Long-term evaluation of anterior lens density after implantable collamer lens V4c implantation in patients with myopia over 40 years old
Open Access
- 28 June 2021
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 106 (11) , 1508-1513
Abstract
Purpose To investigate the long-term safety and efficacy of implantable collamer lens (ICL) V4c implantation and changes in the anterior lens density (ALD) in patients with myopia ≥40 years of age. Methods This prospective study included 104 eyes of 52 patients >40 years of age before ICL V4c implantation. Spherical equivalent (SE), uncorrected distance visual acuity, corrected distance visual acuity (CDVA), intraocular pressure, endothelial cell density, anterior chamber depth, anterior chamber volume and anterior chamber angle preoperatively, at 1 and 3 months, and at 3 years postoperatively were recorded. Pentacam HR was used to analyse ALD changes at a depth of 0.5, 1.0 and 1.5 mm within a 3 mm diameter range around the pupil’s centre. Results The overall follow-up was uneventful at 42±7.1 months; the safety index at last follow-up was 1.26±0.35 and the efficacy index was 0.91±0.41. No eye lost the Snellen line of CDVA, 76% of the eyes had an increase in CDVA for ≥1 line and 62% had an SE within ±0.50 dioptre. The increase in ALD at 0.5, 1 and 1.5 mm was 16.52%±10.46%, 16.72%±9.85% and 17.28%±11.93%, respectively. Preoperative, 1-month and 3-month postoperative ALDs showed correlations with SE and age, and ALD at last follow-up was correlated only with age. There was no correlation between ALD and any other parameters. Conclusion ICL V4c shows long-term safety and efficacy in people ≥40 years of age. ALD increased in such patients, which may be related to age and SE.Keywords
Funding Information
- Project of Shanghai Science and Technology (20410710100)
- Joint Research Project (SHDC12018103)
- Project of Shanghai Xuhui District Science and Technology (2020-015)
- National Natural Science Foundation of China (81770955)
- Clinical Research Plan of SHDC (SHDC2020CR1043B)
This publication has 19 references indexed in Scilit:
- Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lensClinical Ophthalmology, 2016
- Effect of hole size on fluid dynamics of a posterior-chamber phakic intraocular lens with a central perforation by using computational fluid dynamicsGraefe's Archive for Clinical and Experimental Ophthalmology, 2016
- Repeatability of lens densitometry using Scheimpflug imagingJournal of Cataract & Refractive Surgery, 2014
- Fluid dynamics simulation of aqueous humour in a posterior-chamber phakic intraocular lens with a central perforationGraefe's Archive for Clinical and Experimental Ophthalmology, 2011
- Membrane Association of Proteins in the Aging Human Lens: Profound Changes Take Place in the Fifth Decade of LifeInvestigative Ophthalmology & Visual Science, 2009
- Correlation of Nuclear Cataract Lens Density Using Scheimpflug Images with Lens Opacities Classification System III and Visual FunctionOphthalmology, 2009
- Crystalline Lens Optical Dysfunction through AgingOphthalmology, 2005
- United States Food and Drug Administration clinical trial of the Implantable Collamer Lens (ICL) for moderate to high myopiaOphthalmology, 2004
- Safety of posterior chamber phakic intraocular lenses for the correction of high myopiaOphthalmology, 2001
- Investigations on lens transparency and its disturbances by microdensitometric analyses of Scheimpflug photographsCurrent Eye Research, 1984