Spontaneous fluctuations in the peripheral photoplethysmographic waveform: roles of arterial pressure and muscle sympathetic nerve activity
- 1 February 2012
- journal article
- clinical trial
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 302 (3) , H826-H836
Abstract
Assessment of spontaneous slow waves in the peripheral blood volume using the photoplethysmogram (PPG) has shown potential clinical value, but the physiological correlates of these fluctuations have not been fully elucidated. This study addressed the contribution of arterial pressure and muscle sympathetic nerve activity (MSNA) in beat-to-beat PPG variability in resting humans under spontaneous breathing conditions. Peripheral PPG waveforms were measured from the fingertip, earlobe, and toe in young and healthy individuals (n = 13), together with the arterial pressure waveform, electrocardiogram, respiration, and direct measurement of MSNA by microneurography. Cross-spectral coherence analysis revealed that among the PPG waveforms, low-frequency fluctuations (0.04–0.15 Hz) in the ear PPG had the highest coherence with arterial pressure (0.71 ± 0.15) and MSNA (0.44 ± 0.18, with a peak of 0.71 ± 0.16 at 0.10 ± 0.03 Hz). The normalized midfrequency powers (0.08–0.15 Hz), with an emphasis on the 0.1-Hz region, were positively correlated between MSNA and the ear PPG (r = 0.77, P = 0.002). Finger and toe PPGs had lower coherence with arterial pressure (0.35 ± 0.10 and 0.30 ± 0.11, respectively) and MSNA (0.33 ± 0.10 and 0.26 ± 0.10, respectively) in the LF band but displayed higher coherence between themselves (0.54 ± 0.09) compared with the ear (P < 0.001), which may suggest the dominance of regional vasomotor activities and a common sympathetic influence in the glabrous skin. These findings highlight the differential mechanisms governing PPG waveform fluctuations across different body sites. Spontaneous PPG variability in the ear includes a major contribution from arterial pressure and MSNA, which may provide a rationale for its clinical utility.Keywords
This publication has 44 references indexed in Scilit:
- Influence of the site of measurement on the ability of plethysmographic variability index to predict fluid responsivenessBritish Journal of Anaesthesia, 2011
- Contribution of arterial Windkessel in low-frequency cerebral hemodynamics during transient changes in blood pressureJournal of Applied Physiology, 2011
- Augmented photoplethysmographic low frequency waves at the onset of endotoxic shock in rabbitsPhysiological Measurement, 2010
- Muscle sympathetic nerve activity during intense lower body negative pressure to presyncope in humansThe Journal of Physiology, 2009
- Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patientsIntensive Care Medicine, 2007
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007
- Sympathetic neural hyperactivity and its normalization following unstable angina and acute myocardial infarctionClinical Science, 2004
- Autonomic Control of Skin Microvessels: Assessment by Power Spectrum of Photoplethysmographic WavesClinical Science, 1996
- An Efficient Algorithm for Spectral Analysis of Heart Rate VariabilityIEEE Transactions on Biomedical Engineering, 1986
- Thermoregulatory and rhythm‐generating mechanisms governing the sudomotor and vasoconstrictor outflow in human cutaneous nerves.The Journal of Physiology, 1980