TKTakehiko Koga

Takehiko Koga

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Takehiko Koga has a total of 181 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Safety of Endoscopic Ultrasound-Guided Biliary Drainage in Patients with Distal Malignant Biliary Obstruction with Large-Volume Ascites

    by Takehiko Koga, Yusuke Ishida, Akihisa Ohno, Ryota Sagami, Yoshitaka Nakamura, Makoto Hinokuchi, Kosuke Takahashi, Hidefumi Nishikori, Nao Fujimori, Yasuhisa Hiroshima, et al.

    Takehiko Koga, Yusuke Ishida, Akihisa Ohno, Ryota Sagami, Yoshitaka Nakamura, Makoto Hinokuchi, Kosuke Takahashi, Hidefumi Nishikori, Nao Fujimori, Yasuhisa Hiroshima, Hiroki Taguchi, Shinichi Hashimoto, Eisuke Ozawa, Hiroaki Tsuji, Naoaki Tsuchiya, Takanori Kitaguchi, Keisuke Matsumoto, Makoto Fukuyama, Tatsuro Nii, Fumihito Hirai. Gut and Liver -0001;0:. https://doi.org/10.5009/gnl260042

  • Open Access

    A long-scope technique for difficult intrahepatic bile duct puncture during endoscopic ultrasound-guided hepaticogastrostomy

    by Takehiko Koga, Yusuke Ishida, Keisuke Matsumoto, Makoto Fukuyama, Takanori Kitaguchi, Naoaki Tsuchiya, Fumihito Hirai

    During endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), the intrahepatic bile duct is conventionally punctured from the upper gastric body.[1] [2] However, puncture may be challenging because of anatomical conditions.[3] [4] [5] Herein, we report a long-scope EUS-HGS technique performed from the gastric antrum as a rescue option. An 89-year-old man with distal biliary obstruction caused by unresectable pancreatic cancer underwent transpapillary stenting, followed by endoscopic duodenal stenting for malignant duodenal obstruction. Subsequently, the patient developed acute cholangitis, and an endoscopic nasobiliary drainage tube was placed through the duodenal stent mesh ([Fig. 1]). Following resolution of the cholangitis, EUS-HGS was performed as an alternative biliary drainage route ([Video 1]). Video 1 A long-scope endoscopic ultrasound-guided hepaticogastrostomy technique as a rescue option when puncture from the conventional position is difficult. The B3 bile duct was visualized from the gastric body using an echoendoscope. Puncture using a 19-gauge needle proved difficult as the gastric wall and liver moved away from the scope tip. Puncture of the alternate B2 was considered; however, prominent blood vessels were present along the puncture line ([Fig. 2]). This patient had a cascade stomach, and preprocedural computed tomography revealed that the left hepatic lobe was near the gastric antrum ([Fig. 3]). The echoendoscope was therefore advanced into the antrum and positioned in a long-scope configuration. From this position, the proximal B3 was clearly visualized and punctured using a 19-gauge needle ([Fig. 4]). Following guidewire insertion, a 7-Fr plastic stent was successfully placed ([Fig. 5]). No intraoperative or postoperative adverse events occurred. The patient was discharged home 4 days after the procedure and was subsequently managed with best supportive care. The long-scope position used in this case facilitated secure access to the puncture site. This approach also improved procedural stability because the echoendoscope can be stabilized along the greater curvature of the stomach. Although further investigations are warranted to determine the optimal indications, this technique may expand the technical options for EUS-HGS in patients with the left hepatic lobe positioned close to the gastric antrum. Endoscopy_UCTN_Code_TTT_1AS_2AH Received: 23 March 2026 Accepted after revision: 19 July 2026 Article published online: 04 August 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

  • Open Access

    Benefit of multi-hole self-expandable metal stent placement for hilar biliary bleeding: effective hemostasis without biliary branch obstruction

    by Takehiko Koga, Keisuke Matsumoto, Yusuke Ishida, Yasuharu Shimoji, Mitsuhiro Kiya, Naoaki Tsuchiya, Fumihito Hirai

