Riccardo Nocini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Riccardo Nocini has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Daniele Monzani
ENT and Audiology Department, University Hospital of Verona, 37126 Verona, Italy
1 shared publication - Davide Soloperto
Audiology Program, Otorhinolaryngology Unit, Department of Medical and Surgical Sciences for Children and Adults, University of Modena and Reggio Emilia, 41124 Modena, Italy
1 shared publication - Gennaro Confuorto
Department of Otorhinolaryngology, Sassuolo Hospital, 41049 Modena, Italy
1 shared publication - Luca Sacchetto
Otolaryngology-Head and Neck Surgery Department, University of Verona, 37129 Verona, Italy
1 shared publication - Marco Carner
Unit of Otorhinolaryngology, Head & Neck Department, University of Verona, 37134 Verona, Italy
1 shared publication - Virginia Dallari
Department of Otolaryngology Head and Neck Surgery, Santa Maria delle Croci Hospital, AUSL della Romagna, 48121 Ravenna, Italy
1 shared publication
Latest Publications
- Open Access
- 24 February 2025
- Published by MDPI AG in Audiology Research
- Vol. 15 (2) , 19
Long-Term Outcomes Following Cochlear Implantation: Device “Aging” and Hearing Performance
Purpose: The purpose of this study was to evaluate the clinical and audiological outcomes in long-term cochlear implant (CI) users, focusing on hearing performance and device failures. Methods: A retrospective study was conducted on patients who underwent CI surgery, with a minimum follow-up of 10 years. Device survival was analyzed using Kaplan–Meier curves, and failure rates were classified as device failure explants or medical-related explants. The time to revision and causes of reimplantation were assessed. Statistical analyses included Pearson correlation for audiological outcomes, Student’s t-test for group comparisons, and the log-rank test for survival comparisons among implant brands. Results: In this study, data from a total of 211 CIs were collected. Fourteen major postoperative complications were reported in this series, resulting in a global major complication rate of 6.6%: 5.2% due to hard failure and 1.4% due to medical problems and soft failure. The revision rate was 4.1% for the children’s group and 10% for the adult group. The overall device survival rates were more than 96% at 10 years and 91% at 20 years. The median postoperative follow-up was 16.3 years. Moreover, a highly significant correlation was observed (r = 0.669, p < 0.0001) between pure tone average (PTA) thresholds at implant activation and those at the last follow-up, as analyzed using Pearson’s correlation coefficient. Conclusions: The CI is a lifelong device; however, the technology is constantly evolving. Therefore, careful patient counseling (or counseling of parents in the case of pediatric patients) is necessary. The device may wear out over time, requiring revision surgery. These data are essential for audiologists and ENT specialists when selecting patients and determining surgical indications.
- 24 February 2025
- Published by MDPI AG in Audiology Research
- Vol. 15 (2) , 19
Open AccessLong-Term Outcomes Following Cochlear Implantation: Device “Aging” and Hearing Performance
Purpose: The purpose of this study was to evaluate the clinical and audiological outcomes in long-term cochlear implant (CI) users, focusing on hearing performance and device failures. Methods: A retrospective study was conducted on patients who underwent CI surgery, with a minimum follow-up of 10 years. Device survival was analyzed using Kaplan–Meier curves, and failure rates were classified as device failure explants or medical-related explants. The time to revision and causes of reimplantation were assessed. Statistical analyses included Pearson correlation for audiological outcomes, Student’s t-test for group comparisons, and the log-rank test for survival comparisons among implant brands. Results: In this study, data from a total of 211 CIs were collected. Fourteen major postoperative complications were reported in this series, resulting in a global major complication rate of 6.6%: 5.2% due to hard failure and 1.4% due to medical problems and soft failure. The revision rate was 4.1% for the children’s group and 10% for the adult group. The overall device survival rates were more than 96% at 10 years and 91% at 20 years. The median postoperative follow-up was 16.3 years. Moreover, a highly significant correlation was observed (r = 0.669, p < 0.0001) between pure tone average (PTA) thresholds at implant activation and those at the last follow-up, as analyzed using Pearson’s correlation coefficient. Conclusions: The CI is a lifelong device; however, the technology is constantly evolving. Therefore, careful patient counseling (or counseling of parents in the case of pediatric patients) is necessary. The device may wear out over time, requiring revision surgery. These data are essential for audiologists and ENT specialists when selecting patients and determining surgical indications.