Abstract
Background and purpose — Guidelines for standardization of radiostereometry (RSA) of implants were published in 2005 to facilitate comparison of outcomes between various research groups. In this systematic review, we determined how well studies have adhered to these guidelines. Methods — We carried out a literature search to identify all articles published between January 2000 and December 2011 that used RSA in the evaluation of hip or knee prosthesis migration. 2 investigators independently evaluated each of the studies for adherence to the 13 individual guideline items. Since some of the 13 points included more than 1 criterion, studies were assessed on whether each point was fully met, partially met, or not met. Results — 153 studies that met our inclusion criteria were identified. 61 of these were published before the guidelines were introduced (2000–2005) and 92 after the guidelines were introduced (2006–2011). The methodological quality of RSA studies clearly improved from 2000 to 2011. None of the studies fully met all 13 guidelines. Nearly half (43) of the studies published after the guidelines demonstrated a high methodological quality and adhered at least partially to 10 of the 13 guidelines, whereas less than one-fifth (11) of the studies published before the guidelines had the same methodological quality. Commonly unaddressed guideline items were related to imaging methodology, determination of precision from double examinations, and also mean error of rigid-body fitting and condition number cutoff levels. Interpretation — The guidelines have improved methodological reporting in RSA studies, but adherence to these guidelines is still relatively low. There is a need to update and clarify the guidelines for clinical hip and knee arthroplasty RSA studies.Keywords
This publication has 164 references indexed in Scilit:
- The effects of different weight-bearing regimes on press-fit cup stability: a randomised study with five years of follow-up using radiostereometryInternational Orthopaedics, 2011
- Less wear with aluminium-oxide heads than cobalt-chrome heads with ultra high molecular weight cemented polyethylene cups: A ten-year follow-up with radiostereometryInternational Orthopaedics, 2011
- A prospective randomised radiostereometric analysis trial of SmartSet HV and Palacos R bone cements in primary total hip arthroplastyJournal of Orthopaedics and Traumatology, 2010
- Two-year migration results of the ReCap hip resurfacing system—a radiostereometric follow-up study of 23 hipsInternational Orthopaedics, 2010
- Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA studyInternational Orthopaedics, 2009
- Celecoxib does not appear to affect prosthesis fixation in total knee replacementActa Orthopaedica, 2009
- Computer assisted versus conventional cemented total knee prostheses alignment accuracy and micromotion of the tibial componentInternational Orthopaedics, 2008
- Comparison of cementing techniques of the tibial component in total knee replacementInternational Orthopaedics, 2008
- Effect of bioactive coating of the tibial component on migration pattern in uncemented total knee arthroplasty: a randomized RSA study of 14 knees presented according to new RSA-guidelinesJournal of Orthopaedics and Traumatology, 2008
- Guidelines for standardization of radiostereometry (RSA) of implantsActa Orthopaedica, 2005