JDJingjing Michele Dougherty

Jingjing Michele Dougherty

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jingjing Michele Dougherty has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Early Clinical Outcomes and Local Control Following Spine Stereotactic Proton Ablative Radiotherapy (SPAR)

    by Jingjing M. Dougherty, Roman O. Kowalchuk, Daniel K. Ebner, Kenneth W. Merrell, Benjamin A. Johnson-Tesch, Jonathan M. Morris, William S. Harmsen, William G. Breen, Satomi Shiraishi, Matthew J. Iott, et al.


  • SPICE It Up: Technical Report of Hotspot Design for Volumetric Modulated Arc Therapy-Stereotactic Body Radiation Therapy in Early-Stage Non-Small Cell Lung Cancer

    by Bryan A. Johnson, Clayton N. Young, Katey M. Wert, Angela Chellini, Fantine Giap, Bradford S. Hoppe, Jingjing M. Dougherty

  • Hybrid LiDAR-RGB 3D surface reconstruction for collision avoidance in radiotherapy: a proof‑of‑concept phantom study

    by Jingjing M. Dougherty, Chris J. Beltran

    To evaluate a proof-of-concept three-dimensional surface reconstruction technique using a hybrid LiDAR and RGB sensor system with an open-source, GPU-accelerated pipeline. The goal is to generate photorealistic digital twins of phantom surfaces for integration into radiotherapy collision avoidance workflows. A portable Intel RealSense sensor was used to acquire synchronized depth and color images. Sensor performance, including depth accuracy, fill rate, and planar root mean square error, was evaluated to determine practical scan range. A reconstruction pipeline was implemented using the Open3D library with a voxel-based framework, signed distance function integration, ray casting, and color and depth-based simultaneous localization and mapping for pose tracking. Surface meshes were generated using the Marching Cubes algorithm. Validation involved scanning rectangular box phantoms and an anthropomorphic Rando phantom in a single circular motion. Reconstructed models were registered to CT-derived meshes using manual point picking and iterative closest point alignment. Accuracy was assessed using cloud-to-mesh distance metrics and compared to Poisson surface reconstruction. Highest accuracy was observed within the 0.3 to 2.0 m range. Dimensional differences for box models were within five millimeters. The Rando phantom showed a registration error of 1.8 mm and 100% theoretical overlap with the CT reference. Global mean signed distance was minus 0.32 mm with a standard deviation of 3.85 mm. This technique has strong potential to enables accurate, realistic surface modeling using low-cost, open-source tools and supports future integration into radiotherapy digital twin systems.

  • Open Access

    Digital twin creation of a proton therapy treatment environment with hybrid LiDAR and RGB 3D camera

    by Jingjing M. Dougherty, Erik J. Tryggestad, Chris J. Beltran

    Introduction: This study evaluates the feasibility of utilizing a commercial‐grade 3D LiDAR/RGB camera, combined with 3D reconstruction software, to create an accurate and hyper‐realistic digital model of a proton therapy treatment room. This reconstructed model aims to enhance collision avoidance strategies and improve 3D machine model accessibility. Utilization of a 3D LiDAR/RGB camera as a radiotherapy environment modeling has not been reported prior.Methods: To create a comprehensive 3D model of a half‐gantry proton therapy system, colored point cloud data was captured using the Matterport Pro 3 camera, a hybrid LiDAR and RGB imaging system with high‐resolution capabilities (134.2 MP), a 360° horizontal field of view, and 20 mm accuracy at 10 m. A total of 117 acquisition points, distributed across the treatment room with three camera heights, ensured complete coverage and minimal occlusions. Scanning, completed in under 3 hours, was monitored in real time using the Matterport App. Post‐scan processing involved denoising and converting the point cloud into 3D mesh structures using MeshLab, followed by refined pair‐wise iterative closest point (ICP) alignments. Textures and materials were assigned to reflect real‐world objects, and a ray‐tracing engine simulated realistic lighting in Blender. Animations illustrating the kinematics of the treatment couch and gantry were simulated in Blender for enhanced visualization.Results: The scanning process achieved complete data capture without missing information, attributed to strategic oversampling during data acquisition. The mean root mean square error (RMSE) of the ICP registration was 0.008 m. The validation process confirmed that the dimensions of the treatment couch within the digital model closely matched the actual measurements with less than 2 cm deviation, indicating high accuracy. The resulting digital twin provided a photorealistic and immersive representation of the proton therapy treatment room, serving as a valuable digital asset for various applications.Conclusion: It is possible to generate vendor‐independent and highly accurate 3D models of the proton treatment room environment with a commercial grade LiDAR/RGB camera to expand future research opportunities and education endeavors.