    Endoscopic retrograde cholangiopancreatography (ERCP) is an established approach for managing hemobilia associated with hepatobiliary malignancies, and hemostasis using a covered self-expandable metal stent (SEMS) has been reported [1] [2] [3]. However, in the case of hilar biliary bleeding, this approach may occlude adjacent biliary branches. Herein, we report a novel technique using a multi-hole SEMS (MHSEMS, [Fig. 1], [4] [5]) that achieves hemostasis while preserving biliary branches ([Video 1]). A 68-year-old man with gallbladder cancer and multiple liver metastases presented with jaundice and anemia. Computed tomography revealed high-density nodules within the bile duct, suggesting hemobilia due to bile duct invasion by a metastatic liver lesion ([Fig. 2]). ERCP revealed active bleeding from the duodenal papilla and filling defects on cholangiography ([Fig. 3]). The right hepatic duct was obstructed immediately above the hilum by metastatic invasion, whereas the left hepatic duct remained patent. After guidewire placement into the B8 bile duct, the MHSEMS (8 mm × 10 cm, HANAROSTENT Multi-Hole Benefit, M.I.Tech Co., Seoul, Korea) was deployed from B8 to the common bile duct across the left hepatic duct ([Fig. 4]). An endoscopic nasobiliary drainage (ENBD) tube was placed within the MHSEMS for monitoring. Post-procedural ENBD drainage was non-bloody, and follow-up cholangiography via the ENBD showed no filling defects and smooth contrast flow into the left hepatic duct through the MHSEMS ([Fig. 5]). The patient’s condition improved, and chemotherapy was resumed. Compared with the conventional covered SEMS, the MHSEMS has a smaller silicone-membrane contact area at the bleeding site but a lower risk of occluding the biliary branches. Although the safety of MHSEMS placement in the hilar region remains uncertain due to potential risks such as segmental cholangitis and early obstruction, the MHSEMS may provide an optimal balance between hemostasis and preservation of biliary drainage in selected cases of hilar biliary bleeding. Endoscopy_UCTN_Code_TTT_1AR_2AZ Article published online: 20 April 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany


  • Open Access

    Sphincterotomy during endoscopic biliary drainage in cholangitis with sepsis-induced coagulopathy increases bleeding without clinical benefits

    by Yasuhisa Hiroshima, Ryota Sagami, Naosuke Kuraoka, Tatsuya Noguchi, Yasusato Matsuda, Takero Terayama, Yoshifumi Azuma, Takao Sato, Hidefumi Nishikori, Hideho Honda, et al.

  • Open Access

    Effect of a self-assembling peptide hydrogel on delayed bleeding following endoscopic sphincterotomy: Prospective pilot cohort study

    by Yusuke Ishida, Naoaki Tsuchiya, Takehiko Koga, Takanori Kitaguchi, Keisuke Matsumoto, Makoto Fukuyama, Kaori Hata, Kei Nishioka, Noriko Shiga, Tsutomu Iwasa, et al.

    Endoscopic sphincterotomy (EST) is important in endoscopic retrograde cholangiopancreatography, but bleeding remains its common complication. This pilot study evaluated the efficacy and safety of a self-assembling peptide hydrogel (SAPH; PuraStat) in managing EST-related hemorrhage. A prospective cohort study was conducted from June 2023 to March 2024 at three hospitals in Japan, enrolling patients undergoing EST. Patients were divided into SAPH (received SAPH for EST-related bleeding) and control groups (patients without EST-related hemorrhage); primary endpoint was incidence of delayed bleeding. Of the 254 patients analyzed, 27 were in the SAPH group and 227 in the control group. Background factors related to bleeding were aligned using propensity score matching (PSM). Incidence of EST-related bleeding was 10.6% (27/254). In the SAPH group, 26 of 27 patients (96.3%) achieved successful hemostasis using SAPH alone. Although no delayed bleeding occurred in this group, it occurred in four patients in the control group (1.57%, 4/254). Other adverse events showed no significant difference between the groups. Results were similar to those after PSM and in the subgroup analysis excluding those with self-expandable metallic stent placement. SAPH is a simple, effective, and safe hemostatic option for treating EST-related hemorrhage and may be a promising first-line approach. This pilot study did not demonstrate a significant reduction in delayed bleeding, but absence of delayed bleeding in the SAPH group is noteworthy and suggests a potential preventive benefit. Thus, larger randomized controlled trials are warranted to validate these preliminary findings.


