Biometry and Interdevice Differences in Primary Angle-Closure Disease with Unilateral Zonulopathy: A Paired-Eye Study
Preprint
- 26 October 2026
- preprint
- Published by MDPI AG in Preprints.org
Abstract
Background/Objectives: To compare preoperative clinical and biometric characteristics between primary angle-closure disease (PACD) eyes with intraoperatively identified zonulopathy and their fellow eyes, and to explore interdevice measurement differences. Methods: This single-center paired-eye study included 57 patients with PACD undergoing bilateral cataract surgery and unilateral intraoperatively identified zonulopathy. Preoperative measurements were obtained using IOLMaster, Pentacam, and ultrasound biomicroscopy (UBM). Paired outcomes were compared using Wilcoxon signed-rank or exact McNemar tests, with Benjamini–Hochberg correction applied separately to clinical and biometric comparisons. Results: Eyes with zonulopathy more frequently had primary angle-closure glaucoma and previous acute angle-closure (AAC) attacks, greater angle-closure extent, and more severe mean deviation-based visual-field loss. These eyes had shallower corrected IOLMaster anterior chamber depth (ACD; 1.50 ± 0.40 versus 1.82 ± 0.35 mm), lower lens position (4.03 ± 0.33 versus 4.37 ± 0.28 mm), and smaller anterior chamber volume (59.9 ± 24.0 versus 75.4 ± 22.8 mm³; all q < 0.001). UBM minus IOLMaster ACD, UBM minus Pentacam ACD, and Pentacam minus UBM pupil diameter differed significantly between paired eyes (q = 0.002, 0.017, and 0.023, respectively). Conclusions: PACD eyes with occult zonulopathy showed a shallower anterior chamber, lower lens position, smaller anterior chamber volume, and greater interdevice differences in selected ACD and pupil measurements. These exploratory associations require validation before their use for preoperative identification of zonulopathy.Keywords
All Related Versions
This publication has 28 references indexed in Scilit:
- Zonular ligament abnormalities intermingled in acute primary angle closure: A diagnostic and therapeutic challengeHeliyon, 2024
- Zonular dialysis and cataract surgery: results from a UK tertiary eye care referral centreCanadian Journal of Ophthalmology, 2023
- Evaluation of Multimodal Biometric Parameters for Diagnosing Acute Angle Closure Secondary to Lens SubluxationOphthalmology and Therapy, 2022
- Advanced OCT Analysis of Biopsy-proven Vitreoretinal LymphomaAmerican Journal of Ophthalmology, 2021
- A Database Study of Visual Outcomes and Intraoperative Complications of Postvitrectomy Cataract SurgeryOphthalmology, 2018
- Factors Associated With Zonular Instability During Cataract Surgery in Eyes With Acute Angle Closure AttackAmerican Journal of Ophthalmology, 2017
- Pattern of Visual Field Loss in Primary Angle-Closure Glaucoma Across Different Severity LevelsOphthalmology, 2016
- Pretreatment Anterior Segment Imaging During Acute Primary Angle ClosureOphthalmology, 2014
- Imaging Zonular Abnormalities Using Ultrasound BiomicroscopyArchives of Ophthalmology (1950), 1998
- The Lens Opacities Classification System IIIArchives of Ophthalmology (1950), 1993