  • Open Access

    Hybrid LiDAR-RGB Surface Reconstruction for Collision Avoidance in Radiotherapy: An Proof‑of‑Concept Phantom Study

    by Jingjing Michele Dougherty, Chris Beltran

    Introduction: To evaluate a proof-of-concept three-dimensional surface reconstruction technique using a hybrid LiDAR and RGB sensor system with an open-source, GPU-accelerated pipeline. The goal is to generate photorealistic digital twins of phantom surfaces for integration into radiotherapy collision avoidance workflows. Methods: A portable Intel RealSense sensor was used to acquire synchronized depth and color images. Sensor performance, including depth accuracy, fill rate, and planar root mean square error, was evaluated to determine optimal scan range. A reconstruction pipeline was implemented using the Open3D library with a voxel-based framework, signed distance function integration, ray casting, and color and depth-based simultaneous localization and mapping for pose tracking. Surface meshes were generated using the Marching Cubes algorithm. Validation involved scanning rectangular box phantoms and an anthropomorphic Rando phantom in a single circular motion. Reconstructed models were registered to CT-derived meshes using manual point picking and iterative closest point alignment. Accuracy was assessed using cloud-to-mesh distance metrics and compared to Poisson surface reconstruction. Results: Highest accuracy was observed within the 0.3 to 2.0 meter range. Volume differences for box models were within five millimeters. The Rando phantom showed a registration error of 1.8 millimeters and full overlap with the CT reference. Mean signed distance was minus 0.32 millimeters with a standard deviation of 3.85 millimeters. Conclusions: This technique enables accurate, realistic surface modeling using low-cost, open-source tools and supports future integration into radiotherapy digital twin systems.

  • A Geant4 shielding design for the first US carbon multi-ion hybrid synchrotron facility

    by Jingjing M Dougherty, David Bolst, Keith M Furutani, Susanna Guatelli, Xiaoying Liang, Anatoly Rosenfeld, Chris J Beltran

    The Mayo Clinic Florida Integrated Oncology Building will be the home of the first spot-scanning only carbon/proton hybrid therapy system by Hitachi, Ltd. It will provide proton beams up to kinetic energies of 230 MeV and carbon beams up to 430 MeV n−1 for clinical deployment. To provide adequate radiation protection, the Geant4 (v10.6) Monte Carlo toolkit was utilized to quantify the ambient dose equivalent at a 10 mm depth (H*(10)) for photons and neutrons. To perform accurate calculations of the ambient dose equivalent, three-dimensional computer-aided design files of the entire planned facility were imported into Geant4, as well as certain particle system components such as the bending magnets, fast Faraday cup, and gantry. Particle fluence was scored using 60 cm diameter spheres, which were strategically placed throughout areas of interests. Analytical calculations were performed as first-pass design checks. Major shielding slabs were optimized using Geant4 simulations iteratively, with more than 20 alternative designs evaluated within Geant4. The 430 MeV n−1 carbon beams played the most significant role in concrete thickness Requirements. The primary wall thickness for the carbon fixed beam room is 4 meters. The presence of the proton gantry structure in the simulation caused the ambient dose equivalent to increase by around 67% at the maze entrance, but a decrease in the high energy beam transport corridor. All shielding primary and secondary goals for clinical operations were met per state regulation and national guidelines.


  • Investigation of beam delivery time for synchrotron-based proton pencil beam scanning system with novel scanning mode

    by Xiaoying Liang, Chunbo Liu, Keith M Furutani, Jiajian Shen, Martin Bues, Jingjing M Dougherty, Heng Li, Alessio Parisi, Deepak K Shrestha, Sridhar Yaddanpudi, et al.

    Objective. To investigate synchrotron-based proton pencil beam scanning (PBS) beam delivery time (BDT) using novel continuous scanning mode. Approach. A BDT calculation model was developed for the Hitachi particle therapy system. The model was validated against the measured BDT of 36 representative clinical proton PBS plans with discrete spot scanning (DSS) in the current Hitachi proton therapy system. BDTs were calculated with the next generation using Mayo Clinic Florida system operating parameters for conventional DSS, and novel dose driven continuous scanning (DDCS). BDTs of DDCS with and without Break Spots were investigated. Main results. For DDCS without Break Spots, the use of Stop Ratio to control the transit dose largely reduced the beam intensity and consequently, severely prolonged the BDT. DDCS with Break Spots was able to maintain a sufficiently high beam intensity while controlling transit dose. In DDCS with Break Spots, tradeoffs were made between beam intensity and number of Break Spots. Therefore, BDT decreased with increased beam intensity but reached a plateau for beam intensity larger than 10 MU s −1 . Averaging over all clinical plans, BDT was reduced by 10% for DDCS with Break Spots compared to DSS. Significance. DDCS with Break Spots reduced BDT. DDCS has the potential to further reduce BDT under the ideal scenario which requests both stable beam intensity extraction and accurately modelling the transit dose. Further investigation is warranted.


