Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Linas Svilainis has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of ultrasonic transducer response and structural integrity using coded photoacoustic imaging

    by Linas Svilainis, Andrius Chaziachmetovas, Luca De Marchi

  • Open Access

    Pulse Compression for Long Spread Spectrum Signals Application in Air-Coupled Ultrasonic Thickness Resonance Spectroscopy

    by Linas Svilainis, Muhammad Tayyib

    Interfering reflections occur due to air impedance mismatch from sample and transducer in non-contact resonance ultrasound spectroscopy (NC-RUS) measurements. The transducer is in close vicinity to the sample in order to ensure low attenuation in the air and flat wavefront. Therefore, interfering reflections are at 30-100 μs distance from the useful signal. Pulse excitation is used to avoid the overlap that can distort the measurement. A short pulse is required to ensure a broadband excitation, but such a pulse is low energy. Air-to-sample impedance mismatch further reduces signal energy and SNR. Therefore, very high voltage excitation and averaging is required. High voltage excitation increases nonlinearity effect in air, averaging increases measurement time. Long spread spectrum (SS) signals can achieve high SNR, avoid distortion in air, and expand the bandwidth available for analysis. However, long SS signals will overlap. Here it was demonstrated that the pulse compression (PuC) using matched filter is not suitable: the correlation sidelobes overlap with interfering reflections and bias errors of NC-RUS measurements increase. Solution proposed for PuC uses inverse filter. Such compressed signal corresponds to ideal pulse excitation (uniform spectrum) and has no sidelobes. If the spectral content of the SS needs to be preserved, then the PuC result can be gated and decompressed back. It was demonstrated that errors can be significantly reduced in such a case. For example, 0.008% sample density estimation bias error is achieved in case of 350 μs long excitation compared to 2.42% when using matched filter or 2.1% in case of mismatched filter, a 300 times reduction.


  • Open Access

    Air-coupled ultrasound transduction improvement using vertical piezoelements’ array

    by Linas Svilainis, Valdas Eidukynas, Luca De Marchi, Andrius Chaziachmetovas


  • Ca2+ delivery into cell suspension and spheroid models via ultrasound-induced inertial cavitation

    by Martynas Maciulevičius, Diana Ragaišė, Reda Rulinskaitė, Renaldas Raišutis, Linas Svilainis, Andrius Chaziachmetovas, Kristine Saleniece, Saulius Šatkauskas


  • Open Access

    Spectral Content Effects Study in Non-Contact Resonance Ultrasound Spectroscopy

    by Muhammad Tayyib, Linas Svilainis

    The application of spread-spectrum signals (arbitrary pulse width and position (APWP) sequences) in air-coupled resonant ultrasound spectroscopy is studied. It was hypothesized that spread-spectrum signal optimization should be based on te signal to noise ratio (SNR). Six APWP signal optimization criteria were proposed for this purpose. Experimental measurements were conducted using a thin polycarbonate sample using two standard spread-spectrum signals, linear and nonlinear frequency modulation, together with six optimized APWP signals. It was found that the performance of APWP signals derived from linear frequency modulation was better. The two best performing optimization criteria are SNR improvement on a linear scale with the SNR as an additional weight and energy improvement on a dB scale. The influence of spectral coverage on measurement errors was evaluated. It was found that it is sufficient to cover the sample resonance peak and the valley. The lowest error rates for density, 3%, and for thickness, 3.5%, were achieved when the upper valley was covered. For velocity, the best result, 5%, was achieved when the lower valley was covered. The lowest error rate for attenuation, 3.8%, was achieved in the case when both valleys were covered. Yet no significant performance degradation was noted when a whole −30 dB passband was covered.


  • Open Access

    Battery Powered Edge Computing Acceleration for Smart Agriculture Applications: A Use Case for Resonant Ultrasound Spectroscopy

    by Žilvinas Nakutis, Paulius Tervydis, Linas Svilainis, Alberto Rodríguez-Martínez

    Edge computing, using battery-powered devices, presents a viable solution for the real-time data processing for smart agriculture solutions. This paper explores the application of edge computing acceleration for smart agriculture, focusing on the use case of resonant ultrasound spectroscopy (RUS) for grape leaf analysis and monitoring. A methodology for estimating the utilization and performance of both edge and cloud data processing devices is proposed here. The effectiveness of edge and cloud data processing systems is analyzed in terms of data processing waiting time, cost, and battery life of edge devices as a function of intensity of data processing requests and load distribution in various scenarios. The analysis considers such factors as data processing capabilities, equipment cost, and energy consumption to provide insights into the optimal deployment of edge and cloud resources for smart agriculture applications, considering critical waiting and battery time criteria.


