Long-Term Outcomes Following Cochlear Implantation: Device “Aging” and Hearing Performance
Open Access
- 24 February 2025
- journal article
- research article
- Published by MDPI AG in Audiology Research
- Vol. 15 (2) , 19
Abstract
Purpose: The purpose of this study was to evaluate the clinical and audiological outcomes in long-term cochlear implant (CI) users, focusing on hearing performance and device failures. Methods: A retrospective study was conducted on patients who underwent CI surgery, with a minimum follow-up of 10 years. Device survival was analyzed using Kaplan–Meier curves, and failure rates were classified as device failure explants or medical-related explants. The time to revision and causes of reimplantation were assessed. Statistical analyses included Pearson correlation for audiological outcomes, Student’s t-test for group comparisons, and the log-rank test for survival comparisons among implant brands. Results: In this study, data from a total of 211 CIs were collected. Fourteen major postoperative complications were reported in this series, resulting in a global major complication rate of 6.6%: 5.2% due to hard failure and 1.4% due to medical problems and soft failure. The revision rate was 4.1% for the children’s group and 10% for the adult group. The overall device survival rates were more than 96% at 10 years and 91% at 20 years. The median postoperative follow-up was 16.3 years. Moreover, a highly significant correlation was observed (r = 0.669, p < 0.0001) between pure tone average (PTA) thresholds at implant activation and those at the last follow-up, as analyzed using Pearson’s correlation coefficient. Conclusions: The CI is a lifelong device; however, the technology is constantly evolving. Therefore, careful patient counseling (or counseling of parents in the case of pediatric patients) is necessary. The device may wear out over time, requiring revision surgery. These data are essential for audiologists and ENT specialists when selecting patients and determining surgical indications.Keywords
This publication has 29 references indexed in Scilit:
- Revision Cochlear Implantation With Device Manufacturer Conversion: Surgical Outcomes and Speech Perception PerformanceOtolaryngology–Head and Neck Surgery, 2024
- Frequency reallocation based on cochlear place frequencies in cochlear implants: a pilot studyEuropean Archives of Oto-Rhino-Laryngology, 2022
- A retrospective review of cochlear implant revision surgery: a 24-year experience in ChinaEuropean Archives of Oto-Rhino-Laryngology, 2021
- Analysis of cochlear implant revision surgeriesEuropean Archives of Oto-Rhino-Laryngology, 2020
- Evaluating Reasons for Revision Surgery and Device Failure Rates in Patients Who Underwent Cochlear Implantation SurgeryJAMA Otolaryngology–Head & Neck Surgery, 2020
- Cochlear implant failures and reimplantation: A 30‐year analysis and literature reviewThe Laryngoscope, 2019
- Surgical findings and auditory performance after cochlear implant revision surgeryEuropean Archives of Oto-Rhino-Laryngology, 2015
- Rates of revision and device failure in cochlear implant surgery: A 30‐year experienceThe Laryngoscope, 2014
- Revision surgeries in cochlear implant patients: a review of 45 casesEuropean Archives of Oto-Rhino-Laryngology, 2006
- Cochlear Implant ComplicationsJAMA Otolaryngology–Head & Neck Surgery, 2005