Investigation of beam delivery time for synchrotron-based proton pencil beam scanning system with novel scanning mode
- 17 August 2022
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (17) , 175001
Abstract
Objective. To investigate synchrotron-based proton pencil beam scanning (PBS) beam delivery time (BDT) using novel continuous scanning mode. Approach. A BDT calculation model was developed for the Hitachi particle therapy system. The model was validated against the measured BDT of 36 representative clinical proton PBS plans with discrete spot scanning (DSS) in the current Hitachi proton therapy system. BDTs were calculated with the next generation using Mayo Clinic Florida system operating parameters for conventional DSS, and novel dose driven continuous scanning (DDCS). BDTs of DDCS with and without Break Spots were investigated. Main results. For DDCS without Break Spots, the use of Stop Ratio to control the transit dose largely reduced the beam intensity and consequently, severely prolonged the BDT. DDCS with Break Spots was able to maintain a sufficiently high beam intensity while controlling transit dose. In DDCS with Break Spots, tradeoffs were made between beam intensity and number of Break Spots. Therefore, BDT decreased with increased beam intensity but reached a plateau for beam intensity larger than 10 MU s −1 . Averaging over all clinical plans, BDT was reduced by 10% for DDCS with Break Spots compared to DSS. Significance. DDCS with Break Spots reduced BDT. DDCS has the potential to further reduce BDT under the ideal scenario which requests both stable beam intensity extraction and accurately modelling the transit dose. Further investigation is warranted.Keywords
This publication has 23 references indexed in Scilit:
- Technical Note: Using experimentally determined proton spot scanning timing parameters to accurately model beam delivery timeMedical Physics, 2017
- Proton Beam Radiotherapy and Concurrent Chemotherapy for Unresectable Stage III Non–Small Cell Lung CancerJAMA Oncology, 2017
- Effect of Intrafraction Prostate Motion on Proton Pencil Beam Scanning Delivery: A Quantitative AssessmentInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2013
- Particle Beam Scanning2011
- Commissioning of the discrete spot scanning proton beam delivery system at the University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, HoustonMedical Physics, 2009
- The M. D. Anderson proton therapy systemMedical Physics, 2009
- Time Dependence of Intrafraction Patient Motion Assessed by Repeat Stereoscopic ImagingInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Proton Therapy2006
- Intensity modulation methods for proton radiotherapyPhysics in Medicine & Biology, 1999
- The 200‐MeV proton therapy project at the Paul Scherrer Institute: Conceptual design and practical realizationMedical Physics, 1995