Heng-Liang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Heng-Liang Liu has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Ming-Tsung Sun
Chang-Gung University
3 shared publications Chun-Li Lin
Graduate Institute of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan
2 shared publications- Chun-Li Lin
Department of Mechanical Engineering, Chang Gung University, Tao-yuan, Taiwan
2 shared publications Hsiang-Hsi Hong
Chang Gung Memorial Hospital
2 shared publicationsAdrienne Hong
California North State University, College of Medicine, Elk Grove, California, United States of America
1 shared publication- Chang-Fu Kuo
Center for Artificial Intelligence in Medicine, Chang Gung Memorial Hospital, Taoyuan, Taiwan
1 shared publication
Latest Publications
- Open Access
- 26 November 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 108 (4) , 303-312
Minimizing Missed Diagnoses of Tibial Plateau Fractures
Background: Tibial plateau fractures represent a diverse group of intra-articular injuries that can be difficult to detect and characterize on initial imaging. The aim of the present study was to develop an artificial intelligence (AI) diagnostic tool for identifying tibial plateau fractures on radiographs. Methods: In this retrospective study, we analyzed radiographs that had been made from January 2018 to December 2020 for 1,809 patients, with an equal distribution of male and female adults. A total of 3,821 anteroposterior and lateral knee radiographs were evaluated with use of the EfficientNet B3 AI model, with computed tomography (CT) images being used as the ground truth. Evaluation metrics focused on the area under the receiver operating characteristic curve (AUC) and positive predictive values across different subgroups. Results: Our AI model attained AUCs of 0.98 and 0.97 for detecting tibial plateau fractures in the test and external validation datasets, respectively. Subgroup analysis revealed diverse positive predictive values across different Schatzker types and 3-column classifications. Conclusions: Our deep learning model exhibits newfound ability for identifying tibial plateau fractures. However, we encountered several limitations, such as imbalances among the sizes of various subgroups in the dataset and an inability to identify radiographs containing foreign objects or other defects. Level of Evidence: Diagnostic Level III . See Instructions for Authors for a complete description of levels of evidence.
- 26 November 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 108 (4) , 303-312
Open AccessMinimizing Missed Diagnoses of Tibial Plateau Fractures
Background: Tibial plateau fractures represent a diverse group of intra-articular injuries that can be difficult to detect and characterize on initial imaging. The aim of the present study was to develop an artificial intelligence (AI) diagnostic tool for identifying tibial plateau fractures on radiographs. Methods: In this retrospective study, we analyzed radiographs that had been made from January 2018 to December 2020 for 1,809 patients, with an equal distribution of male and female adults. A total of 3,821 anteroposterior and lateral knee radiographs were evaluated with use of the EfficientNet B3 AI model, with computed tomography (CT) images being used as the ground truth. Evaluation metrics focused on the area under the receiver operating characteristic curve (AUC) and positive predictive values across different subgroups. Results: Our AI model attained AUCs of 0.98 and 0.97 for detecting tibial plateau fractures in the test and external validation datasets, respectively. Subgroup analysis revealed diverse positive predictive values across different Schatzker types and 3-column classifications. Conclusions: Our deep learning model exhibits newfound ability for identifying tibial plateau fractures. However, we encountered several limitations, such as imbalances among the sizes of various subgroups in the dataset and an inability to identify radiographs containing foreign objects or other defects. Level of Evidence: Diagnostic Level III . See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 15 October 2019
- Published by Springer Nature in Research Square
Referring crown-to-root ratio and root surface area to assess periodontitis severity and prognosis
Background: Whether the linear crown-to-root ratio (CRR) decided by 3D and 2D clinical attachment loss (CAL) can be applied to evaluate the periodontitis severity and tooth prognosis was rarely examined. Materials: Sixty-six mandibular and maxillary single-rooted human premolars were surveyed by micro-computed tomography. CRRs at the levels of defined mild, moderate and severe periodontitis severity were analyzed. Statistical significance was confirmed by t -testes. Results: Along with the definitions, both the findings of coronal 25% root surface area (RSA) with CRR=1:1 corresponded to ≤3.0 mm linear radiographic bone loss (L-RBL) and 20% RSA with CRR=4:5 at L-RBL=1.6‒1.9 mm signified ≤15% L-RBL were categorized as mild periodontitis. Similarly, the results of coronal RSA≤52% with CRR≤3:2 at L-RBL≤5.0 mm and RSA=40% with CRR=5:4 at 4.0 mm L-RBL denoted 30% L-RBL were characterized moderate periodontitis. Additionally, relying on whether a 1.0mm connective tissue attachment (CTA) was included, CRR=1:1 at 25% L-RBL or CRR=4:3 at 35% L-RBL corresponded to a 25% clinical attachment loss (CAL), which could be used to distinguish a fair prognosis from a good prognosis. Either the level with 50% L-RBL at CRR=2:1, or the level with 50% CAL and 60% L-RBL at CRR=5:2 could be applied to differentiate a poor prognosis from a questionable prognosis. Conclusions: The periodontitis severity and tooth prognosis defined by 2015 academic classification could be evaluated according to a range of corresponding RSAs and CRRs. The length and morphology of the tapered roots and decreasing CTA enclosure partially explained the findings.