  • Open Access

    Safe retrieval of gastrointestinal foreign bodies using the novel endoscopic attachment with a flower-shaped design

    by Sara Haruki, Takehiko Koga, Norihiro Kojima, Hiroshi Takamori

    When performing the endoscopic retrieval of foreign bodies from the gastrointestinal tract, attaching a hood to the distal tip of the endoscope is necessary to ensure safe removal [1] [2] [3]. However, if a foreign body cannot be accommodated within the hood, the risk of gastrointestinal injury exists. Herein, we report a safe retrieval technique using a novel endoscopic distal attachment specifically designed for foreign body retrieval (EndoFlower; Fujifilm Medical Corporation, Tokyo, Japan). Case 1 ([Fig. 1]): A 75-year-old woman accidentally ingested a press-through package (PTP) sheet. Case 2 ([Fig. 2]): A 57-year-old woman accidentally ingested a fish-bone. Case 3 ([Fig. 3]): A 92-year-old woman had accidentally ingested a denture. In all cases, the foreign body was successfully retrieved using an endoscope equipped with a novel attachment, without causing any gastrointestinal injury ([Video 1]). The novel attachment is a dedicated foreign-body retrieval device composed of five silicone flaps in a flower-shaped design. This attachment has a total length of 20 mm and consists of five 20 × 30mm flaps ([Fig. 4]). During endoscope insertion, the flaps are folded opposite to the direction of scope advancement to avoid obstructing the visual field. Although esophageal inversion of the flaps is sometimes possible, it was difficult in the present three cases; therefore, they were inverted in the stomach to envelop the foreign body ([Fig. 5]). This attachment may be a safe and effective option for foreign body retrievals. Endoscopy_UCTN_Code_CCL_1AB_2AF Article published online: 09 March 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

  • Open Access

    Side-by-side plastic stent insertion for refractory post-endoscopic sphincterotomy bleeding after covered metal stent placement

    by Takehiko Koga, Naoaki Tsuchiya, Yusuke Ishida, Makoto Fukuyama, Keisuke Matsumoto, Yi-Ling Ko, Fumihito Hirai

  • Open Access

    Quadruple and quintuple transpapillary stenting without predilation for complex hilar biliary obstruction using a novel 7-Fr ultratapered plastic stent

    by Takehiko Koga, Makoto Fukuyama, Yusuke Ishida, Naoaki Tsuchiya, Keisuke Matsumoto, Yi-Ling Ko, Fumihito Hirai