  • Open Access

    Self-Test of Air-Coupled Probe for Sensitivity Map Production Using Parabolic Reflector

    by Linas Svilainis, Jorge Camacho Sosa Dias, Darius Kybartas, Andrius Chaziachmetovas, Valdas Eidukynas

    Spatial distribution of a transduction efficiency over the air-coupled probe surface was proposed as a convenient tool for the probe integrity inspection. In this research, a parabolic reflector is used for passive focusing of the acoustic wave on the surface of inspected probe. Therefore, no additional transducer is required for inspection: probe is used for self-inspection. This approach allows to avoid the expensive focused transducer and replaces it by same type air coupled transducers as probe under test. Moreover, use of the parabolic mirror for focusing is frequency-independent, therefore such approach allows to inspect a wide range of the probes. Spread spectrum signals were used for excitation to improve the SNR and bandwidth coverage. Results of the experimental measurements of air-coupled transducer sensitivity map with natural and artificial defects implemented have been presented. Comparison with previously proposed techniques is given. It was found that defects presence distorts the focused beam, creating large sidelobes. Therefore sensitivity map obtained with proposed technique is lower quality than with previously proposed techniques. Beam profile measurements using a miniature microphone have been presented. Aperture-limiting mask has been proposed to reduce the sidelobes arising due to defects presence and resulting measurements quality has been improved.


  • Open Access

    Air-Coupled Ultrasound Spectroscopy Air Parameters Compensation Technique

    by Žilvinas Nakutis, Paulius Kaškonas, Dobilas Liaukonis, Linas Svilainis

    The air-coupled resonance ultrasound spectroscopy (RUS) of thin plate thickness, density, ultrasound velocity and attenuation measurement are affected by air parameters. If air parameters are left unaccounted errors will occur. Conventional thermometer measurements are not efficient because temperature can vary faster than temperature sensor response. Technique for air parameters estimation and compensation of the RUS inverse solution results is proposed. The ultrasound delay over known distance is used for velocity in air estimation. There is no need for the additional measurement: the propagation time between transducers can be obtained from RUS calibration measurement. Ultrasound velocity in air is then used for temperature estimation. These measurements are augmented by pressure sensor measurement for air density estimation. Evaluation of the attainable measurement errors and analysis of uncertainties under such compensation was carried out using simulated signals. Sensitivity coefficients for every parameter were derived and attainable errors evaluated for temperature range from -5 °C to +40 °C and atmospheric pressure range from 94 kPa to 105 kPa. It was concluded that the relative uncertainty of sample attenuation, ultrasound velocity attenuation, density and thickness could be reduced approximately 22 times compared to case when air parameters are assumed to be equal to those in normal conditions. Experimental verification used 2 mm polycarbonate plate, measured values were compared against reported data. Experiment confirmed the efficiency of the proposed compensation: thickness estimation bias errors were reduced 17 times, bias errors for density were reduced 15 times and velocity estimation bias errors were reduced 5 times.


  • Open Access

    The Assessment of Calcium and Bleomycin Cytotoxic Efficiency in Relation to Cavitation Dosimetry

    by Martynas Maciulevičius, Renaldas Raišutis, Baltramiejus Jakštys, Linas Svilainis, Andrius Chaziachmetovas, Saulius Šatkauskas

    Microbubble (MB)- and ultrasound (US)-facilitated intracellular Ca2+ delivery, known as sonoporation (SP), is a promising anticancer treatment modality, since it allows a spatio-temporally controllable and side-effect-free alternative to conventional chemotherapy. The current study provides extensive evidence that a 5 mM concentration of Ca2+ in combination with US alone or US and Sonovue MBs can be an alternative to the conventional 20 nM concentration of the anticancer drug bleomycin (BLM). Ca2+ application together with SP induces a similar level of death in Chinese hamster ovary cells to the combination of BLM and SP but does not cause systemic toxicity, as is inherent to conventional anticancer drugs. In addition, Ca2+ delivery via SP alters three vital characteristics essential for viable cells: membrane permeability, metabolic activity and proliferation ability. Most importantly, Ca2+ delivery via SP elicits sudden cell death—occurring within 15 min—which remains similar during 24–72 h and 6 d periods. The extensive study of US waves side-scattered by MBs led to the quantification of the cavitation dose (CD) separately for subharmonics, ultraharmonics, harmonics and broadband noise (up to 4 MHz). The CD was suitable for the prognostication of the cytotoxic efficiency of both anticancer agents, Ca2+ and BLM, as was indicated by an overall high (R2 ≥ 0.8) correlation (22 pairs in total). These extensive analytical data imply that a broad range of frequencies are applicable for the feedback-loop control of the process of US-mediated Ca2+ or BLM delivery, successively leading to the eventual standardization of the protocols for the sonotransfer of anticancer agents as well as the establishment of a universal cavitation dosimetry model.


  • Open Access

    Ultrasonic needle hydrophone calibration in air by a parabolic off-axis mirror focused beam using three-transducer reciprocity

    by Linas Svilainis, Andrius Chaziachmetovas, Paulius Kaskonas, Tomas E. Gomez Alvarez-Arenas