  • Quantitative photoacoustic assessment of ex-vivo lymph nodes of colorectal cancer patients

    by Ashwin Sampathkumar, Jonathan Mamou, Emi Saegusa-Beercroft, Parag V. Chitnis, Junji Machi, Ernest J. Feleppa

    Staging of cancers and selection of appropriate treatment requires histological examination of multiple dissected lymph nodes (LNs) per patient, so that a staggering number of nodes require histopathological examination, and the finite resources of pathology facilities create a severe processing bottleneck. Histologically examining the entire 3D volume of every dissected node is not feasible, and therefore, only the central region of each node is examined histologically, which results in severe sampling limitations. In this work, we assess the feasibility of using quantitative photoacoustics (QPA) to overcome the limitations imposed by current procedures and eliminate the resulting under sampling in node assessments. QPA is emerging as a new hybrid modality that assesses tissue properties and classifies tissue type based on multiple estimates derived from spectrum analysis of photoacoustic (PA) radiofrequency (RF) data and from statistical analysis of envelope-signal data derived from the RF signals. Our study seeks to use QPA to distinguish cancerous from non-cancerous regions of dissected LNs and hence serve as a reliable means of imaging and detecting small but clinically significant cancerous foci that would be missed by current methods. Dissected lymph nodes were placed in a water bath and PA signals were generated using a wavelength-tunable (680-950 nm) laser. A 26-MHz, f-2 transducer was used to sense the PA signals. We present an overview of our experimental setup; provide a statistical analysis of multi-wavelength classification parameters (mid-band fit, slope, intercept) obtained from the PA signal spectrum generated in the LNs; and compare QPA performance with our established quantitative ultrasound (QUS) techniques in distinguishing metastatic from non-cancerous tissue in dissected LNs. QPA-QUS methods offer a novel general means of tissue typing and evaluation in a broad range of disease-assessment applications, e.g., cardiac, intravascular, musculoskeletal, endocrine-gland, etc.

  • Spectrum analysis of photoacoustic signals for tissue classification

    by Parag V. Chitnis, Jonathan Mamou, Ashwin Sampathkumar, Ernest J. Feleppa

    Quantitative ultrasound (QUS) estimates derived from power spectra of pulse-echo signals are sensitive to mi- crostructure and potentially can differentiate among tissues. However, QUS estimates do not provide molecular specificity. We investigated the feasibility of obtaining quantitative photoacoustic (QPA) estimates for sensi- tivity to microstructure and chromophores for tissue classification. QPA methods were tested using gel-based phantoms containing uniformly dispersed, black polyethylene spheres (1E5 particles/ml) with nominal mean diameters of 23.5, 29.5, 42.0, and 58.0 μm. A pulsed, 532-nm laser excited the photoacoustic (PA) response. A single-element, 34-MHz transducer with a 12-mm focal length was raster scanned over the phantom to acquire 3D PA data. Normalized power spectra were generated from the PA signals within 2079, moving (50% overlap), 1-mm-cube regions-of-interest (ROIs) to provide three QPA estimates: spectral slope (SS), spectral intercept (SI), and effective absorber size (EAS). SS and SI were computed using a linear-regression approximation to the normalized spectrum in the -6-dB band. EAS was computed by fitting the normalized spectrum in the -20-dB band to the multi-sphere analytical solution. All estimates were correlated with the size of particles dispersed in the phantoms. SS decreased while SI increased with an increase in particle size. EAS was correlated with nominal particle diameter, but particles aggregation and the finite bandwidth of the PAI system resulted in outliers. SS, SI, and EAS for the 23.5-μm-phantom were -0.14±-0.04 dB/MHz, 4.8±1.3 dB, and 25.4±6.3 μm, respectively; the corresponding values for the 58.0-μm phantom were -0.47±-0.03 dB/MHz, 15.6±0.9 dB, and 82.7±0.9 μm.


  • Shell material parameter measurements of polymer ultrasound contrast agents

    by Pavlos Anastasiadis, John S. Allen, Parag V. Chitnis, Jeffrey A. Ketterling

  • Rupture threshold characterization of polymer-shelled ultrasound contrast agents subjected to static overpressure

    by Parag V. Chitnis, Paul Lee, Jonathan Mamou, John S. Allen, Marcel Böhmer, Jeffrey A. Ketterling

    Polymer-shelled micro-bubbles are employed as ultrasound contrast agents (UCAs) and vesicles for targeted drug delivery. UCA-based delivery of the therapeutic payload relies on ultrasound-induced shell rupture. The fragility of two polymer-shelled UCAs manufactured by Point Biomedical or Philips Research was investigated by characterizing their response to static overpressure. The nominal diameters of Point and Philips UCAs were 3 μm and 2 μm, respectively. The UCAs were subjected to static overpressure in a glycerol-filled test chamber with a microscope-reticule lid. UCAs were reconstituted in 0.1 mL of water and added over the glycerol surface in contact with the reticule. A video-microscope imaged UCAs as glycerol was injected (5 mL/h) to vary the pressure from 2 to 180 kPa over 1 h. Neither UCA population responded to overpressure until the rupture threshold was exceeded, which resulted in abrupt destruction. The rupture data for both UCAs indicated three subclasses that exhibited different rupture behavior, although their mean diameters were not statistically different. The rupture pressures provided a measure of UCA fragility; the Philips UCAs were more resilient than Point UCAs. Results were compared to theoretical models of spherical shells under compression. Observed variations in rupture pressures are attributed to shell imperfections. These results may provide means to optimize polymeric UCAs for drug delivery and elucidate associated mechanisms.


