Monte Carlo Study of Fetal Dosimetry Parameters for 6 MV Photon Beam
Open Access
- 1 January 2013
- journal article
- research article
- Published by Medknow in Journal of Medical Signals & Sensors
- Vol. 3 (1) , 31-6
Abstract
Because of the adverse effects of ionizing radiation on fetuses, prior to radiotherapy of pregnant patients, fetal dose should be estimated. Fetal dose has been studied by several authors in different depths in phantoms with various abdomen thicknesses (ATs). In this study, the effect of maternal AT and depth in fetal dosimetry was investigated, using peripheral dose (PD) distribution evaluations. A BEAMnrc model of Oncor linac using out of beam components was used for dose calculations in out of field border. A 6 MV photon beam was used to irradiate a chest phantom. Measurements were done using EBT2 radiochromic film in a RW3 phantom as abdomen. The followings were measured for different ATs: Depth PD profiles at two distances from the field's edge, and in-plane PD profiles at two depths. The results of this study show that PD is depth dependent near the field's edge. The increase in AT does not change PD depth of maximum and its distribution as a function of distance from the field's edge. It is concluded that estimating the maximum fetal dose, using a flat phantom, i.e., without taking into account the AT, is possible. Furthermore, an in-plane profile measured at any depth can represent the dose variation as a function of distance. However, in order to estimate the maximum PD the depth of Dmax in out of field should be used for in-plane profile measurement.Keywords
This publication has 28 references indexed in Scilit:
- Out-of-field beam characteristics of a 6MV photon beam: Results of a Monte Carlo studyApplied Radiation and Isotopes, 2013
- Internal scatter, the unavoidable major component of the peripheral dose in photon-beam radiotherapyPhysics in Medicine & Biology, 2012
- Experimental study on photon-beam peripheral doses, their components and some possibilities for their reductionPhysics in Medicine & Biology, 2010
- A feasibility study to calculate unshielded fetal doses to pregnant patients in 6-MV photon treatments using Monte Carlo methods and anatomically realistic phantomsMedical Physics, 2008
- A review of dosimetry studies on external-beam radiation treatment with respect to second cancer inductionPhysics in Medicine & Biology, 2008
- Radiotherapy for Glioma During Pregnancy: Fetal Dose Estimates, Risk Assessment and Clinical ManagementClinical Oncology, 2004
- Effect of tertiary multileaf collimator (MLC) on foetal dose during three-dimensional conformal radiation therapy (3DCRT) of a brain tumour during pregnancyRadiotherapy and Oncology, 2004
- Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parametersMedical Physics, 2002
- Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM codeMedical Physics, 2002
- Fetal depth and ultrasound path lengths through overlying tissuesUltrasound in Medicine & Biology, 1989