinical Orthopaedics and Related Research, 2001
- Clinical and Radiological Results of PLIF for Degenerative SpondylolisthesisJournal of Musculoskeletal Research, 1998
- The Mechanical Function of the Lumbar Apophyseal JointsSpine, 1983