Rupture threshold characterization of polymer-shelled ultrasound contrast agents subjected to static overpressure
- 15 April 2011
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 109 (8) , 084906-084906-10
Abstract
Polymer-shelled micro-bubbles are employed as ultrasound contrast agents (UCAs) and vesicles for targeted drug delivery. UCA-based delivery of the therapeutic payload relies on ultrasound-induced shell rupture. The fragility of two polymer-shelled UCAs manufactured by Point Biomedical or Philips Research was investigated by characterizing their response to static overpressure. The nominal diameters of Point and Philips UCAs were 3 μm and 2 μm, respectively. The UCAs were subjected to static overpressure in a glycerol-filled test chamber with a microscope-reticule lid. UCAs were reconstituted in 0.1 mL of water and added over the glycerol surface in contact with the reticule. A video-microscope imaged UCAs as glycerol was injected (5 mL/h) to vary the pressure from 2 to 180 kPa over 1 h. Neither UCA population responded to overpressure until the rupture threshold was exceeded, which resulted in abrupt destruction. The rupture data for both UCAs indicated three subclasses that exhibited different rupture behavior, although their mean diameters were not statistically different. The rupture pressures provided a measure of UCA fragility; the Philips UCAs were more resilient than Point UCAs. Results were compared to theoretical models of spherical shells under compression. Observed variations in rupture pressures are attributed to shell imperfections. These results may provide means to optimize polymeric UCAs for drug delivery and elucidate associated mechanisms.Keywords
This publication has 51 references indexed in Scilit:
- Focused ultrasound and microbubbles for enhanced extravasationJournal of Controlled Release, 2010
- Buckling of empty spherical viruses under external pressureJournal of Applied Physics, 2009
- Subharmonic analysis using singular-value decomposition of ultrasound contrast agentsThe Journal of the Acoustical Society of America, 2009
- Effect of Molecular Weight, Crystallinity, and Hydrophobicity on the Acoustic Activation of Polymer-Shelled Ultrasound Contrast AgentsBiomacromolecules, 2009
- Ultrasound contrast microbubbles in imaging and therapy: physical principles and engineeringPhysics in Medicine & Biology, 2009
- Preparation of monodisperse polymer particles and capsules by ink-jet printingColloids and Surfaces A: Physicochemical and Engineering Aspects, 2006
- Ultrasound Contrast Agents for Brain Perfusion Imaging and Ischemic Stroke TherapyJournal of Neuroimaging, 2005
- Buckling of a spherical shell embedded in an elastic medium loaded by a far-field hydrostatic pressureThe Journal of Strain Analysis for Engineering Design, 2001
- Comparative study of Hough Transform methods for circle findingImage and Vision Computing, 1990
- On the accuracy of the Sobel edge detectorImage and Vision Computing, 1983