Claudio Rostetter
Claudio Rostetter has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Zweifel
Private Practice for Maxillofacial Surgery, Technikumstrasse 73, 8400 Winterthur, Switzerland
1 shared publication J. Abazi
Department of Maxillofacial Surgery, Frauenklinikstrasse 24, 8091 Zurich, Switzerland
1 shared publicationM. Bredell
Private Practice for Maxillofacial Surgery, Technikumstrasse 73, 8400 Winterthur, Switzerland
1 shared publicationM. Rücker
Department of Maxillofacial Surgery, Frauenklinikstrasse 24, 8091 Zurich, Switzerland
1 shared publicationMartin Rücker
Professor and Head of Clinic of Cranio-Maxillo-Facial and Oral Surgery, University Hospital Zurich, Zurich, Switzerland
1 shared publicationMichael Blumer
Senior Physician, Clinic of Cranio-Maxillo-Facial and Oral Surgery, University Hospital Zurich, Zurich, Switzerland
1 shared publication
Latest Publications
- 1 November 2020
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 58 (9) , e62-e66
Precision of 30 guided implants in complex tumour situations
- 1 November 2020
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 58 (9) , e62-e66
Precision of 30 guided implants in complex tumour situations
- 10 September 2019
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. Publish Ah (6) , 556-563
Accuracy of Computer-Guided Template-Based Implant Surgery
The aim of this clinical study was to analyze the accuracy of computer-guided implant surgery. Assisted by computed tomography (CT)-based planning software and navigational templates, 16 patients successfully received 26 dental implants. Each implant parameter (a–d) was calculated based on superimposed preoperative and postoperative cone beam CT scans: (a) deviation at entry point; (b) deviation at apex; (c) angular deviation; and (d) depth deviation. Mean central deviation at implant entry point and apex was 0.91 mm (standard error [SE] = 0.11 mm; 95% confidence interval [CI]: 0.69–1.13) and 1.22 mm (SE = 0.11 mm; 95% CI: 0.99–1.45), respectively. Mean angulation deviation was 4.11 degrees (SE = 0.52 degrees; 95% CI: 3.04–5.17) and the average depth deviation was 0.65 mm (SE = 0.11 mm; 95% CI: 0.42–0.87). For the total number of implants placed, the maximum error was 2.34 mm at entry point, 2.71 mm at apex, 9.44 degrees in angular deviation, and 2.00 mm in depth deviation. Great accuracy was reached even in advanced cases with prior bone augmentation and complex traumas. This leads to the conclusion that particularly in advanced cases, computer-guided implantation can be beneficial.
- 10 September 2019
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. Publish Ah (6) , 556-563
Accuracy of Computer-Guided Template-Based Implant Surgery
The aim of this clinical study was to analyze the accuracy of computer-guided implant surgery. Assisted by computed tomography (CT)-based planning software and navigational templates, 16 patients successfully received 26 dental implants. Each implant parameter (a–d) was calculated based on superimposed preoperative and postoperative cone beam CT scans: (a) deviation at entry point; (b) deviation at apex; (c) angular deviation; and (d) depth deviation. Mean central deviation at implant entry point and apex was 0.91 mm (standard error [SE] = 0.11 mm; 95% confidence interval [CI]: 0.69–1.13) and 1.22 mm (SE = 0.11 mm; 95% CI: 0.99–1.45), respectively. Mean angulation deviation was 4.11 degrees (SE = 0.52 degrees; 95% CI: 3.04–5.17) and the average depth deviation was 0.65 mm (SE = 0.11 mm; 95% CI: 0.42–0.87). For the total number of implants placed, the maximum error was 2.34 mm at entry point, 2.71 mm at apex, 9.44 degrees in angular deviation, and 2.00 mm in depth deviation. Great accuracy was reached even in advanced cases with prior bone augmentation and complex traumas. This leads to the conclusion that particularly in advanced cases, computer-guided implantation can be beneficial.