An Anatomic Study to Determine the Optimal Entry Point, Medial Angles, and Effective Length for Safe Fixation Using Posterior C1 Lateral Mass Screws
Authors:
- Yong HuYHYong Hu
- Wei-Xin DongWDWei-Xin Dong
- William Ryan SpikerWSWilliam Ryan Spiker
- Zhen-Shan YuanZYZhen-Shan Yuan
- Xiao-Yang SunXSXiao-Yang Sun
- Jiao ZhangJZJiao Zhang
- Hui XieHXHui Xie
- Todd J. AlbertTATodd J. Albert
- 15 February 2015
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 40 (4) , E191-E198
Abstract
Study Design. Anatomic study of the C1 lateral mass using fine-cut computed tomographic scans and Mimics software. Objective. To investigate the optimal entry point, medial angles, and effective length for safe fixation using posterior C1 lateral mass screws. Summary of Background Data. Placing posterior C1 lateral mass screws is technically demanding, and a misplaced screw can result in injury to the vertebral artery, spinal cord, or internal carotid artery. Although various insertion angles have been proposed for posterior C1 lateral mass screw, no clear consensus has been reached on the ideal medial angle of the C1 lateral mass. Methods. The C1 lateral masses were evaluated using computed tomographic scans and Mimics software in 70 patients. The effective width and effective screw length of posterior C1 lateral mass screws were measured at different medial angulations relative to the midline sagittal plane. The height (H) for screw entry point on the posterior surface of C1 lateral mass and the distance (D) between screw entry point and the intersection of the midline sagittal plane and the posterior arch of the atlas were also measured. Results. The mean height (H) for screw entry on the posterior surface of the lateral mass was 4.25 mm, the mean distance (D) between screw entry point and the intersection of the midsagittal plane and the posterior arch of the atlas was 27.62 mm. The optimal medial angle was 20.86° with a corresponding effective width of 10.56 mm and effective screw length of 21.87 mm. Conclusion. This study helps to define the specific anatomy related to C1 posterior lateral mass screw placement in an effort to facilitate instrumentation. However, variation is seen in lateral mass anatomy, and this study must be combined with customized surgical planning that includes advanced imaging for safe and effective instrumentation. Level of Evidence: 1Keywords
This publication has 21 references indexed in Scilit:
- Deviation Analysis of C1–C2 Transarticular Screw Placement Assisted by a Novel Rapid Prototyping Drill TemplateJournal of Spinal Disorders & Techniques, 2014
- Clinical outcome of posterior fixation of the C1 lateral mass and C2 pedicle by polyaxial screw and rodClinical Neurology and Neurosurgery, 2012
- Clinical and radiological Comparison of treatment of atlantoaxial instability by posterior C1–C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixationJournal of Clinical Neuroscience, 2010
- The Feasibility of Microscope-Assisted “Free-Hand” C1 Lateral Mass Screw Insertion Without FluoroscopySpine, 2008
- Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniquesJournal of Neurosurgery: Spine, 2008
- The Use of C1 Lateral Mass Screws in Complex Cervical Spine Surgery: Indications, Techniques, and Outcome in a Prospective Consecutive Series of 25 CasesJournal of Spinal Disorders & Techniques, 2007
- Atlantoaxial fixation using the polyaxial screw–rod systemEuropean Spine Journal, 2006
- Atlantoaxial Fixation Using Plate and Screw Method: A Report of 160 Treated PatientsNeurosurgery, 2002
- Posterior C1–C2 Fusion With Polyaxial Screw and Rod FixationSpine, 2001
- Plate and screw fixation for atlanto-axial subluxationActa Neurochirurgica, 1994