Siyuan Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Siyuan Liu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Baikai Ma
Department of Ophthalmology, Peking University Third Hospital, Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Beijing 100191, China, China
1 shared publication - Dehai Liu
Department of Ophthalmology, Peking University Third Hospital, Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Beijing 100191, China, China
1 shared publication - Lanxin Hu
Department of Ophthalmology, Peking University Third Hospital, Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Beijing 100191, China, China
1 shared publication - Qianqian Lan
Institute of Ophthalmic Diseases, Guangxi Academy of Medical Sciences, Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology, Department of Ophthalmology, the People's Hospital of Guangxi Zhuang Autonomous Region, Nanning, Guangxi Zhuang Autonomous Region, China, China
1 shared publication - Rui Qin
Department of Ophthalmology, Peking University Third Hospital, Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Beijing 100191, China, China
1 shared publication - Tong Sun
Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China
1 shared publication
Latest Publications
- Open Access
- 26 October 2026
- Published by MDPI AG in Preprints.org
Biometry and Interdevice Differences in Primary Angle-Closure Disease with Unilateral Zonulopathy: A Paired-Eye Study
Background/Objectives: To compare preoperative clinical and biometric characteristics between primary angle-closure disease (PACD) eyes with intraoperatively identified zonulopathy and their fellow eyes, and to explore interdevice measurement differences. Methods: This single-center paired-eye study included 57 patients with PACD undergoing bilateral cataract surgery and unilateral intraoperatively identified zonulopathy. Preoperative measurements were obtained using IOLMaster, Pentacam, and ultrasound biomicroscopy (UBM). Paired outcomes were compared using Wilcoxon signed-rank or exact McNemar tests, with Benjamini–Hochberg correction applied separately to clinical and biometric comparisons. Results: Eyes with zonulopathy more frequently had primary angle-closure glaucoma and previous acute angle-closure (AAC) attacks, greater angle-closure extent, and more severe mean deviation-based visual-field loss. These eyes had shallower corrected IOLMaster anterior chamber depth (ACD; 1.50 ± 0.40 versus 1.82 ± 0.35 mm), lower lens position (4.03 ± 0.33 versus 4.37 ± 0.28 mm), and smaller anterior chamber volume (59.9 ± 24.0 versus 75.4 ± 22.8 mm³; all q < 0.001). UBM minus IOLMaster ACD, UBM minus Pentacam ACD, and Pentacam minus UBM pupil diameter differed significantly between paired eyes (q = 0.002, 0.017, and 0.023, respectively). Conclusions: PACD eyes with occult zonulopathy showed a shallower anterior chamber, lower lens position, smaller anterior chamber volume, and greater interdevice differences in selected ACD and pupil measurements. These exploratory associations require validation before their use for preoperative identification of zonulopathy.
- 26 October 2026
- Published by MDPI AG in Preprints.org
Open AccessBiometry and Interdevice Differences in Primary Angle-Closure Disease with Unilateral Zonulopathy: A Paired-Eye Study
Background/Objectives: To compare preoperative clinical and biometric characteristics between primary angle-closure disease (PACD) eyes with intraoperatively identified zonulopathy and their fellow eyes, and to explore interdevice measurement differences. Methods: This single-center paired-eye study included 57 patients with PACD undergoing bilateral cataract surgery and unilateral intraoperatively identified zonulopathy. Preoperative measurements were obtained using IOLMaster, Pentacam, and ultrasound biomicroscopy (UBM). Paired outcomes were compared using Wilcoxon signed-rank or exact McNemar tests, with Benjamini–Hochberg correction applied separately to clinical and biometric comparisons. Results: Eyes with zonulopathy more frequently had primary angle-closure glaucoma and previous acute angle-closure (AAC) attacks, greater angle-closure extent, and more severe mean deviation-based visual-field loss. These eyes had shallower corrected IOLMaster anterior chamber depth (ACD; 1.50 ± 0.40 versus 1.82 ± 0.35 mm), lower lens position (4.03 ± 0.33 versus 4.37 ± 0.28 mm), and smaller anterior chamber volume (59.9 ± 24.0 versus 75.4 ± 22.8 mm³; all q < 0.001). UBM minus IOLMaster ACD, UBM minus Pentacam ACD, and Pentacam minus UBM pupil diameter differed significantly between paired eyes (q = 0.002, 0.017, and 0.023, respectively). Conclusions: PACD eyes with occult zonulopathy showed a shallower anterior chamber, lower lens position, smaller anterior chamber volume, and greater interdevice differences in selected ACD and pupil measurements. These exploratory associations require validation before their use for preoperative identification of zonulopathy.