- 15 October 2019
- Published by Springer Nature in Research Square
Open AccessReferring crown-to-root ratio and root surface area to assess periodontitis severity and prognosis
Background: Whether the linear crown-to-root ratio (CRR) decided by 3D and 2D clinical attachment loss (CAL) can be applied to evaluate the periodontitis severity and tooth prognosis was rarely examined. Materials: Sixty-six mandibular and maxillary single-rooted human premolars were surveyed by micro-computed tomography. CRRs at the levels of defined mild, moderate and severe periodontitis severity were analyzed. Statistical significance was confirmed by t -testes. Results: Along with the definitions, both the findings of coronal 25% root surface area (RSA) with CRR=1:1 corresponded to ≤3.0 mm linear radiographic bone loss (L-RBL) and 20% RSA with CRR=4:5 at L-RBL=1.6‒1.9 mm signified ≤15% L-RBL were categorized as mild periodontitis. Similarly, the results of coronal RSA≤52% with CRR≤3:2 at L-RBL≤5.0 mm and RSA=40% with CRR=5:4 at 4.0 mm L-RBL denoted 30% L-RBL were characterized moderate periodontitis. Additionally, relying on whether a 1.0mm connective tissue attachment (CTA) was included, CRR=1:1 at 25% L-RBL or CRR=4:3 at 35% L-RBL corresponded to a 25% clinical attachment loss (CAL), which could be used to distinguish a fair prognosis from a good prognosis. Either the level with 50% L-RBL at CRR=2:1, or the level with 50% CAL and 60% L-RBL at CRR=5:2 could be applied to differentiate a poor prognosis from a questionable prognosis. Conclusions: The periodontitis severity and tooth prognosis defined by 2015 academic classification could be evaluated according to a range of corresponding RSAs and CRRs. The length and morphology of the tapered roots and decreasing CTA enclosure partially explained the findings.
- Open Access
- 8 March 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (3) , e0193894
Incompatible amount of 3-D and 2-D periodontal attachments on micro-CT scanned premolars
Micro-computed tomography (micro-CT) was employed to relate the root surface area (RSA) to the periodontal attachment levels (PALs) of extracted premolars to diagnose periodontitis. Single-rooted human maxillary and mandibular premolars 31 and 36, respectively, were surveyed by micro-CT and its associated software. RSA levels from the 1st to 10th mm, corono-apically, were analyzed using statistical t tests. The average root length (RL) and RSA of the maxillary and mandibular premolars were significantly different (p < 0.05). Both premolars demonstrated a non-significant RSA percentage comparison at the evaluated PALs. For the 30% coronal 2-D radiographic RL, the 3-D RSAs 3.77 mm and 3.99 mm apical to the cementoenamel junction (CEJ) were 39.48% and 40.65% for maxillary and mandibular premolars, respectively. At the 15% coronal 2-D RL, the 3-D RSA 2 mm apical to the CEJ of the premolars was approximately 21%. At the 50% coronal 2-D RL level, approximately 62% coronal 3-D RSA and 6.5 mm RL decreased. The amount of decrease of the RSA attachment is significant in every 2-mm measurement for both premolars. Sampling periodontal microbial pathogens based on the condition of 2-D radiographic bone and clinical attachment losses without considering 3-D RSA is potentially inadequate and may underestimate the severity of the periodontitis.