  • Practical Aspects of Particle Therapy Accelerators

    by J. Michele Dougherty, Keith M. Furutani

  • Open Access

    Design of a 3D patient‐specific collision avoidance virtual framework for half‐gantry proton therapy system

    by Jingjing M. Dougherty, Thomas J. Whitaker, Daniel W. Mundy, Erik J. Tryggestad, Chris J. Beltran

    Introduction: This study presents a comprehensive collision avoidance framework based on three‐dimension (3D) computer‐aided design (CAD) modeling, a graphical user interface (GUI) as peripheral to the radiation treatment planning (RTP) environment, and patient‐specific plan parameters for intensity‐modulated proton therapy (IMPT).Methods: A stand‐alone software application was developed leveraging the Varian scripting application programming interface (API) for RTP database object accessibility. The Collision Avoider software models the Hitachi ProBeat‐V half gantry design and the Kuka robotic couch with triangle mesh structures. Patient‐specific plan parameters are displayed in the collision avoidance software for potential proximity evaluation. The external surfaces of the patients and the immobilization devices are contoured based on computed tomography (CT) images. A “table junction‐to‐CT‐origin” (JCT) measurement is made for every patient at the time of CT simulation to accurately provide reference location of the patient contours to the treatment couch. Collision evaluations were performed virtually with the program during treatment planning to prevent four major types of collisional events: collisions between the gantry head and the treatment couch, gantry head and the patient's body, gantry head and the robotic arm, and collisions between the gantry head and the immobilization devices.Results: The Collision Avoider software was able to accurately model the proton treatment delivery system and the robotic couch position. Commonly employed clinical beam configuration and JCT values were investigated. Brain and head and neck patients require more complex gantry and patient positioning system configurations. Physical measurements were performed to validate 3D CAD model geometry. Twelve clinical proton treatment plans were used to validate the accuracy of the software. The software can predict all four types of collisional events in our clinic since its full implementation in 2020.Conclusion: A highly efficient patient‐specific collision prevention program for scanning proton therapy has been successfully implemented. The graphical program has provided accurate collision detection since its inception at our institution.


  • Open Access

    Functional avoidance‐based intensity modulated proton therapy with 4DCT derived ventilation imaging for lung cancer

    by Jingjing M. Dougherty, Edward Castillo, Richard Castillo, Austin M. Faught, Mark Pepin, Sean S. Park, Chris J. Beltran, Thomas Guerrero, Inga Grills, Yevgeniy Vinogradskiy

    The primary objective is to evaluate the potential dosimetric gains of performing functional avoidance-based proton treatment planning using 4DCT derived ventilation imaging. 4DCT data of 31 patients from a prospective functional avoidance clinical trial were evaluated with intensity modulated proton therapy (IMPT) plans and compared with clinical volumetric modulated arc therapy (VMAT) plans. Dosimetric parameters were compared between standard and functional plans with IMPT and VMAT with one-way analysis of variance and post hoc paired student t-test. Normal Tissue Complication Probability (NTCP) models were employed to estimate the risk of two toxicity endpoints for healthy lung tissues. Dose degradation due to proton motion interplay effect was evaluated. Functional IMPT plans led to significant dose reduction to functional lung structures when compared with functional VMAT without significant dose increase to Organ at Risk (OAR) structures. When interplay effect is considered, no significant dose degradation was observed for the OARs or the clinical target volume (CTV) volumes for functional IMPT. Using fV20 as the dose metric and Grade 2+ pneumonitis as toxicity endpoint, there is a mean 5.7% reduction in Grade 2+ RP with the functional IMPT and as high as 26% in reduction for individual patient when compared to the standard IMPT planning. Functional IMPT was able to spare healthy lung tissue to avoid excess dose to normal structures while maintaining satisfying target coverage. NTCP calculation also shows that the risk of pulmonary complications can be further reduced with functional based IMPT.