CRClaudio Rostetter

Claudio Rostetter

*This is an algorithmically generated author record based on publicly available information.

Claudio Rostetter has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Daniel Zweifel

    Private Practice for Maxillofacial Surgery, Technikumstrasse 73, 8400 Winterthur, Switzerland

    1 shared publication
  • J. Abazi

    Department of Maxillofacial Surgery, Frauenklinikstrasse 24, 8091 Zurich, Switzerland

    1 shared publication
  • M. Bredell

    Private Practice for Maxillofacial Surgery, Technikumstrasse 73, 8400 Winterthur, Switzerland

    1 shared publication
  • M. Rücker

    Department of Maxillofacial Surgery, Frauenklinikstrasse 24, 8091 Zurich, Switzerland

    1 shared publication
  • Martin Rücker

    Professor and Head of Clinic of Cranio-Maxillo-Facial and Oral Surgery, University Hospital Zurich, Zurich, Switzerland

    1 shared publication
  • Michael Blumer

    Senior Physician, Clinic of Cranio-Maxillo-Facial and Oral Surgery, University Hospital Zurich, Zurich, Switzerland

    1 shared publication

Latest Publications

  • Precision of 30 guided implants in complex tumour situations

    by C. Rostetter, J. Abazi, T. Gander, M. Bredell, M. Rücker, S. Studer, D. Zweifel

  • Accuracy of Computer-Guided Template-Based Implant Surgery

    by Tobias Schelbert, Thomas Gander, Michael Blumer, Ronald Jung, Martin Rücker, Claudio Rostetter

    The aim of this clinical study was to analyze the accuracy of computer-guided implant surgery. Assisted by computed tomography (CT)-based planning software and navigational templates, 16 patients successfully received 26 dental implants. Each implant parameter (a–d) was calculated based on superimposed preoperative and postoperative cone beam CT scans: (a) deviation at entry point; (b) deviation at apex; (c) angular deviation; and (d) depth deviation. Mean central deviation at implant entry point and apex was 0.91 mm (standard error [SE] = 0.11 mm; 95% confidence interval [CI]: 0.69–1.13) and 1.22 mm (SE = 0.11 mm; 95% CI: 0.99–1.45), respectively. Mean angulation deviation was 4.11 degrees (SE = 0.52 degrees; 95% CI: 3.04–5.17) and the average depth deviation was 0.65 mm (SE = 0.11 mm; 95% CI: 0.42–0.87). For the total number of implants placed, the maximum error was 2.34 mm at entry point, 2.71 mm at apex, 9.44 degrees in angular deviation, and 2.00 mm in depth deviation. Great accuracy was reached even in advanced cases with prior bone augmentation and complex traumas. This leads to the conclusion that particularly in advanced cases, computer-guided implantation can be beneficial.