Tornado cleaning technique for food impaction in gastroduodenal stent using a high-rotational spiral basket catheter

Authors:

Abstract
Food impaction can cause endoscopic gastroduodenal stent (GDS) occlusion, requiring endoscopic cleaning [1] [2]. However, removing the residue stuck to the GDS lumen is often difficult. Recently, a novel basket catheter became available in Japan that is reportedly useful for removing bile duct stones [3] [4] [5]. This catheter comprises an eight-wire spiral basket connected to a rotating handle using a four-layer catheter shaft with a high torque response ([Fig. 1]). Herein, we report on an efficient GDS cleaning technique using this catheter ([Fig. 2], [Video 1]). A 63-year-old man who underwent a cholecystectomy for gallbladder cancer developed a gastric outlet obstruction (GOO) due to local recurrence involving the duodenal bulb. The GOO improved on performing endoscopic GDS placement (HANAROSTENT Naturfit; Boston Scientific, Marlborough, Massachusetts, USA) in the duodenal stenosis. However, frequent vomiting developed three weeks postoperatively. Computed tomography revealed residual fluid in the GDS lumen and a distended stomach; therefore, endoscopic re-intervention was performed. The stomach contained substantial residue, and the GDS was occluded because of food impaction. Water jet cleaning barely removed any food residue on the stent mesh. Consequently, we cleaned the GDS using a basket catheter (RASEN2; KANEKA Medical, Osaka, Japan) in a procedure we termed the “tornado cleaning technique” due to its rapid, spiral motion resembling a vortex. First, a guidewire was advanced through the GDS lumen, and the basket catheter was inserted into the GDS under guidewire guidance. Then, the basket catheter was rotated into the residue at a high speed, and the basket wires efficiently removed the residue. Most food residue was successfully removed, and the GDS lumen was re-opened. Following this procedure, the patient was able to eat without any adverse events. No additional intervention was required, and the patient was discharged. In conclusion, the tornado technique using the basket catheter is useful for rapidly and safely cleaning the GDS lumen. Endoscopy_UCTN_Code_TTT_1AO_2AL Article published online: 19 August 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany