Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement
Open Access
Abstract
Air-coupled ultrasonic probes require a special design approach and handling due to the significant mismatch to the air. Outer matching layers have to be soft so can be easily damaged and excitation voltages might cause the degradation of electrodes or bonding between the layers. Integrity inspection is desired during design, manufacturing, and exploitation. Spatial distribution of a transduction efficiency over piezoelement surface is proposed as a convenient means for the air-coupled probe integrity inspection. Focused transducer of similar center frequency is used to scan the surface of the inspected probe. However, such approach creates a challenge, i.e., area of the scanning beam is much smaller than the total receiving area of the inspected probe, therefore, contrast and imaging resolution are significantly degraded. Masking aperture made from cardboard and felt, placed at the focal point was proposed as solution. Far-range sidelobes were suppressed down to the noise floor (−50 dB) and the near-range sidelobes were reduced down to −17 dB. The proposed modification allows to use a similar frequency focused transducer. Probe integrity inspection can be carried out at significantly enhanced contrast and lateral resolution. Natural and artificial defects can be detected by the use of the proposed method.Keywords
Funding Information
- European Regional Development Fund (01.2.2-LMT-K-718-03-0026)
This publication has 35 references indexed in Scilit:
- Non-contact ultrasonic technique for Lamb wave characterization in composite platesUltrasonics, 2016
- Half bridge topology 500 V pulser for ultrasonic transducer excitationUltrasonics, 2015
- Electronics for Ultrasonic Imaging SystemElektronika ir Elektrotechnika, 2014
- Review of air-coupled ultrasonic materials characterizationUltrasonics, 2014
- Air-Coupled Piezoelectric Transducers with Active Polypropylene Foam Matching LayersSensors, 2013
- Enhanced electromechanical response of ferroelectret ultrasonic transducers under high voltage excitationAdvances in Applied Ceramics: Structural, Functional and Bioceramics, 2013
- Designing and evaluating transducers for narrowband ultrasonic spectroscopyNDT & E International, 2007
- Reconstruction of the normal velocity distribution on the surface of an ultrasonic transducer from the acoustic pressure measured on a reference surfaceAcoustical Physics, 2003
- Surface metrology using reflected ultrasonic signals in airUltrasonics, 2002
- Atmospheric absorption of sound: Further developmentsThe Journal of the Acoustical Society of America, 1995