- 8 March 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (3) , e0193894
Open AccessIncompatible amount of 3-D and 2-D periodontal attachments on micro-CT scanned premolars
Micro-computed tomography (micro-CT) was employed to relate the root surface area (RSA) to the periodontal attachment levels (PALs) of extracted premolars to diagnose periodontitis. Single-rooted human maxillary and mandibular premolars 31 and 36, respectively, were surveyed by micro-CT and its associated software. RSA levels from the 1st to 10th mm, corono-apically, were analyzed using statistical t tests. The average root length (RL) and RSA of the maxillary and mandibular premolars were significantly different (p < 0.05). Both premolars demonstrated a non-significant RSA percentage comparison at the evaluated PALs. For the 30% coronal 2-D radiographic RL, the 3-D RSAs 3.77 mm and 3.99 mm apical to the cementoenamel junction (CEJ) were 39.48% and 40.65% for maxillary and mandibular premolars, respectively. At the 15% coronal 2-D RL, the 3-D RSA 2 mm apical to the CEJ of the premolars was approximately 21%. At the 50% coronal 2-D RL level, approximately 62% coronal 3-D RSA and 6.5 mm RL decreased. The amount of decrease of the RSA attachment is significant in every 2-mm measurement for both premolars. Sampling periodontal microbial pathogens based on the condition of 2-D radiographic bone and clinical attachment losses without considering 3-D RSA is potentially inadequate and may underestimate the severity of the periodontitis.
- 23 April 2010
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 38 (6) , 2004-2012
3D Micro-Crack Propagation Simulation at Enamel/Adhesive Interface Using FE Submodeling and Element Death Techniques
This study investigates micro-crack propagation at the enamel/adhesive interface using finite element (FE) submodeling and element death techniques. A three-dimensional (3D) FE macro-model of the enamel/adhesive/ceramic subjected to shear bond testing was generated and analyzed. A 3D micro-model with interfacial bonding structure was constructed at the upper enamel/adhesive interface where the stress concentration was found from the macro-model results. The morphology of this interfacial bonding structure (i.e., resin tag) was assigned based on resin tag geometry and enamel rod arrangement from a scanning electron microscopy micrograph. The boundary conditions for the micro-model were determined from the macro-model results. A custom iterative code combined with the element death technique was used to calculate the micro-crack propagation. Parallel experiments were performed to validate this FE simulation. The stress concentration within the adhesive occurred mainly at the upper corner near the enamel/adhesive interface and the resin tag base. A simulated fracture path was found at the resin tag base along the enamel/adhesive interface. A morphological observation of the fracture patterns obtained from in vitro testing corresponded with the simulation results. This study shows that the FE submodeling and element death techniques could be used to simulate the 3D micro-stress pattern and the crack propagation noted at the enamel/adhesive interface.
- 23 April 2010
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 38 (6) , 2004-2012
3D Micro-Crack Propagation Simulation at Enamel/Adhesive Interface Using FE Submodeling and Element Death Techniques
This study investigates micro-crack propagation at the enamel/adhesive interface using finite element (FE) submodeling and element death techniques. A three-dimensional (3D) FE macro-model of the enamel/adhesive/ceramic subjected to shear bond testing was generated and analyzed. A 3D micro-model with interfacial bonding structure was constructed at the upper enamel/adhesive interface where the stress concentration was found from the macro-model results. The morphology of this interfacial bonding structure (i.e., resin tag) was assigned based on resin tag geometry and enamel rod arrangement from a scanning electron microscopy micrograph. The boundary conditions for the micro-model were determined from the macro-model results. A custom iterative code combined with the element death technique was used to calculate the micro-crack propagation. Parallel experiments were performed to validate this FE simulation. The stress concentration within the adhesive occurred mainly at the upper corner near the enamel/adhesive interface and the resin tag base. A simulated fracture path was found at the resin tag base along the enamel/adhesive interface. A morphological observation of the fracture patterns obtained from in vitro testing corresponded with the simulation results. This study shows that the FE submodeling and element death techniques could be used to simulate the 3D micro-stress pattern and the crack propagation noted at the enamel/adhesive interface.
