Rami Madanat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rami Madanat has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Tatu Mäkinen
2 shared publicationsCharles Bragdon
Harris Orthopaedic Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
1 shared publication- Hannu T. Aro
Department of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku, Finland
1 shared publication Henrik Malchau
Harris Orthopaedic Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
1 shared publicationJan Lindahl
1 shared publicationJarkko Pajarinen
1 shared publication
Latest Publications
- 1 January 2015
- Vol. 131 (16) , 1451-9
[Complications in ankle fracture surgery].
Ankle fractures are among the most frequently encountered surgically treated fractures. The operative treatment can be associated with several complications such as malreduction and infection. Reinforcing the surgical armamentarium with meticulous preoperative planning together with recognition of common surgical errors are valuable adjuncts in reducing these complications. Furthermore, it is crucial to recognize and address modifiable risk factors for infection so as to minimize this potentially devastating complication. When a deep infection does occur, it is best managed by a multidisciplinary musculosceletal infection team.
- 1 January 2015
- Vol. 131 (16) , 1451-9
[Complications in ankle fracture surgery].
Ankle fractures are among the most frequently encountered surgically treated fractures. The operative treatment can be associated with several complications such as malreduction and infection. Reinforcing the surgical armamentarium with meticulous preoperative planning together with recognition of common surgical errors are valuable adjuncts in reducing these complications. Furthermore, it is crucial to recognize and address modifiable risk factors for infection so as to minimize this potentially devastating complication. When a deep infection does occur, it is best managed by a multidisciplinary musculosceletal infection team.
- Open Access
- 23 June 2014
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 85 (5) , 447-455
Adherence of hip and knee arthroplasty studies to RSA standardization guidelines
Background and purpose — Guidelines for standardization of radiostereometry (RSA) of implants were published in 2005 to facilitate comparison of outcomes between various research groups. In this systematic review, we determined how well studies have adhered to these guidelines. Methods — We carried out a literature search to identify all articles published between January 2000 and December 2011 that used RSA in the evaluation of hip or knee prosthesis migration. 2 investigators independently evaluated each of the studies for adherence to the 13 individual guideline items. Since some of the 13 points included more than 1 criterion, studies were assessed on whether each point was fully met, partially met, or not met. Results — 153 studies that met our inclusion criteria were identified. 61 of these were published before the guidelines were introduced (2000–2005) and 92 after the guidelines were introduced (2006–2011). The methodological quality of RSA studies clearly improved from 2000 to 2011. None of the studies fully met all 13 guidelines. Nearly half (43) of the studies published after the guidelines demonstrated a high methodological quality and adhered at least partially to 10 of the 13 guidelines, whereas less than one-fifth (11) of the studies published before the guidelines had the same methodological quality. Commonly unaddressed guideline items were related to imaging methodology, determination of precision from double examinations, and also mean error of rigid-body fitting and condition number cutoff levels. Interpretation — The guidelines have improved methodological reporting in RSA studies, but adherence to these guidelines is still relatively low. There is a need to update and clarify the guidelines for clinical hip and knee arthroplasty RSA studies.
- 23 June 2014
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 85 (5) , 447-455
Open AccessAdherence of hip and knee arthroplasty studies to RSA standardization guidelines
Background and purpose — Guidelines for standardization of radiostereometry (RSA) of implants were published in 2005 to facilitate comparison of outcomes between various research groups. In this systematic review, we determined how well studies have adhered to these guidelines. Methods — We carried out a literature search to identify all articles published between January 2000 and December 2011 that used RSA in the evaluation of hip or knee prosthesis migration. 2 investigators independently evaluated each of the studies for adherence to the 13 individual guideline items. Since some of the 13 points included more than 1 criterion, studies were assessed on whether each point was fully met, partially met, or not met. Results — 153 studies that met our inclusion criteria were identified. 61 of these were published before the guidelines were introduced (2000–2005) and 92 after the guidelines were introduced (2006–2011). The methodological quality of RSA studies clearly improved from 2000 to 2011. None of the studies fully met all 13 guidelines. Nearly half (43) of the studies published after the guidelines demonstrated a high methodological quality and adhered at least partially to 10 of the 13 guidelines, whereas less than one-fifth (11) of the studies published before the guidelines had the same methodological quality. Commonly unaddressed guideline items were related to imaging methodology, determination of precision from double examinations, and also mean error of rigid-body fitting and condition number cutoff levels. Interpretation — The guidelines have improved methodological reporting in RSA studies, but adherence to these guidelines is still relatively low. There is a need to update and clarify the guidelines for clinical hip and knee arthroplasty RSA studies.
- 1 January 2013
- Vol. 129 (11) , 1186-91
[Posterior dislocation of the sternoclavicular joint].
Posterior dislocation of the sternoclavicular joint is a rare injury. It can be associated with life-threatening complications. Computed tomography is the imaging modality of choice with which possible associated injuries can be detected. Acute injuries are managed with closed reduction under general anaesthesia. A fracture-dislocation is inherently more unstable than an isolated dislocation. Surgical treatment is advocated in cases of delayed diagnosis or failed closed reduction. With early diagnosis and treatment, the long-term outcome of this injury is good.
- 1 January 2013
- Vol. 129 (11) , 1186-91
[Posterior dislocation of the sternoclavicular joint].
Posterior dislocation of the sternoclavicular joint is a rare injury. It can be associated with life-threatening complications. Computed tomography is the imaging modality of choice with which possible associated injuries can be detected. Acute injuries are managed with closed reduction under general anaesthesia. A fracture-dislocation is inherently more unstable than an isolated dislocation. Surgical treatment is advocated in cases of delayed diagnosis or failed closed reduction. With early diagnosis and treatment, the long-term outcome of this injury is good.
- 1 July 2011
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 16 (4) , 467-470
Simultaneous bilateral subtrochanteric fractures following risedronate therapy
- 1 July 2011
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 16 (4) , 467-470
Simultaneous bilateral subtrochanteric fractures following risedronate therapy