Accuracy of Computer-Guided Template-Based Implant Surgery
- 10 September 2019
- journal article
- research article
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. Publish Ah (6) , 556-563
Abstract
The aim of this clinical study was to analyze the accuracy of computer-guided implant surgery. Assisted by computed tomography (CT)-based planning software and navigational templates, 16 patients successfully received 26 dental implants. Each implant parameter (a–d) was calculated based on superimposed preoperative and postoperative cone beam CT scans: (a) deviation at entry point; (b) deviation at apex; (c) angular deviation; and (d) depth deviation. Mean central deviation at implant entry point and apex was 0.91 mm (standard error [SE] = 0.11 mm; 95% confidence interval [CI]: 0.69–1.13) and 1.22 mm (SE = 0.11 mm; 95% CI: 0.99–1.45), respectively. Mean angulation deviation was 4.11 degrees (SE = 0.52 degrees; 95% CI: 3.04–5.17) and the average depth deviation was 0.65 mm (SE = 0.11 mm; 95% CI: 0.42–0.87). For the total number of implants placed, the maximum error was 2.34 mm at entry point, 2.71 mm at apex, 9.44 degrees in angular deviation, and 2.00 mm in depth deviation. Great accuracy was reached even in advanced cases with prior bone augmentation and complex traumas. This leads to the conclusion that particularly in advanced cases, computer-guided implantation can be beneficial.Keywords
This publication has 20 references indexed in Scilit:
- Accuracy of computer‐aided implant placementClinical Oral Implants Research, 2012
- Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow‐up of 5 yearsClinical Oral Implants Research, 2012
- A systematic review of the survival and complication rates of implant‐supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 yearsClinical Oral Implants Research, 2012
- Clinical advantages of computer‐guided implant placement: a systematic reviewClinical Oral Implants Research, 2012
- A systematic review on the accuracy and the clinical outcome of computer‐guided template‐based implant dentistryClinical Oral Implants Research, 2009
- Clinical Accuracy of 3 Different Types of Computed Tomography-Derived Stereolithographic Surgical Guides in Implant PlacementJournal of Oral and Maxillofacial Surgery, 2009
- A systematic review of the 5‐year survival and complication rates of implant‐supported single crownsClinical Oral Implants Research, 2007
- Hemorrhaging Associated With Endosseous Implant Placement in the Anterior Mandible: A Review of the LiteratureJournal of Periodontology, 2004
- Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiographyDentomaxillofacial Radiology, 2004
- A comparison of the diagnostic advantages of panoramic radiography and computed tomography scanning for placement of root form dental implantsClinical Oral Implants Research, 1994