A novel method for incorporating respiratory-matched attenuation correction in the motion correction of cardiac PET–CT studies
Authors:
- Sarah J McQuaidSMSarah J McQuaid
- Tryphon LambrouTLTryphon Lambrou
- Brian F HuttonBHBrian F Hutton
- 13 April 2011
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (10) , 2903-2915
Abstract
Mismatches between PET and CT datasets due to respiratory effects can lead to artefactual perfusion defects. To overcome this, we have proposed a method of aligning a single CT with each frame of a gated PET study in a semi-automatic manner, incorporating a statistical shape model of the diaphragm and a rigid registration of the heart. This ensures that the structures that could influence the appearance of the reconstructed cardiac activity are correctly matched between emission and transmission datasets. When tested on two patient studies, it was found in both cases that attenuation correction using the proposed technique resulted in PET images that were closer to the gold standard of attenuation correction with a gated CT, compared with scenarios where only heart matching was considered (and not the diaphragm) or where no transformation was performed (i.e. where a single CT frame was used to attenuation-correct all PET frames). These preliminary results suggest that diaphragm matching between PET and CT improves the quantitative accuracy of reconstructed PET images and that the proposed method of using a statistical shape model to describe the diaphragm shape and motion, in combination with a rigid registration to determine respiratory-induced heart motion, is a feasible method of achieving this.Keywords
This publication has 18 references indexed in Scilit:
- Implementation of an Automated Respiratory Amplitude Gating Technique for PET/CT: Clinical EvaluationJournal of Nuclear Medicine, 2009
- Contrast enhanced 4D-CT imaging for target volume definition in pancreatic ductal adenocarcinomaRadiotherapy and Oncology, 2008
- Respiratory Motion Correction in 3-D PET Data With Advanced Optical Flow AlgorithmsIEEE Transactions on Medical Imaging, 2008
- CT-based attenuation correction in 82Rb-myocardial perfusion PET–CT: incidence of misalignment and effect on regional tracer distributionEuropean Journal of Nuclear Medicine and Molecular Imaging, 2007
- Frequent Diagnostic Errors in Cardiac PET/CT Due to Misregistration of CT Attenuation and Emission PET Images: A Definitive Analysis of Causes, Consequences, and CorrectionsJournal of Nuclear Medicine, 2007
- Respiration-Averaged CT for Attenuation Correction in Canine Cardiac PET/CTJournal of Nuclear Medicine, 2007
- Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PETPhysics in Medicine & Biology, 2005
- A generalized model for the conversion from CT numbers to linear attenuation coefficientsIEEE Transactions on Nuclear Science, 2003
- CT vs 68Ge attenuation correction in a combined PET/CT system: evaluation of the effect of lowering the CT tube currentEuropean Journal of Nuclear Medicine and Molecular Imaging, 2001
- Respiratory kinematics of the upper abdominal organs: A quantitative studyMagnetic Resonance in Medicine, 1992