- 1 October 2009
- Published by National Taiwan University in Biomedical Engineering: Applications, Basis and Communications
- Vol. 21 (5) , 325-331
MICROMECHANICAL ANALYSIS AND CRACK PROPAGATION SIMULATION OF ENAMEL/CERAMIC ADHESIVE INTERFACE IN AN INCISOR VENEER USING THREE-DIMENSIONAL FINITE ELEMENT SUBMODELING AND ELEMENT DEACTIVATION APPROACHES
Retention of veneering materials to the tooth influences the survival rate in which depends primarily on an adequate adhesive bonded to enamel and ceramic substrates. Microleakages associated with resin monomers penetrating in enamel–etched porosities arise as the key issue to cause crack propagation and induce de-bonding in adhesive layer. The aim of this study is to investigate the micromechanical responses and crack propagation in a ceramic veneer adjacent to an incisal-overlapped incisor using the finite element (FE) submodeling and the element deactivation techniques. Section contours of an intact maxillary central incisor were acquired from microcomputed tomography (CT) to construct a three-dimensional (3D) FE macromodel considered with butt joint veneer design using mapping mesh approach. Ten loads from 10 to 100 N increments with 10 N were applied with an angulation of 60° to the tooth longitudinal axis at the incisal edge in the macromodel as the loading conditions to perform the simulations. The micromodel was constructed at an enamel–adhesive interface, where was the stress concentration area in the macromodel. The morphology and dimensions of the resin tags at the interface were assigned based on a SEM micrograph. Boundary conditions of the micromodel were determined from the macromodel results. An iterative code with the element deactivation technique was used while the local element stresses exceeding a self-testing tensile strength in adhesive layer to simulate the microcrack propagation. Stress concentration within the adhesive occurred at the enamel–adhesive interface of the lingual edge from the macromodels findings and at their resin tags base from the micromodels results. The maximum stress value in the micromodel exceeded the tensile strength (11.8 MPa) of resin cement when loading condition was 50 N. A simulated fracture path was found at the resin tags base along the enamel–adhesive interface from lingual to labial side. This study indicated that the FE submodeling and the element deactivation techniques could simulate efficiently the micromechanical responses and the microcrack propagation noted at the enamel–adhesive interface in the veneer system.
- 1 October 2009
- Published by National Taiwan University in Biomedical Engineering: Applications, Basis and Communications
- Vol. 21 (5) , 325-331
MICROMECHANICAL ANALYSIS AND CRACK PROPAGATION SIMULATION OF ENAMEL/CERAMIC ADHESIVE INTERFACE IN AN INCISOR VENEER USING THREE-DIMENSIONAL FINITE ELEMENT SUBMODELING AND ELEMENT DEACTIVATION APPROACHES
Retention of veneering materials to the tooth influences the survival rate in which depends primarily on an adequate adhesive bonded to enamel and ceramic substrates. Microleakages associated with resin monomers penetrating in enamel–etched porosities arise as the key issue to cause crack propagation and induce de-bonding in adhesive layer. The aim of this study is to investigate the micromechanical responses and crack propagation in a ceramic veneer adjacent to an incisal-overlapped incisor using the finite element (FE) submodeling and the element deactivation techniques. Section contours of an intact maxillary central incisor were acquired from microcomputed tomography (CT) to construct a three-dimensional (3D) FE macromodel considered with butt joint veneer design using mapping mesh approach. Ten loads from 10 to 100 N increments with 10 N were applied with an angulation of 60° to the tooth longitudinal axis at the incisal edge in the macromodel as the loading conditions to perform the simulations. The micromodel was constructed at an enamel–adhesive interface, where was the stress concentration area in the macromodel. The morphology and dimensions of the resin tags at the interface were assigned based on a SEM micrograph. Boundary conditions of the micromodel were determined from the macromodel results. An iterative code with the element deactivation technique was used while the local element stresses exceeding a self-testing tensile strength in adhesive layer to simulate the microcrack propagation. Stress concentration within the adhesive occurred at the enamel–adhesive interface of the lingual edge from the macromodels findings and at their resin tags base from the micromodels results. The maximum stress value in the micromodel exceeded the tensile strength (11.8 MPa) of resin cement when loading condition was 50 N. A simulated fracture path was found at the resin tags base along the enamel–adhesive interface from lingual to labial side. This study indicated that the FE submodeling and the element deactivation techniques could simulate efficiently the micromechanical responses and the microcrack propagation noted at the enamel–adhesive interface in the veneer system.
- 1 June 2009
- Vol. 11 (3) , 199-206
Damage accumulation simulations in the adhesive of enamel/ceramic interface using the FE submodelling and the element deactivation approaches.
To investigate the micromechanics and damage accumulation of the enamel/adhesive interface using sub-modelling and element deactivation methods. A finite element (FE) macromodel of the enamel/adhesive/ceramic interface subjected to shear bond testing was generated for mechanical analysis. The FE micromodel was constructed at the upper enamel/adhesive interface where stress concentration was found. The morphology of the micromechanical interlockings at the bonded interface was assigned based on a scanning electron micrograph. Boundary conditions of the micromodel were determined from the macromodel's results. Furthermore, an iterative code with the element deactivation method was used to calculate the microdamage accumulation. Parallel experiments were performed to validate the simulation. The micromodel results demonstrated that stress concentration within the adhesive mainly occurred at the upper corner near the enamel/adhesive interface and the base of the resin tags. A simulated fracture path was found at the base of the resin tags along the enamel/adhesive interface. The morphological observation of fracture patterns obtained from in vitro testing corresponded with the simulation results. This study showed that the FE submodelling and the element deactivation approaches could better simulate the micromechanical responses and the microdamage accumulation noted at the enamel/adhesive interface.
