Laser-induced plasma imaging for low-pressure detection
- 8 June 2018
- journal article
- research article
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (12) , 15962-15971
Abstract
A novel technique based on laser induced plasma imaging is proposed to measure residual pressure in sealed containers with transparent walls, e.g. high voltage vacuum interrupter in this paper. The images of plasma plumes induced on a copper target at pressure of ambient air between 10−2Pa and 105Pa were acquired at delay times of 200ns, 400ns, 600ns and 800ns. All the plasma images at specific pressures and delay times showed a good repeatability. It was found that ambient gas pressure significantly affects plasma shape, plasma integral intensities and expansion dynamics. A subsection characteristic method was proposed to extract pressure values from plasma images. The method employed three metrics for identification of high, intermediate and low pressures: the distance between the target and plume center, the integral intensity of the plume, and the lateral size of the plume, correspondingly. The accuracy of the method was estimated to be within 15% of nominal values in the entire pressure range between 10−2Pa and 105Pa. The pressure values can be easily extracted from plasma images in the whole pressure range, thus making laser induced plasma imaging a promising technique for gauge-free pressure detection.Keywords
Funding Information
- China Scholarship Council (CSC)
- National Natural Science Foundation of China (NSFC) (51521065, 51777154)
This publication has 28 references indexed in Scilit:
- Background gas collisional effects on expanding fs and ns laser ablation plumesApplied Physics A, 2014
- Emission features and expansion dynamics of nanosecond laser ablation plumes at different ambient pressuresJournal of Applied Physics, 2014
- An Enhanced Vacuum Cure Technique for On-Aircraft Repair of Carbon-Bismaleimide CompositesApplied Composite Materials, 2010
- Influence of ambient gas pressure on laser-induced breakdown spectroscopy technique in the parallel double-pulse configurationSpectrochimica Acta Part B: Atomic Spectroscopy, 2004
- Carbon nanotube electron source based ionization vacuum gaugeApplied Physics Letters, 2004
- Thermalization of a UV laser ablation plume in a background gas: From a directed to a diffusionlike flowPhysical Review E, 2004
- High performance Pirani vacuum gaugeJournal of Vacuum Science & Technology A, 1995
- Reliability of a capacitance manometer in the range 2×10−4−5×10−6 TorrReview of Scientific Instruments, 1975
- Influence of diffusion on the measurement of low pressure with the McLeod vacuum gauge. Based on a paper by GaedeVacuum, 1963
- An improved Bourdon gaugeJournal of Scientific Instruments, 1934