  • Simultaneous high-frequency ultrasound and optoacoustic imaging of in vivo mouse embryos.

    by Parag V. Chitnis, Orlando Aristizábal, Jonathan Mamou, Daniel H. Turnbull, Jeffrey A. Ketterling

  • Response of polymer-shelled ultrasound contrast agents to static overpressure.

    by Parag V. Chitnis, Paul Lee, Jonathan Mamou, John S. Allen, Jeffrey A. Ketterling

    The static‐pressure threshold for rupturing polymer‐shelled ultrasound contrast agents (UCAs) manufactured by POINT Biomedical (mean diameter 3 μm, shell‐thickness‐to‐radius ratio (STRR) 7.5 nm/μm, count 961) and Philips Research (mean diameter 2 μm, STRR 40 nm/μm, count 1048) was investigated. The UCAs were subjected to static overpressure in a glycerol‐filled test chamber with a microscope reticule lid at the top. UCAs were reconstituted in 0.1 ml of water and added on top of the glycerol surface in contact with the reticule. A video‐microscope captured UCA images while glycerol was introduced at 5 ml/h, resulting in overpressure ranging from 2–180 kPa. UCAs were sized using semi‐automated post‐processing algorithm. The static pressure corresponding to each frame was recorded. Neither UCA population responded to static pressure until the rupture threshold was exceeded, which resulted in an abrupt destruction. The rupture pressure of both UCAs was uncorrelated to diameter. A k‐means algorithm divided the pressure data for both UCA populations into three groups: primary, residual, and intact. The three groups exhibited different rupture behaviors although their mean diameters were not statistically different. The results indicated that the Philips UCAs were three‐times more resilient to rupture than the Point UCAs. [Work supported by NIH EB006372.]

  • Mitigation of Damage to Solid Surfaces From the Collapse of Cavitation Bubble Clouds

    by Parag V. Chitnis, Nicholas J. Manzi, Robin O. Cleveland, Ronald A. Roy, R. Glynn Holt

    The collapse of transient bubble clouds near a solid surface was investigated to test a scheme for mitigation of cavitation-induced damage. The target was a porous ceramic disk through which air could be forced. Transient cavitation bubbles were created using a shock-wave lithotripter focused on the surface of the disk. The dynamics of bubble clouds near the ceramic disks were studied for two boundary conditions: no back pressure resulting in surface free of bubbles and 10 psi (0.7 atm) of back pressure, resulting in a surface with a sparse (30% of area) bubble layer. Images of the cavitation near the surface were obtained from a high-speed camera. Additionally, a passive cavitation detector (3.5 MHz focused acoustic transducer) was aligned with the surface. Both the images and the acoustic measurements indicated that bubble clouds near a ceramic face without a bubble layer collapsed onto the boundary, subsequently leading to surface erosion. When a sparse bubble layer was introduced, bubble clouds collapsed away from the surface, thus mitigating cavitation damage. The erosion damage to the ceramic disks after 300 shock waves was quantified using micro-CT imaging. Pitting up to 1 mm deep was measured for the bubble-free surface, and the damage to the bubble surface was too small to be detected.


  • Response of ultrasound contrast agents to static overpressure.

    by Parag V. Chitnis, Paul Lee, Jonathan Mamou, Jeffrey A. Ketterling

  • Resonant bubble effects in void fraction measurements from modal frequencies of a bubbly impedance tube

    by Christopher E. Ormonde, Seth B. Cohen, Parag V. Chitnis, Robin O. Cleveland, Ronald A. Roy, R. Glynn Holt

    The effects of resonantbubbles on the measurement of void fraction in a cylindrical waveguide are examined. Air bubbles are introduced into a steel cylindrical waveguide containing a Xanthan gum gel. The frequency response of the system is obtained. Sound speeds are inferred by assuming a linear dependence of axial mode number on mode frequency, and void fractions are calculated assuming a mixture sound speed for a bubble population much smaller than the resonant sizes in the modal frequency range (Woods limit). Results from experiments with various bubble sizes and varying number of bubbles are presented, including single bubbles, two differently sized bubbles, and multiple bubbles of roughly the same size. Local dispersion effects are exhibited in the region of bubble resonance for bubbles that are large enough to violate the Woods limit assumption. The effect of such rogue bubbles on the accuracy of the void fraction measurement in a system with unknown bubble size is considered. [Work supported by ORNL.]