- 1 June 2009
- Vol. 11 (3) , 199-206
Damage accumulation simulations in the adhesive of enamel/ceramic interface using the FE submodelling and the element deactivation approaches.
To investigate the micromechanics and damage accumulation of the enamel/adhesive interface using sub-modelling and element deactivation methods. A finite element (FE) macromodel of the enamel/adhesive/ceramic interface subjected to shear bond testing was generated for mechanical analysis. The FE micromodel was constructed at the upper enamel/adhesive interface where stress concentration was found. The morphology of the micromechanical interlockings at the bonded interface was assigned based on a scanning electron micrograph. Boundary conditions of the micromodel were determined from the macromodel's results. Furthermore, an iterative code with the element deactivation method was used to calculate the microdamage accumulation. Parallel experiments were performed to validate the simulation. The micromodel results demonstrated that stress concentration within the adhesive mainly occurred at the upper corner near the enamel/adhesive interface and the base of the resin tags. A simulated fracture path was found at the base of the resin tags along the enamel/adhesive interface. The morphological observation of fracture patterns obtained from in vitro testing corresponded with the simulation results. This study showed that the FE submodelling and the element deactivation approaches could better simulate the micromechanical responses and the microdamage accumulation noted at the enamel/adhesive interface.
- 1 June 2008
- Published by National Taiwan University in Biomedical Engineering: Applications, Basis and Communications
- Vol. 20 (3) , 145-151
BIOMECHANICAL ANALYSIS OF INTERBODY AND POSTEROLATERAL FUSION WITH TRANSPEDICULAR SCREW FIXATION FOR SPONDYLOLISTHESIS: A FINITE ELEMENT STUDY
This study investigates and compares the mechanical response of interbody and posterolateral fusion along with the transpedicular screw fixation for the degenerative spondylolisthesis under different load conditions using finite element (FE) analysis. Image processing, computer aided design (CAD), and computer aided engineering techniques were applied to build a three-dimensional model of a functional spinal unit (L4–L5) with transpedicular screw fixation for the posterolateral fusion FE model. Additionally, the intervertebral disc was replaced by two cages to represent the interbody fusion FE model. A unit moment of 1 Nm was applied on the top of L4 in different directions to simulate the flexion, extension, lateral bending, and axial rotation, respectively. The lower of L5 was fixed in all directions for constraint. The simulated results revealed that using cages obviously decreased (13%–58%) the stress imposed upon the instrumentations. The stress concentration occurred at the locking nut on the transpedicular screw head, the middle part of the bone plate, and the thread of transpedicular screw near the head. These findings were comparable to clinical observations. With the limited data, our results suggested interbody fusion in combination with transpedicular screw fixation demonstrated less stress on the instrumentations than the posterolateral fusion with only transpedicular screw fixation.
- 1 June 2008
- Published by National Taiwan University in Biomedical Engineering: Applications, Basis and Communications
- Vol. 20 (3) , 145-151
BIOMECHANICAL ANALYSIS OF INTERBODY AND POSTEROLATERAL FUSION WITH TRANSPEDICULAR SCREW FIXATION FOR SPONDYLOLISTHESIS: A FINITE ELEMENT STUDY
This study investigates and compares the mechanical response of interbody and posterolateral fusion along with the transpedicular screw fixation for the degenerative spondylolisthesis under different load conditions using finite element (FE) analysis. Image processing, computer aided design (CAD), and computer aided engineering techniques were applied to build a three-dimensional model of a functional spinal unit (L4–L5) with transpedicular screw fixation for the posterolateral fusion FE model. Additionally, the intervertebral disc was replaced by two cages to represent the interbody fusion FE model. A unit moment of 1 Nm was applied on the top of L4 in different directions to simulate the flexion, extension, lateral bending, and axial rotation, respectively. The lower of L5 was fixed in all directions for constraint. The simulated results revealed that using cages obviously decreased (13%–58%) the stress imposed upon the instrumentations. The stress concentration occurred at the locking nut on the transpedicular screw head, the middle part of the bone plate, and the thread of transpedicular screw near the head. These findings were comparable to clinical observations. With the limited data, our results suggested interbody fusion in combination with transpedicular screw fixation demonstrated less stress on the instrumentations than the posterolateral fusion with only transpedicular screw fixation.