On-Orbit Radiometric Performance of GF-7 Satellite Multispectral Imagery
Open Access
- 12 February 2022
- journal article
- research article
- Published by MDPI AG in Remote Sensing
- Vol. 14 (4) , 886
Abstract
China’s first civilian, sub-meter, high-resolution stereo mapping satellite, GF-7, launched on 3 November 2019. Radiometric characterization of GF-7 multispectral imagery has been performed in this study. A relative radiometric accuracy evaluation of the GF-7 multispectral imagery was performed using several large uniform scenes, and the results showed that the accuracy is better than 2%. The absolute radiometric evaluation of the GF-7 satellite sensor was conducted at the Baotou and Dunhuang calibration sites, using the reflectance-based vicarious approach. The synchronous measurements of surface reflectance and atmospheric parameters were collected as the input for the radiative transfer model. The official radiometrically calibrated coefficient of the GF-7 multispectral imagery was evaluated with the predicted top-of-atmosphere (TOA) radiance from the radiative transfer model. The results indicated that the absolute radiometric accuracy of GF-7 multispectral imagery is better than 5%. In order to monitor the radiometric stability of the GF-7 satellite multispectral sensor, a relative and absolute radiometric accuracy assessment campaign should be performed several times a year.Keywords
Funding Information
- National Key R&D Program of China (2018YFB0504800, 2018YFB0504801)
This publication has 25 references indexed in Scilit:
- Landsat-8 Operational Land Imager (OLI) Radiometric Performance On-OrbitRemote Sensing, 2015
- The Ground-Based Absolute Radiometric Calibration of Landsat 8 OLIRemote Sensing, 2015
- Radiometric Non-Uniformity Characterization and Correction of Landsat 8 OLI Using Earth Imagery-Based TechniquesRemote Sensing, 2014
- Landsat-8 Operational Land Imager Radiometric Calibration and StabilityRemote Sensing, 2014
- Permanent target for optical payload performance and data quality assessment: spectral characterization and a case study for calibrationJournal of Applied Remote Sensing, 2014
- In-flight absolute calibration of an airborne wide-view multispectral imager using a reflectance-based method and its validationInternational Journal of Remote Sensing, 2012
- Absolute radiometric calibration of the RapidEye multispectral imager using the reflectance-based vicarious calibration methodJournal of Applied Remote Sensing, 2011
- Radiometric characterization of IKONOS multispectral imageryRemote Sensing of Environment, 2003
- Absolute radiometric calibration of Landsat 7 ETM+ using the reflectance-based methodRemote Sensing of Environment, 2001
- Calibration of Space-Multispectral Imaging SensorsRemote Sensing of Environment, 1999