    Management of hilar biliary obstruction (HBO) often requires transpapillary multistenting; however, the insertion of more than three stents into severe hilar biliary strictures remains technically challenging, even after predilation [1]. Recently, a novel 7-Fr ultratapered plastic stent (Crane stent, SB-KAWASUMI, Kanagawa, Japan) has shown high insertability in endoscopic ultrasound-guided drainage procedures [2] [3] [4] [5]. Given their structural advantages, we used ultratapered stents for transpapillary multistenting in two challenging HBO cases ([Video 1]). Patient 1 was an 81-year-old woman with hepatocellular carcinoma who developed HBO due to immune checkpoint inhibitor-induced sclerosing cholangitis. During the initial endoscopic retrograde cholangiopancreatography (ERCP), three 7-Fr plastic stents were placed in segments B2, B7, and B8 ([Fig. 1]); however, the patient subsequently developed segmental cholangitis in B3, necessitating reintervention. First, the previously placed stent in B2 was removed, and a 7-Fr plastic stent was placed in B3. The ultratapered stent was then selected as the fourth stent and was successfully inserted into B2 ([Fig. 2]). No dilation device was used at any stage of the procedure. Postoperatively, the patient’s cholangitis improved. Patient 2 was a 69-year-old man with unresectable gallbladder cancer who presented with HBO. Magnetic resonance cholangiopancreatography revealed isolation of tertiary bile duct branches. During the initial ERCP, 7-Fr plastic stents were placed in B3 and B8 ([Fig. 3]); however, his jaundice persisted, necessitating reintervention. After the previously placed stents had been removed, three 7-Fr plastic stents were placed in B2, B3, and B5. Subsequently, the ultratapered stents were selected as the fourth and fifth stents and were successfully inserted into B4 and B8 ([Fig. 4]). No dilation device was used at any stage of the procedure. The patient’s jaundice improved, enabling the subsequent initiation of chemotherapy. In both cases, more than three stents were successfully placed without predilation. The seamless transition between the guidewire, inner sheath, and stent tip in the ultratapered plastic stent system contributes to its excellent insertability ([Fig. 5]). This structural design may offer significant advantages for complex multistenting in cases of HBO. Endoscopy_UCTN_Code_TTT_1AR_2AZ Article published online: 20 August 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

  • Open Access

    Tornado cleaning technique for food impaction in gastroduodenal stent using a high-rotational spiral basket catheter

    by Takehiko Koga, Keisuke Matsumoto, Yi-Ling Ko, Makoto Fukuyama, Naoaki Tsuchiya, Yusuke Ishida, Fumihito Hirai

    Food impaction can cause endoscopic gastroduodenal stent (GDS) occlusion, requiring endoscopic cleaning [1] [2]. However, removing the residue stuck to the GDS lumen is often difficult. Recently, a novel basket catheter became available in Japan that is reportedly useful for removing bile duct stones [3] [4] [5]. This catheter comprises an eight-wire spiral basket connected to a rotating handle using a four-layer catheter shaft with a high torque response ([Fig. 1]). Herein, we report on an efficient GDS cleaning technique using this catheter ([Fig. 2], [Video 1]). A 63-year-old man who underwent a cholecystectomy for gallbladder cancer developed a gastric outlet obstruction (GOO) due to local recurrence involving the duodenal bulb. The GOO improved on performing endoscopic GDS placement (HANAROSTENT Naturfit; Boston Scientific, Marlborough, Massachusetts, USA) in the duodenal stenosis. However, frequent vomiting developed three weeks postoperatively. Computed tomography revealed residual fluid in the GDS lumen and a distended stomach; therefore, endoscopic re-intervention was performed. The stomach contained substantial residue, and the GDS was occluded because of food impaction. Water jet cleaning barely removed any food residue on the stent mesh. Consequently, we cleaned the GDS using a basket catheter (RASEN2; KANEKA Medical, Osaka, Japan) in a procedure we termed the “tornado cleaning technique” due to its rapid, spiral motion resembling a vortex. First, a guidewire was advanced through the GDS lumen, and the basket catheter was inserted into the GDS under guidewire guidance. Then, the basket catheter was rotated into the residue at a high speed, and the basket wires efficiently removed the residue. Most food residue was successfully removed, and the GDS lumen was re-opened. Following this procedure, the patient was able to eat without any adverse events. No additional intervention was required, and the patient was discharged. In conclusion, the tornado technique using the basket catheter is useful for rapidly and safely cleaning the GDS lumen. Endoscopy_UCTN_Code_TTT_1AO_2AL Article published online: 19 August 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany