Maryam Atarod
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Maryam Atarod has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Nadia Najafizade
Department of Radiooncology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
1 shared publicationNahid Shami
Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
1 shared publicationParvaneh Shokrani
Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
1 shared publication- Parvaneh Shokrani
Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
1 shared publication
Latest Publications
- Open Access
- 29 May 2023
- Published by Medknow in Journal of Medical Signals & Sensors
- Vol. 13 (2) , 144-152
Sensitivity Analysis of a 6 MeV Photon Beam Monte Carlo Model
Background: This study aimed to optimize efficiency in Monte Carlo (MC) simulation using sensitivity analysis of a beam model. Methods: The BEAMnrc-based model of 6 MV beam of a Siemens Primus linac was developed. For sensitivity analysis, the effect of the electron source, treatment head, and virtual phantom specifications on calculated percent depth dose (PDD) and lateral dose profiles was evaluated. Results: The optimum mean energy (E) and the full width at half maximum (FWHM) of the intensity distribution of the electron beam were calculated as 6.7 MeV and 3 mm, respectively. Increasing E from 6.1 to 6.7 MeV, increased the PDD in the fall-off region by 4.70% and decreased the lateral profile by 8.76%. Changing the FWHM had a significant effect on the buildup region of PDD and the horns and out-of-field regions of the lateral profile. Increasing the collimators opening by 0.5 mm, PDD increased by 2.13% and the central and penumbra regions of profiles decreased by 1.98% and 11.40% respectively. Collimator properties such as thickness and density were effective in changing the penumbra (11.32% for 0.25 cm increment) and the out-of-field (22.82% for 3 g/cm3) regions of the lateral profiles. Conclusion: Analysis of a 6 MV model showed that PDD profiles were more sensitive to changes in energy than to FWHM of the electron source. The lateral profiles were sensitive to E, FWHM, and collimator opening. The density of the collimator affected only the out-of-field region of lateral profiles. The findings of this study may be used to make benchmarking of an MC beam model more efficient.
- 29 May 2023
- Published by Medknow in Journal of Medical Signals & Sensors
- Vol. 13 (2) , 144-152
Open AccessSensitivity Analysis of a 6 MeV Photon Beam Monte Carlo Model
Background: This study aimed to optimize efficiency in Monte Carlo (MC) simulation using sensitivity analysis of a beam model. Methods: The BEAMnrc-based model of 6 MV beam of a Siemens Primus linac was developed. For sensitivity analysis, the effect of the electron source, treatment head, and virtual phantom specifications on calculated percent depth dose (PDD) and lateral dose profiles was evaluated. Results: The optimum mean energy (E) and the full width at half maximum (FWHM) of the intensity distribution of the electron beam were calculated as 6.7 MeV and 3 mm, respectively. Increasing E from 6.1 to 6.7 MeV, increased the PDD in the fall-off region by 4.70% and decreased the lateral profile by 8.76%. Changing the FWHM had a significant effect on the buildup region of PDD and the horns and out-of-field regions of the lateral profile. Increasing the collimators opening by 0.5 mm, PDD increased by 2.13% and the central and penumbra regions of profiles decreased by 1.98% and 11.40% respectively. Collimator properties such as thickness and density were effective in changing the penumbra (11.32% for 0.25 cm increment) and the out-of-field (22.82% for 3 g/cm3) regions of the lateral profiles. Conclusion: Analysis of a 6 MV model showed that PDD profiles were more sensitive to changes in energy than to FWHM of the electron source. The lateral profiles were sensitive to E, FWHM, and collimator opening. The density of the collimator affected only the out-of-field region of lateral profiles. The findings of this study may be used to make benchmarking of an MC beam model more efficient.
- Open Access
- 1 January 2013
- Published by Medknow in Journal of Medical Signals & Sensors
- Vol. 3 (1) , 31-6
Monte Carlo Study of Fetal Dosimetry Parameters for 6 MV Photon Beam
Because of the adverse effects of ionizing radiation on fetuses, prior to radiotherapy of pregnant patients, fetal dose should be estimated. Fetal dose has been studied by several authors in different depths in phantoms with various abdomen thicknesses (ATs). In this study, the effect of maternal AT and depth in fetal dosimetry was investigated, using peripheral dose (PD) distribution evaluations. A BEAMnrc model of Oncor linac using out of beam components was used for dose calculations in out of field border. A 6 MV photon beam was used to irradiate a chest phantom. Measurements were done using EBT2 radiochromic film in a RW3 phantom as abdomen. The followings were measured for different ATs: Depth PD profiles at two distances from the field's edge, and in-plane PD profiles at two depths. The results of this study show that PD is depth dependent near the field's edge. The increase in AT does not change PD depth of maximum and its distribution as a function of distance from the field's edge. It is concluded that estimating the maximum fetal dose, using a flat phantom, i.e., without taking into account the AT, is possible. Furthermore, an in-plane profile measured at any depth can represent the dose variation as a function of distance. However, in order to estimate the maximum PD the depth of Dmax in out of field should be used for in-plane profile measurement.
- 1 January 2013
- Published by Medknow in Journal of Medical Signals & Sensors
- Vol. 3 (1) , 31-6
Open AccessMonte Carlo Study of Fetal Dosimetry Parameters for 6 MV Photon Beam
Because of the adverse effects of ionizing radiation on fetuses, prior to radiotherapy of pregnant patients, fetal dose should be estimated. Fetal dose has been studied by several authors in different depths in phantoms with various abdomen thicknesses (ATs). In this study, the effect of maternal AT and depth in fetal dosimetry was investigated, using peripheral dose (PD) distribution evaluations. A BEAMnrc model of Oncor linac using out of beam components was used for dose calculations in out of field border. A 6 MV photon beam was used to irradiate a chest phantom. Measurements were done using EBT2 radiochromic film in a RW3 phantom as abdomen. The followings were measured for different ATs: Depth PD profiles at two distances from the field's edge, and in-plane PD profiles at two depths. The results of this study show that PD is depth dependent near the field's edge. The increase in AT does not change PD depth of maximum and its distribution as a function of distance from the field's edge. It is concluded that estimating the maximum fetal dose, using a flat phantom, i.e., without taking into account the AT, is possible. Furthermore, an in-plane profile measured at any depth can represent the dose variation as a function of distance. However, in order to estimate the maximum PD the depth of Dmax in out of field should be used for in-plane profile measurement.